For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 1305.02 — Permits: when not required

Toledo Municipal Code (2026 S-105: complete to June 30, 2026) · Toledo Municipal Code § 1305.02

Corpus is an independent public-information project, not the official City of Toledo website. Stable reference: corpuslaw.us/code/945e5721-c005-4b09-825d-a2021549b5cc

1305.02 Permits: when not required.

No permit shall be required for maintenance, work listed below at subsections (a) and (b), or any other work as described in Ohio Building Code 102.10 Work Exempt From Approval and Residential Code of Ohio 102.10 Work Exempt From Approval. Exemptions from obtaining a permit required by this Building Code shall not be construed as to authorize any work to be performed in violation of any applicable codes or any other provision in this Part Thirteen - Building Code. (a) For residential properties, provided that the work is done in accordance with all other applicable provisions, approval shall not be required for the following work: (1) Buildings: A. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed two hundred square feet (18.58 m2) and playground structures. B. Fences not over six feet (1829 mm) high. C. Retaining walls which are not over four feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge. D. Water tanks supported directly upon grade if the capacity does not exceed five thousand gallons (18 927 L) and the ratio of height to diameter or width does not exceed two to one. E. Sidewalks and driveways not more than thirty inches (762 mm) above grade and not over any basement or story below and which are not part of an accessible route. F. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. G. Swings and other playground equipment accessory to a one, two, or three-family dwelling. H. Window awnings supported by an exterior wall which do not project more than fifty-four inches (1372 mm) from the exterior wall and do not require additional support. I. Decks not exceeding 200 square feet (18.58 m2) in area, that are not more than 30 inches (762 mm) above grade at any point, are not attached to a dwelling, and do not serve as the exit door. J. Above-ground storage tanks as defined in rule 4101:8-2-01 of the Ohio Administrative Code and the associated tank foundations. K. Battery operated smoke or carbon monoxide alarms installed in existing buildings where no construction is taking place. (2) Electrical: A. Listed cord-and-plug connected temporary decorative lighting. B. Reinstallation of attachment plug receptacles but not the outlets thereof. C. Replacement of branch circuit overcurrent devices of the required capacity and type in the same location. D. Electrical wiring, devices, appliances, apparatus, or equipment operating at less than 25 volts and not capable of supplying more than 50 watts of energy. E. Repairs and Maintenance, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. F. Process equipment and the associated wiring on the load side of the power disconnect to the equipment. G. Electrical wiring equipment not connected to building services equipment in and adjacent to natural or artificially made bodies of water as defined in Article 682 of NFPA 70. (3) Gas: A. Portable heating, cooking, or clothes drying appliances. B. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. C. Portable fuel cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. D. Gas distribution piping owned and maintained by public or municipal utilities and located upstream of the point of delivery. E. Process equipment, including the associated tanks, foundations, and process piping. For combination building services/process or power piping systems, the power or process piping located downstream of the control valve which separates the process from the building services piping is exempt from approval. (4) Mechanical: A. Portable heating appliances. B. Portable ventilation equipment. C. Portable cooling units. D. Steam, hot or chilled water piping within any heating or cooling equipment regulated by the Residential Code of Ohio. E. Replacement of any part that does not alter approval of equipment or make such equipment unsafe. F. Portable evaporative cooler. G. Self-contained refrigeration systems containing ten pounds (4.54 kg) or less of refrigerant or that are actuated by motors of one horsepower (746 W) or less. H. Portable fuel cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. I. Heating and cooling distribution piping owned and maintained by public or municipal utilities. J. Process equipment including the associated tanks, foundations, and process piping. For combination building services/process or power piping systems, the power or process piping located downstream of the control valve which separates the process from the building services piping is exempt from approval. (5) Plumbing: A. The repair of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any concealed trap, drain-pipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and an approval shall be obtained and inspection made as provided in the Residential Code of Ohio. B. The clearance of stoppages or the repair of leaks in pipes, valves or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement of more than one fixture or rearrangement of valves, pipes or fixtures. C. Process equipment including the associated tanks, foundations, and process piping. For combination building services/process or power piping systems, the power or process piping located downstream of the control valve which separates the process from the building services piping is exempt from approval. (b) For all other properties, provided that the work is done in accordance with all other applicable provisions, approval shall not be required for the following work: (1) Buildings: A. