5.16.190 - Incinerators.
(a) Permit Required. No person shall install or make any alteration or modification to an incinerator which affects the emission of air contaminants without first having obtained a permit from the City Clerk and paying the fee of twenty-five dollars. (b) Application. A person making application for a permit shall furnish such information concerning the incinerator as the director may request including the plans, specification, manufacturer's descriptive literature and these reports. (c) Specifications. All incinerators installed after the effective date of the ordinance codified in this chapter shall be multiple chambered, gas fired in the primary and secondary chamber, and water scrubbed. All incinerators shall have a capacity of seventy-five pounds per hour or greater provided that this capacity shall not be applicable to incinerators designed and used exclusively as pathological incinerators. An incinerator of different construction may be used when the director determines that the incinerator will be equally effective in controlling the emission of air contaminants and approves its installation. (d) Operation. All incinerators shall be maintained and operated according to good practices. (e) Emission of particulate matter. Incinerators with a maximum burning capacity of two-hundred pounds per hour or more shall not emit particulate matter in excess of 0.2 grains per dry cubic foot corrected to twelve percent CO 2 of exhaust gas under standard conditions. Incinerators with a maximum burning capacity of less than two-hundred pounds per hour shall not emit particulate matter in excess of 0.3 grains per dry cubic foot corrected to twelve per cent CO 2 of exhaust gas under standard conditions. (f) Existing incinerators, exceptions. Within twelve months after the effective date of the ordinance codified in this chapter all existing incinerators shall comply with all provisions of this chapter except Section 5.16.190 (c). (g) Dense smoke, exception. Incinerators may emit dense smoke not exceeding a shade or the equivalent opacity of the shade designated as No. 2 on the Ringelmann Chart for periods not exceeding five minutes in any sixty minute period and not exceeding twenty minutes in any twenty-four hours period. (Ord. 594, 1970).
Ask a question about Edmond law
Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.