For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13.16.150 — Industrial Wastewater Discharge Permit

Code of Ordinances of the City of Edmond, Oklahoma (Codified through Ordinance No. 4097, enacted August 10, 2026 (Supp. No. 40)) · Edmond Code of Ordinances tit. 13, § 13.16.150

Corpus is an independent public-information project, not the official City of Edmond website. Stable reference: corpuslaw.us/code/bd897f93-d356-416d-9bce-6f60de05c06e

13.16.150 - Industrial Wastewater Discharge Permit.

A. It is the purpose of this permit to provide for the recovery of costs from users of the City's wastewater disposal system for the implementation of the City of Edmond's Industrial Wastewater Treatment Program. B. Industrial Sewer User Charges. 1. The surcharge for industrial users shall be calculated and imposed according to the following schedule; subject to revision by the Edmond City Council. The surcharge is sixty-two cents ($0.62) per one (1) million gallons for each milligram per liter (mg/L) of B.O.D. in excess of two hundred fifty milligrams per liter (250 mg/L), and thirty-six cents ($0.36) per one (1) million gallons for each milligram per liter (mg/L) of suspended solids in excess of three hundred milligrams per liter (300 mg/L). 2. Schedule of Fees. Item | Schedule of Fees | Annual Cost A. | Categorical Pollutant Discharge (New) | $500.00 B. | Categorical Pollutant Discharge Permit (Renewal-Existing, Modified) | $250.00 C. | Non-Categorical Pollutant Discharge Permit (New) | $ 50.00 D. | Non-Categorical Pollutant Discharge Permit (Renewal-Modified) | $ 25.00 E. | Filing Appeals | $ 25.00 F. | Categorical Pollutant Permit (Potential to Discharge-New) | $250.00 G. | Categorical Pollutant Permit (Potential to Discharge-Renewal, Modified) | $125.00 H. | Private Water/Sewer Meter Inspection (Verify/Reverification) | $ 50.00 I. | Emergency Industrial Waste Disposal Inspection | $ 50.00 J. | Requested Categorical Pretreatment Facility Inspection | $ 50.00 3. The City may adopt additional charges and Fees for (1) consistent removal by the City of pollutants otherwise subject to Federal Pretreatment Standards, and (2) other fees as the City may deem necessary to carry out the requirements of the Treatment Program. C. Discharge Limits: 1. Permittee's Discharge Limits (a) The quality of the permittee's industrial discharges will be limited by General Pretreatment Regulations set forth in Federal Pretreatment Regulations which include the following numerical limitations: Pollutant or Pollutant Property | Maximum Allowable Concentration, mg/L | Average Concentration and/or Load mg/L or lb/day pH | 5.0-10.5 std units | 5.0-10.5 std units Oil & Grease (Petroleum Based) | 100 mg/L | 100 mg/L Benzene | 0.0 | n/a Toluene | 0.0 | n/a Xylene | 0.0 | n/a Ethyl Benzene | 0.0 | n/a Lead | .4 mg/L | .4 mg/L (b) Flow—Flow shall not exceed 25,000 gpd during any twenty-four (24) hour period without written permission from the Permitting Authority. (c) Specific Pollutant Limitations Permittee is not authorized to discharge (1) Any waters or wastes having pH lower than 5.5, or higher than 9.5, or other corrosive property capable of causing damage or hazard to structures, equipment, and personnel of the waste water treatment facilities. (2) Solid or viscous substances in quantities or of such size capable of causing obstruction to the flow in sewers, or other interference with the proper operation of the waste water treatment facilities such as, but not limited to, ashes, cinders, sand, mud, straw, shavings, metal, glass, rags, feathers, tar, plastics, wood, unground garbage, whole blood, manure, hair and fleshings, entrails, and paper dishes, cups, milk, containers, etc., either whole or ground by garbage grinders. (3) Any liquid or waste containing fats, wax, or oil, whether emulsified or not, in excess of 100 mg/l or containing substances which may solidify or become viscous at temperatures between 32° and 150°F. (0° to 65°C). (4) Any liquid or vapor having temperature higher than 150°F. (65°C). (5) Any waters or wastes containing strong acid or pickling wastes or concentrated plating solutions whether neutralized or no. (6) Any waters or wastes containing iron, chromium, copper, zinc, and similar objectionable or toxic substances; or wastes exerting in excessive chlorine requirements, to such degree that any such material received in the composite sewage at the waste water treatment facilities exceeds the limits established by the State Department of Public Health for such materials. (7) Any radioactive wastes or isotopes of such half life or concentration as may exceed the limits established by the State Department of Public Health in compliance with applicable State or federal regulations. (8) Any waters or wastes containing phenols or other taste or odor producing substances, in such concentrations exceeding limits which may be established by the State Department of Public Health, after treatment of the composite sewage, to meet the requirements of the State, Federal, or other public agencies with jurisdiction for such discharge into the receiving waters. (9) Materials which exert or cause (a) unusual concentrations of inert suspended solids (such as, but not limited to, Fuller's earth, lime slurries, and lime residue(s) or of dissolved solids (such as, but not limited to, sodium sulphate); (b) excessive discoloration (such as, but not limited to, die wastes and vegetable canning solutions); (c) unusual BOD chemical oxygen demand (COD), or chlorine requirements in such quantities as to constitute a significant load on the waste water treatment facilities; (d) unusual volume of flow or concentration of wastes constitution "slugs" as defined herein. (10) Waters or wastes containing substances which are not amenable to treatment or reduction by the sewage treatment processes employed, or are amenable to treatment only to such degree that the sewage treatment plant effluent cannot meet the requirements of other agencies having jurisdiction over discharge to the receiving waters. (11) Discharge of the following materials (in concentrations higher than that normally found in the potable water supply) into the sewage system is prohibited: antimony, arsenic, barium, beryllium, bismuth, boron, cadmium, chromium, cobalt, copper, iron, lead, manganese, mercury, molybdenum, nickel, rhenium, selenium, silver, strontium, tellurium, tin, uranyul ion, zinc. D. Applications. Any person desiring an Industrial Wastewater Discharge Permit shall make application to the City Clerk and shall pay said fees as set out above. (Ord. 2058, September 1993).

Ask a question about Edmond law

Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.