For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2.25 — PUD, Planned Unit Development

Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances, App. A, ch. 2, § 2.25

Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/0e2aa7cb-16d5-459f-8188-b6a0b695d8c5

2.25. - PUD, Planned Unit Development

2.25.1. General Provisions. The planned unit development, herein referred to as PUD, is a special zoning district category that provides an alternate approach to conventional land use controls to produce unique, creative, progressive, or quality land developments. The PUD may be used for particular tracts or parcels of land that are under common ownership and are to be developed as one unit according to a master development plan. The PUD is subject to special review procedures within 7.3 PUD Application and Review (Page 174), and once approved by the City Council it becomes a special zoning classification for the property it represents. 2.25.2. Intent and Purpose. The intent and purpose of the planned unit development provisions are as follows: (A) Innovative land development. Encourage innovative land development while maintaining appropriate limitations on the character and intensity of use, assuring compatibility with adjoining and proximate properties, and following the guidelines of the comprehensive plan. (B) Flexibility within developments. Permit flexibility within the development to maximize the unique physical features of the particular site. (C) Efficient use of land. Encourage efficient use of land, facilitate economic arrangement of buildings and circulation systems, and encourage diversified living environments and land uses. (D) Function, design, and diversity. Achieve a continuity of function and design within the development and encourage diversified living environments and land uses. (E) Modifications to development requirements. Provide a vehicle for negotiating modifications in standard development requirements in order to both encourage innovative development and protect the health, safety and welfare of the community. 2.25.3. Planned Unit Development Authorized. A PUD may be authorized by an amendment to the official Zoning District Map after public hearings by the Planning Commission and City Council, provided it complies with the following requirements: (A) Location and uses. A PUD shall be considered a special zoning district; and it may be authorized for any use or combination of uses permitted in this Zoning Ordinance. (B) Planned unit development master plan required. (1) The basis for review and approval of a PUD application shall be the PUD master plan, which shall be adopted as a part of the ordinance of rezoning in conformance with the requirements described in these regulations. (2) The PUD master plan shall consist of two (2) following elements: a. The design statement; and b. The master development plan map. (3) The PUD master plan establishes residential densities, as well as amount, type, and general location of all land uses. (4) The PUD master plan shall serve as the basis for review and approval of all subdivision plats and building permits within the PUD. (C) Effect of planned unit development approval. (1) Approval of a zoning change to a PUD adopts the master plan prepared by the applicant and reviewed as a part of the application. a. The master plan establishes new and specific requirements for the amount and type of land use, residential densities, development regulations and location of specific elements of the development, such as open space and screening. (2) The PUD classification replaces any previous zoning district classification of a parcel. (3) All PUDs shall establish a conventional or base zoning district to identify all applicable uses and development regulations not specified within the PUD master plan. a. The conventional or base zoning district's use and development regulations standards shall be interpreted to be the most recently adopted version of the Zoning Ordinance. b. Uses and development regulations may either be adopted into or deleted from a base zoning district and said uses and development regulations shall be applicable to PUD. 2.25.4. Criteria for Planned Unit Development (PUD) Review and Approval. Because the PUD provides the opportunity for higher densities, greater design flexibility, mixed land uses, and improved marketability, the applicant should be prepared to provide amenities and services that might not be required or possible in a conventional development. Review and approval of a PUD is, therefore, a process of negotiation between the city government and the applicant to achieve the intents and purposes of these regulations and the comprehensive plan. The following factors should be specifically included as review criteria for the evaluation of a PUD application. Other factors not listed herein may also be considered in the review process in order to respond to specific design and land use proposals: (A) Design standards. (1) The proposed PUD shall be designed to provide for the unified development of the area in accordance with the spirit and purpose of the comprehensive plan and the land uses and zoning districts adjacent to it. (2) Design of the PUD may provide for modification of conventional Zoning Ordinance requirements for such elements as setback areas, densities, setbacks, and height on individual lots in accordance with the PUD master plan. (3) Density, land use, and intensity of use requirements shall be based on the PUD master plan and shall be in conformance with the comprehensive plan. (4) Building code requirements shall not be reduced in the design of a PUD. (5) The maximum number of dwelling units within a PUD shall be based