§ 15-22 — Location of fire hydrants
Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances § 15-22
Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/42d1be38-d913-44c1-8d01-d5b8018a7e50
Sec. 15-22. - Location of fire hydrants.
(a) The placement of all new fire hydrants shall be made only with the approval of the appropriate fire official. (b) Fire hydrants shall be located and so spaced that no hose lay from a fire apparatus exceeds five hundred (500) feet within areas containing one- and two-family detached dwellings. Such dwellings located in areas not served by city water may qualify for the following exceptions: (1) Those having installed an approved residential sprinkler system per NFPA 13D; (2) Those having installed an approved fire detection and alarm system per NFPA 72 that is continuously monitored by a central station. (c) In all areas except those containing only one- and two-family detached dwellings, fire hydrants shall be located in such a manner that no hose line will exceed four hundred (400) feet in length to reach any accessible portion of the exterior of any building and is dependent on the ability to place an apparatus in such a manner necessary to utilize said hydrant. Distance shall be measured by the lay of the hose, not by line of sight. (d) Within all other areas, including, but not limited to, mercantile, business, educational, assembly, detention and correctional, health care, storage, industrial and multifamily dwellings, the maximum spacing shall be no more than four hundred (400) feet. Buildings of noncombustible or limited combustible construction, protected by a complete automatic sprinkler system and classified by NFPA 13 as "Light or Ordinary Hazard" may be protected by fire hydrants located with a maximum spacing of five hundred (500) feet. Distance shall be measured by the lay of the hose, not by line of sight. (e) In areas of commercial development, fire hydrants shall be located in a sufficient number and manner to supply the required flow, per the adopted edition of International Fire Code requirements, for a structure and its exposures or supply adequate water for the fire sprinkler system. (f) Structures that exceed the fire department's minimum fire flow capability shall be protected throughout by an automatic fire sprinkler system. (g) A fire hydrant shall be located within fifty (50) feet of all fire department standpipe or sprinkler connections. (h) No more than one (1) fire hydrant may be located on any dead-end water main, the fire hydrant shall be installed on the end of the line. A fire hydrant located on a dead-end water main may not be positioned further than three hundred (300) feet for six-inch lines and five hundred (500) feet for eight-inch lines from a looped water supply source. However, up to two (2) additional hydrants may be added to a dead-end main if the main size is eight (8) inches from the point of connection to the looped water supply source and the arrangement is approved by the appropriate fire official. All water mains larger than eight (8) inches shall be looped. A looped water supply shall be defined as water mains that provide multiple pathways for water flow and supply redundancy.
(Ord. No. 2884, § 1, 8-26-03; Ord. No. 2928, § 1, 8-24-04; Ord. No. 3022, § 1, 6-26-07; Ord. No. 3276, § 4, 7-12-16; Ord. No. 3602, § 1, 8-26-25)
Ask a question about Midwest City law
Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.