Sec. 13-70. - Methods for calculating stream flow and runoff.
The maximum condition of rainfall for a one hundred-year interval shall be used for the purposes of determining all runoff for the sizing of drainage channels and structures for the Midwest City Drainage Area, unless otherwise specified herein. Values used in formulas for runoff and size of drainage structures shall reflect the degree of urbanization set forth in the projected land use pattern contained in the general plan for the city. The following formulas and values shall be used for calculating all stream flow and runoff for the policies and regulations established herein: (1) Runoff from all drainage areas of three hundred twenty (320) acres or less shall be determined by the Rational Method or SCS TR-55 graph or chart method. Q = Air In which: Q = Flow in cubic feet per second. A = Area to be drained in acres, determined by field surveys for areas less than two hundred (200) acres, and, by latest government quadrangle maps for larger areas. I = Percent of imperviousness of the area; may vary between seventy (70) percent and ninety-eight (98) percent. Coefficients lower than these indicated values may be used; however, in such instances, individual block calculations will be submitted with plans. R = Rate of rainfall over entire drainage area in inches per hour, based on Oklahoma Depart of Transportation's Drainage Manual Intensity, Duration and Frequency Table for Zone II. (A copy of this table is available in the city engineer's office.) Runoff from all drainage areas in excess of three hundred twenty (320) acres shall be determined by the unit hydrograph method as detailed in Section 11 of SCS TR-55 or other methods of accepted engineering principles as approved by the city engineer. If detention is required the design shall be as shown in Chapter 11 of American Public Works Association "Special Report Number 49, Urban Stormwater Management" or other methods of accepted engineering principles as approved by the city engineer. (2) The size of closed storm sewers, open channels, culverts, and bridges shall be determined by using the Manning Formula, up to five hundred (500) acres, or HEC Tables or other methods of accepted engineering principles as approved by the city engineer. Q = [1.486*r⅔*s½*A] n In which: Q = Discharge in cubic feet per second. A = Cross-sectional area of water in conduit in square feet. r = Hydraulic radius of water in conduit. s = Mean slope of hydraulic gradient in feet of vertical rise per foot of horizontal distance. n = Roughness coefficient based on condition and type of material of conduit lining, but not less than 0.013. When using Manning's the storm sewer sizing shall be checked by use of inlet and outlet nomographs. The storm sewer shall be so as to maintain hydraulic grade line below the ground and/or gutter elevations to eliminate flooding of inlets or manholes. When storm water is conveyed via streets, flumes, swales, or open channels, consideration will be given to pedestrian and traffic convenience and safety. Special provisions may be required by the city engineer to avoid sheeting of water across arterial intersections, inundation of crosswalks or sidewalks, inundation of driving lanes, and other safety or nuisance problems. These special provisions may include additional easements or rights-of-way, structures, flumes, or pavement width.
(Ord. No. 2186, § 1, 3-24-87; Ord. No. 2890, § 1, 10-14-03)
Ask a question about Midwest City law
Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.