on calculation of gross density. a. Gross density shall be established in the PUD master plan and shall be calculated by dividing the total land area to be developed for residential uses (exclusive of arterial streets) by the number of dwelling units. (6) Location and type of housing shall be established in a general pattern and shown on the master development plan map. (B) Minimum design and construction standards for street and alleys. Streets and alleys for PUDs shall be designed and constructed in accordance with city standards and specifications for right-of-way width and paving cross sections; provided that modifications may be requested and approved as part of the master plan if the following criteria are met: (1) Public streets and alleys. Proposed public street and alley modifications shall satisfy the following criteria: a. Street right-of-way and paving shall be adequate to provide a traffic carrying and utility installation capacity related to the design of the overall street system, the function of the individual street, and the land uses served. b. Paving cross sections shall be designed to be adequate to provide acceptable drainage inconformity with the drainage plan for the PUD; to receive loading commensurate with anticipated traffic based on the design of the overall street system; and to have a maintenance level commensurate with that of facilities constructed to regular standards. (2) Private streets and alleys. Proposed private street and alley modifications shall satisfy the criteria for public facility modifications listed above and the following: a. Private streets shall not be connected to an adjacent parcel which is not a part of the PUD in a manner that will circulate traffic into and through the private street system. b. The owner/applicant shall clearly demonstrate the existence and capabilities of a property owners association to provide the ongoing and long-term maintenance of the private street and alley facilities that will not be provided by the city. (C) General design and development guidelines. (1) Intensities. Proposed developments shall conform to the general level of intensity outlined within the comprehensive plan and should be developed in a manner and at a scale that will be compatible with adjacent developed neighborhoods. (2) Amenities. Amenities should be considered as an important justification for development and city approval of a PUD. a. Where gross or net densities are to be increased to promote economy of development, or where other methods of land use intensification are proposed, usable open space should be furnished along with provision for its permanent retention and continued maintenance. Sidewalks and pedestrian ways should be planned where it is necessary to provide for amenities and public safety. (3) Minimum land area and frontage. The minimum area and frontage for a PUD request involving office, commercial or industrial land uses should generally be at least the minimum required by the conventional zoning associated with the proposal. (4) Streets. a. Street design should be innovative and should restrict through traffic from residential areas as much as possible. b. Encouragement should be given to the design of short local streets serving limited areas, such as the residential cul-de-sac. c. Local street right-of-way widths may be reduced to thirty (30) feet. However, a ten (10) foot easement shall be provided where utilities or sidewalks are proposed. These easements may be omitted when a letter can be provided from each utility company stating that they have no present or future need for a utility easement in the area which abuts the street. d. Development of a private street system should be considered appropriate under certain conditions where there is no through traffic. However a private street system should not serve as a reason for reduction of minimum design and paving standards. e. On-street parking bays or other similar areas where vehicles must be backed into the traffic flow should not be approved on arterial or collector streets or any local street; provided, however that certain cul-de-sac or small loop street designs may be considered as appropriate. (5) Parking. If the front building line in residential areas is less than twenty (20) feet, the Planning Commission and City Council may require additional guest parking at the suggested rate of one additional space per 7.5 units. (6) Relationship to abutting uses. a. The master development plan map should show graphically the treatments that will be employed to separate the PUD from abutting properties, including commitments to landscaping, screening, earthen berms, or similar techniques. b. It is appropriate to specifically establish areas with height limitations where a transition to more intense uses is proposed or where a higher intensity development is proposed to abut a lower intensity area. (7) Mixed land use developments. Where a PUD proposes a mix of uses which would generally be incompatible with a conventional development, the PUD master plan should specifically establish appropriate guidelines to assure a harmonious development. (8) Common access. In commercial or industrial developments, the PUD master plan should establish specific standards and locations for common access driveways both within the development and abutting arterial streets. Approval of the bonus provisions in 5.3.2. Off-Street Parking Standards (Page 93) of this Ordinance for shared parking facilities should only be authorized in PUD where this access commitment is provided in the PUD master plan.

(Ord. No. 3131, § 2, 10-26-10)

Ask a question about Midwest City law

Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.