§ 1103.1406 — Design Criteria Used to Evaluate Site Plans and Projects
Toledo Municipal Code (2026 S-105: complete to June 30, 2026) · Toledo Municipal Code § 1103.1406
Corpus is an independent public-information project, not the official City of Toledo website. Stable reference: corpuslaw.us/code/d803fc5b-4f55-4a89-840f-9cacc5b74393
1103.1406 Design Criteria Used to Evaluate Site Plans and Projects.
In addition to the design standards contained in Chapter 1109, Design Standards, the following criteria apply. A. Relationship of Buildings to Site 1. The site shall be planned to accomplish a desirable transition between the building(s) and the streetscape to provide for adequate planting, safe pedestrian movement, and parking areas. 2. Parking areas shall be treated with decorative elements, building wall extensions, plantings, or other innovative means so as to screen parking areas from view from public ways. 3. The height and scale of each building shall be compatible with its site and existing (or anticipated) adjoining buildings. 4. Newly installed utility services, and service revisions necessitated by exterior alterations, shall be underground. 5. Newly proposed sidewalks within the public right-of-way shall be a minimum of five feet (5') in width. B. Building Setback and Height 1. The maximum allowed front setback shall be 10 feet from the right-of-way unless a public-private setback zone is provided. 2. If a public-private setback zone is provided a maximum front setback of 20 feet is allowed for up to 50 percent of the building frontage. Buildings on corner lots must comply with maximum building setback standards along all lot frontages. Single family and two-family residential uses are exempt from this requirement. 3. The minimum side yard and rear yard setbacks shall be as specified in the underlying zoning district. 4. The maximum building height shall be as specified in the underlying zoning district. C. Building Design 1. Building facades facing a Primary Street must incorporate a main entrance door on the primary street. 2. Building frontages that face Primary Streets and exceed a width of 50 feet must include vertical visual elements to break the plane of the building frontage. Such vertical elements must be spaced at regularly spaced intervals to provide visual interest along the entire building frontage. 3. All roof-mounted mechanical equipment must be screened from public view. The screening must be of a sufficient height to prevent persons located at the street level from viewing the screened items and a sight line analysis from at least 200 feet away must be submitted for review and approval. The design, colors and materials used in screening must be consistent with the architectural design of the building. 4. Grade level mechanical equipment shall be screened from adjoining residential parcels and from the right of way(s). All utilities shall be underground wherever possible. 5. Dumpsters and trash receptacles must be screened in accordance with Sec. 1108.0304(B), and located to the rear of the property. 6. For commercially used property at least 60 percent of each building façade along a Primary Street, between the height of 2 feet and 10 feet above the nearest sidewalk grade, must consist of clear, non-tinted, non-mirrored, and uncovered window glass permitting views of the building's interior to a depth of at least 4 feet. For building frontages other than those on Primary Streets, the window glass must continue for a minimum of 10 feet from the building corner. No exterior security bars or roll-down metal doors shall be allowed. This provision shall be reduced to at least 30 percent, of each building facade along a Primary Street, for the conversion of a residential building to a commercial use. This provision does not apply to buildings officially recognized as historic or those deemed eligible for listing in the National Register of Historic Places if the provision would result in a modification of the original historic appearance of the building. D. Building Materials Maintaining a consistent palette of materials is important to establishing continuity within the District and to improving the overall appearance of the District. Predominant building materials should be high quality. Exterior insulation and finish system (EIFS) materials and applications are prohibited, except where used to simulate an existing material and when 36 inches above grade and not within an entryway, and comprising less than 15% of the facade. The following are identified as acceptable for predominant exterior building materials: 1. Brick: Shall be standard modular brick with common tooled mortar joints. Un-tooled joints, distressed brick, or irregular shaped brick are prohibited. Brick color and texture shall be compatible with original brick facades in the Cherry Street corridor. 2. Materials with a brick-like appearance such as "Founder's Brick", or similar material. 3. Wood, it must be painted. 4. Materials with a wood-like appearance such as "Textured Cementitious Board", "Cement Board Siding", or similar material. 5. Smooth finished stone such as limestone or sandstone; color to be light to medium 'buff'. 6. Glass. 7. Building materials other than those listed above may be approved by the Plan Director, in consultation with Cherry Street Development Organization, in special cases such as building additions or building renovations, taking into consideration the predominant building materials existing on the building to be added to or renovated. 8. Predominant exterior building materials shall not include the following: (1) smooth-faced concrete block (2) smooth-faced tilt-up concrete panels (3) pre-fabricated steel panels (4) vinyl siding 9. The use of high-intensity colors, metallic colors, blacks or fluorescent colors is prohibited. Paint colors shall visually relate building elements to each other, as well as individual facades to each other. The colors chosen for any façade shall relate to the neighboring facades and to the blockscape as a whole. The placement of colors should be based on the existing hierarchy of detail: base, major and minor trim colors. The color of the upper wall surface and the storefront piers is the base color. A palette of suggested color schemes may be obtained from the CSDO. The color scheme for the building shall be reviewed and approved by the CSDO. (Ord. 8-14. Passed 1-2-14.)
Ask a question about Toledo law
Corpus searches the Toledo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
