1104.0903 General Requirements.
A. Canopies shall be set back a minimum of 10 feet from the property line, and shall be designed to be consistent with the building materials and colors of the principal building. Support columns shall be brick, brick base, or other durable materials compatible with the principal building. The Planning Director may require a peaked roof to complement the principal building. B. Pump islands shall be set back a minimum of 15 feet from the property line. C. Non-petroleum displays must be within 25 feet of the building but not within 25 feet of any right-of-way. The maximum height of such displays shall not exceed 5 feet. D. Free air (with the capability of filling standard automobile tires), water, and restrooms shall be provided and maintained during operating hours of the station. (Ord. 198-11. Passed 4-19-11.)