1103.1606 Design Criteria Used to Evaluate Site Plans and Projects.
In addition to the design standards contained in Chapter 1109, Design Standards, the following criteria apply. A. Relationship of Buildings to Site 1. The site shall be planned to accomplish a desirable transition between the building(s) and the streetscape to provide for adequate planting, safe pedestrian movement, and parking areas. 2. Parking areas shall be treated with decorative elements, building wall extensions, plantings, or other innovative means so as to screen parking areas from view from public ways. 3. The height and scale of each building shall be compatible with its site and existing (or anticipated) adjoining buildings. 4. Newly installed utility services, and service revisions necessitated by exterior alterations, should be underground. 5. Sidewalks located in the public right-of-way shall be appropriate widths consistent with those of adjacent properties. 6. Newly proposed sidewalks within the public right-of-way shall be a minimum of five feet (5') in width. B. Building Setback and Height 1. The maximum allowed front setback shall be twenty (20) feet unless a public-private setback zone is provided. 2. Buildings on corner lots must comply with maximum building setback standards along all lot frontages. 3. The minimum side yard and rear yard setbacks shall be as specified in the underlying zoning district. 4. The maximum building height shall be as specified in the underlying zoning district. C. Building Design 1. Building facades facing a Principal Street (as described below) must incorporate a main entrance door on the principal street. Principal Streets located in the UpTown District shall consist of the Streets named after the Presidents, Collingwood Blvd, 11th, 14th & 17th Streets. 2. Building frontages that face Principal Streets and exceed a width of 50 feet must include vertical visual elements to break the plane of the building frontage. Such vertical elements must be spaced at regularly spaced intervals to provide visual interest along the entire building frontage. 3. The use of public artwork is encouraged and should be incorporated whenever possible. 4. Grade level mechanical equipment shall be screened from public view and all public right-of-ways. All utilities shall be underground wherever possible. 5. Roof-mounted mechanical equipment must be screened from public view. The screening must be of a sufficient height to prevent persons located at the street level from viewing the screened items and a sight line analysis from at least 200 feet away must be submitted for review and approval. The design, colors and materials used in screening must be consistent with the architectural design of the building. 6. Dumpsters and trash receptacles must be screened in accordance with Sec. 1108.0304(B), and located to the rear of the property. 7. For commercially used property at least 60 percent of each building façade along a Principal Street, between the height of 2 feet and 10 feet above the nearest sidewalk grade, must consist of clear, non-tinted, non-mirrored, and uncovered window glass permitting views of the building's interior to a depth of at least 4 feet. For building frontages other than those on Principal Streets, the window glass shall continue for a minimum of 10 feet from the Principal Street building corner. No exterior security bars or roll-down metal doors shall be allowed. This provision shall be reduced to at least 30 percent of each building facade along a Principal Street, for the conversion of a residential building to a commercial use. This provision does not apply to buildings officially recognized as historic or those deemed eligible for listing in the National Register of Historic Places if the provision would result in a modification of the original historic appearance of the building. 8. New buildings, stand alone and in-fill buildings, may be designed in a contemporary style but must be in harmony and compatible with the context of neighboring properties. D. Building Materials Maintaining a consistent palette of materials is important to establishing continuity within the District and to improving the overall appearance of the District. Predominant building materials should be high quality. Exterior insulation and finish system (EIFS) materials and applications are prohibited, except where used to simulate an existing material and when eight (8) feet above grade and not within an entryway, and comprising less than 15% of the frontage facing the principal street & all public right-of-ways. The following are identified as acceptable for predominant exterior building materials: 1. Brick: Shall be standard modular brick (4" x 8") with common tooled mortar joints (the UDARC may approve non-standard modular brick sizes and designs). Un-tooled joints, distressed brick, or irregular shaped brick are prohibited. Brick color and texture shall be compatible with original brick facades in the UpTown District, constructed prior to the 1940's. Brick of this period was commonly blond, yellow-blond, beige, or dull red with very little color range. Textures varied from smooth or glazed to rough. Textures tended to be uniform. 2. Materials with a brick-like appearance (4" x 8") such as "Founder's Brick" or similar material (the UDARC may approve additional sizes and designs). 3. Wood; and it must be painted or stained/sealed. 4. Materials with a wood-like appearance such as "Textured Cementitious Board", "Cement Board Siding", or similar material. 5. Smooth finished or manufactured stone such as limestone or sandstone and terra cotta. 6. Glass. 7. Building materials other than those listed above may be approved by the Plan Director, in consultation with UDARC, in special cases such as building additions or building renovations, taking into consideration the predominant building materials existing on the building to be added to or renovated. 8. Predominant exterior building materials shall not include the following: a. smooth-faced concrete block b. smooth-faced tilt-up concrete panels c. pre-fabricated steel panels d. vinyl siding 9. The use of high-intensity colors, metallic colors, blacks or fluorescent colors is discouraged. Paint colors shall visually relate building elements to each other, as well as, individual facades to each other. The colors chosen for any façade shall relate to the neighboring facades and to the blockscape as a whole. The placement of colors should be based on the existing hierarchy of detail: base, major and minor trim colors. The color of the upper wall surface and the storefront piers is the base color. E. Alley Facades 1. On any building being considered for restoration or renovation, the exterior facades facing an alley shall also be improved. Any exterior fire escape that is still in use and approved by the Fire Prevention Division of the Department of Fire and Rescue Operations shall be repaired and painted. Unused fire escapes shall be removed completely. All unused sign brackets or mounting devices shall be removed. All existing doors, windows and security devices shall be repaired and painted or replaced. All masonry or other facade materials shall be cleaned and sealed or painted. New lighting and building identification signage or street addresses shall be installed. New lighting fixtures with downward directed lighting shall be installed above or near any point of entry into the building. 2. The use of artwork is encouraged along alley facades. (Ord. 530-15. Passed 10-27-15.)
Ask a question about Toledo law
Corpus searches the Toledo sections it holds and shows the ones that match, with their citations. Free, no sign-in.