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 120 square feet (11.15 m2) and playground structures. B. Fences not over 7 feet (2134 mm) high. C. Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or III-A liquids. D. Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons (18 927 L) and the ratio of height to diameter or width does not exceed two to one. E. Sidewalks, parking lots and driveways not more than 30 inches (762 mm) above grade, not over any basement or story below, and not part of an accessible route. F. Finishes not regulated by this code, decorating, or other work defined as maintenance or minor repair. G. Temporary motion picture, television and theater stage sets and scenery. H. Window awnings supported by an exterior wall of Group R-3. I. Tents and membrane structures exempted in Ohio Building Code Section 3103.1.3. J. Above-ground storage tanks as defined in rule 4101:1-2-01 of the Administrative Code and the associated tank foundations. K. Battery-operated smoke or carbon monoxide alarms installed in existing buildings where no construction is taking place. L. Battery-operated smoke or carbon monoxide alarms installed in existing buildings where no construction is taking place. M. Signs painted directly on building surfaces. N. Temporary yard signs. O. Signs not more than 21/2 square feet in area (0.23 m2). P. Signs required in accordance with the provisions of Ohio Building Code, Chapter 11. Q. Signs undergoing minor repairs in accordance with Ohio Building Code Section 102.10.2. S. Temporary or time-limited occupancy of a building used or constructed to respond to conditions directly connected to an emergency declaration issued by the governor or federal government. (c) Electrical: (1) Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. (2) Electrical equipment used for radio and television transmissions except equipment and wiring for power supply, and the installations of towers and antennas. (3) The installation of any temporary system required for the testing or servicing of electrical equipment or apparatus. (4) Electrical wiring, devices, appliances, apparatus or equipment operating at less than 25 volts and not capable of supplying more than 50 watts of energy, unless specifically addressed in the Ohio Building Code. (5) Process equipment and the associated wiring on the load side of the power disconnect to the equipment. (6) Electrical wiring equipment not connected to building services equipment in and adjacent to natural or artificially made bodies of water as defined in Article 682 of NFPA 70. (d) Gas: (1) Portable heating appliances. (2) Replacement of any part that does not alter approval of equipment or make such equipment unsafe. (3) Gas distribution piping owned and maintained by public or municipal utilities and located upstream of the point of delivery. (4) Process equipment, including the associated tanks, foundations, and process piping. For combination building services/process or power piping systems, the power or process piping located downstream of the control valve that separates the process from the building services piping is exempt from approval. (5) When installed by the servicing gas supplier, replacement of existing LP-gas containers by servicing gas supplier of the same capacity in the same location and associated regulators. (e) Mechanical: (1) Portable heating appliances. (2) Portable ventilation equipment. (3) Portable cooling units. (4) Replacement of any part of an appliance that does not alter its approval or make it unsafe. (5) Portable evaporative cooler. (6) Process equipment, including the associated tanks, foundations, and process piping. For combination building services/process or power piping systems, the power or process piping located downstream of the control valve that separates the process from the building services piping is exempt from approval. (7) Heating and cooling distribution piping installed and maintained by public or municipal utilities. (8) Self-contained refrigeration system containing 10 pounds (4.54 kg) or less of refrigerant and actuated by motors of 1 horsepower (0.75 kW) or less. (f) Plumbing: (1) The repair of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work is to be considered as new work and an approval is to be obtained and inspection made as provided in the Ohio Building Code. (2) The clearance of stoppages or the repair of leaks in pipes, valves or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve the replacement of more than one fixture or rearrangement of valves, pipes or fixtures. (3) Process equipment, including the associated tanks, foundations, and process piping. For combination building services/process or power piping systems, the power or process piping located downstream of the control valve that separates the process from the building services piping is exempt from approval. (1952 Code § 10-1-3.101; Ord. 122-15. Passed 3-31-15; Ord. 444-18. Passed 10-23-18; Ord. 361-25. Passed 9-9-25.)

Ask a question about Toledo law

Corpus searches the Toledo sections it holds and shows the ones that match, with their citations. Free, no sign-in.