§ 1106.0205 — Setbacks
Toledo Municipal Code (2026 S-105: complete to June 30, 2026) · Toledo Municipal Code § 1106.0205
Corpus is an independent public-information project, not the official City of Toledo website. Stable reference: corpuslaw.us/code/595ffecc-24bd-47a1-9748-cc8ef4623209
1106.0205 Setbacks.
A. Measurement. Setbacks must be unobstructed from the ground to the sky except as otherwise expressly allowed in this subsection. Some exceptions are allowed. (See Section 1106.0205E.) B. Front Setbacks. 1. Measurement. Front setbacks extend the full width of a lot and are measured from the street or place right-of-way line. 2. Double-Frontage Lots. Double-frontage lots must provide a front setback on both streets. 3. Corner Lots. Where front setbacks have been established or are required on each of two intersecting streets, a front setback must be provided on each lot frontage of the corner lot, with the following two exceptions: a. In Residential districts, where the required front setback exceeds 25 feet, only one front setback in excess of 25 feet is required by this Zoning Code. b. The building width of a lot of record need not be reduced to less than 28 feet when the owner of such lot can show that ownership and control of any adjacent lot or lots of record are by another person. Under this provision, no structure shall be constructed closer than 10 feet to a right-of-way without review and approval from the Board of Zoning Appeal, unless specified in Sec. 1106.0100. (Ord. 276-13. Passed 5-28-13.) [image omitted; see the official code] 4. Contextual Front Setbacks. Regardless of the minimum front setback requirements imposed by the zoning district standards in this Chapter, applicants shall be allowed to use a Contextual Front Setback. A Contextual Front Setback may fall at any point between the required front setback and the front setback that exists on a lot that is nearest and oriented to the same street as the subject lot. If the subject lot is a corner lot, the Contextual Setback may fall at any point between the required front setback and the front setback that exists on the lot that is nearest and oriented to the same street as the subject lot. If all lots on the block face of the subject lot are vacant, the setback that is required by the zoning district shall apply. a. In no case shall the setback resulting from this provision exceed any applicable maximum setback in the Commercial Districts Intensity and Dimensional Standards Table, Section 1106.0102. b. Enclosed porches extending into a setback will not be considered part of the structure in determining the Contextual Front Setback. C. Side Setbacks. 1. Side setbacks extend from the front setback line to the rear setback line and are measured from the side lot line. If no front, or rear, setback is required, the required setback area must run to the opposite lot line. 2. Side setbacks on through lots must run the full length of the lot between front lot lines. 3. The side setback of a corner lot is on the side opposite of the lot frontage without the address. 4. Whenever the wall of any building, principal or accessory, exceeds 50 feet in length adjacent to the side lot line of a residential zoning district, the required setback for the building must be increased by 1 foot for each 10 feet of wall length or fraction thereof beyond 50 feet, provided that the required setback need not exceed 50 feet. 5. For nonconforming lots see Section 1114.0400. D. Rear Setbacks. 1. Rear setbacks extend the full width of the lot and are measured from the rear lot line. 2. The rear setback of a lot with more than one lot frontage is on the side of the lot opposite the lot frontage with the address. E. Permitted Exceptions to Setback Standards. The following features may project in required setbacks to the extent indicated: 1. Sills, belt courses, cornices, eaves and ornamental features not to exceed 12 inches; 2. Satellite dishes are allowed within rear setbacks, subject to the standards of Section 1105.0700; 3. Terraces, uncovered porches and ornamental features that do not extend more than 3 feet above the ground, provided they are set back at least 2 feet from side lot lines; 4. Enclosed balconies, enclosed fire escapes, accessibility ramps, accessibility lifts, unenclosed porches or metal awnings may project into a front or rear setback by up to 10 feet, or into a side setback for up to 3 feet, provided that a porch with jalousies or windows will be considered an enclosed porch (see Sec. 1111.1801D for enclosure of front porches); and 5. Enclosed vestibules containing not more than 40 square feet may project into a front setback by up to 4 feet. (Ord. 170-04. Passed 3-23-04.) 6. Air conditioner condensing units may be placed within the required side yard setback but must be setback at least one (1) foot from the side lot line. (Ord. 589-07. Passed 9-4-07.) 7. Whenever a lot abuts upon or adjoins an alley, one half of the alley width may be considered as a portion of the required rear yard setback. 8. The Plan Director may grant further exceptions to setback standards where the setback is needed to accommodate a person's disability for accessibility ramps and accessibility lifts. (Ord. 198-11. Passed 4-19-11; Ord. 193-16. Passed 5-24-16.)
Ask a question about Toledo law
Corpus searches the Toledo sections it holds and shows the ones that match, with their citations. Free, no sign-in.