§ 4.1 — Single-Family Facility Sound Attenuation
Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances, App. B, ch. 4, § 4.1
Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/cff0361c-eacb-4760-95a2-f61d8ba23277
4.1. - Single-Family Facility Sound Attenuation
The following sound attenuation standards apply to all new single-family detached residential uses permitted after November 25, 2010 and located within a Day-Night Average Sound Level (DNL) - Noise Contour as defined on the Airport Zoning Map (Page 35). 4.1.1. Decibel (db) DNL Zones. The Airport Zoning Ordinance shall have the following Day-Night Average Sound Level (DNL) - Noise Contours Zones: (A) 80 dB DNL Zone. This zone shall be the area shown within the 80 db DNL depicted on the Airport Zoning Map. (B) 75-80 dB DNL Zone. This zone shall be the area between the 75 and 80 db DNL depicted on the Airport Zoning Map. (C) 70-75 dB DNL Zone. This zone shall be the area between the 70 and 75 db DNL depicted on the Airport Zoning Map. (D) 65-70 dB DNL Zone. This zone shall be the area between the 65 and 70 db DNL depicted on the Airport Zoning Map. 4.1.2. Sound Level Reduction (SLR) Standards. All new single-family detached residential uses permitted after November 25, 2010 shall achieve an average interior sound level of not more than 45 decibels (dB). In order to achieve an average interior sound level of not more than 45 dB within APZ, sound level reduction (SLR) standards shall be used in new construction. The U.S. Air Force has established sound reduction standards designed to provide outdoor-to-indoor SLR of 25 dB, 30 dB and 35 dB. The requirements within this subsection are in agreement with the 2008 JLUS. The overall SLR required within a given noise zone can be determined by subtracting the required level (45 dB) from the highest noise level within that contour. For example, at the 70 dB DNL, the required reduction to obtain an internal 45 dB for residential structures is calculated as 70 dB minus 45 dB equals 25 dB. 4.1.3. Single-Family Detached Uses within 75-80 dB DNL Zone or Greater Standards. All newly constructed single-family detached uses within the 75-80 dB DNL zone or any zone with a greater dB DNL rating shall adhere to the following standards: (A) Compliance. (1) Future construction shall comply with the "Guidelines for the Sound Insulation of Residences Exposed to Aircraft Operations, Wyle Research Report WR 89-7." (2) Uses shall achieve an average interior sound level of not more than 45 decibels (dB). (3) Uses shall provide proof of compliance with the aforementioned report. 4.1.4. Single-Family Detached Uses within the 70-75 dB DNL Zone Standards. Uses shall follow the following standards to achieve a SLR of not more than 30 dB within the 70-75 db DNL zones: (A) Compliance. Compliance with the following standards shall be deemed to meet the requirements of the compatible use noise zones in which an SLR 30 is specified. (B) General. (1) Brick veneer, masonry blocks, or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. (2) At the penetration of exterior walls by pipes, ducts, or conduits, the space between the wall and pipes, ducts, or conduits shall be caulked or filled with mortar. (3) Window and/or through-the-wall ventilation units shall not be used. (4) Operational vented fireplaces shall not be used. (5) All sleeping spaces shall be provided with either a sound-absorbing ceiling or a carpeted floor. (6) Through-the-wall and/or door mailboxes shall not be used. (C) Exterior Walls. (1) Exterior walls other than as described below shall have a laboratory sound transmission class rating of at least STC-44. (2) Masonry walls having a surface weight of at least forty (40) pounds per square foot do not require a furred (stud) interior wall. At least one surface of concrete block walls shall be plastered or painted with heavy bridging paint. (3) Stud walls shall be at least four (4) inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco, or brick veneer. a. Interior surface of the exterior walls shall be of gypsum board or plaster at least one (1) inch thick, installed on the studs. The gypsum board or plaster may be fastened rigidly to the studs if the exterior is brick veneer or stucco. If the exterior is siding-on-sheathing, the interior gypsum board or plaster must be fastened resiliently to the studs. b. Continuous composition board, plywood, or gypsum board sheathing shall cover the exterior side of the wall studs behind wood or metal siding. The sheathing and facing shall weigh at least four (4) pounds per square foot. c. Sheathing panels shall be butted tightly and covered on the exterior with overlapping building paper. The top and bottom edges of the sheathing shall be sealed. d. Insulation material at least two (2) inches thick shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. (D) Windows. (1) Windows other than as described in this section shall have a laboratory sound transmission class rating of at least STC-33. (2) Glass of double-glazed windows shall be at least one-eighth-inch thick. Panes of glass shall be separated by a minimum three-inch air space. (3) Double-glazed windows shall employ fixed sash or efficiently weather-stripped operable sash. The sash shall be rigid and weather-stripped with material that is compressed airtight when the window is closed so as to conform to an infiltration test not to exceed one-half (0.5) cubic foot per minute per foot of crack length in accordance with ASTM-E-283-65-T. (4) Glass of fixed-sash windows shall be sealed in an airtight manner with a non-hardening sealant, or a soft elastomer gasket or glazing tape. (5) The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one of the following Federal Specifications: TT-S-0027, TT-S-00230, or TT-S-00133. (6) The total area of glass of both windows and exterior doors in sleeping spaces shall not exceed twenty (20) percent of the floor areas. (E) Doors. (1) Doors, other than as described in this section shall have a laboratory sound transmission class rating of at least STC-33. (2) Double door construction is required for all door openings to the exterior. Openings filled with side-hinged doors shall have one solid-core wood or insulated hollow metal core door at least one and three-fourths (1¾) inches thick separated by an airspace of at least four (4) inches from another door, which can be a storm door. Both doors shall be tightly fitted and weather-stripped. (3) The glass of double-glazed sliding doors shall be separated by a minimum four (4) inch airspace. Each sliding frame shall be provided with an efficiently airtight weather stripping material as specified in subsection (D)(3) above. (4) Glass of all doors shall be at least three-sixteenth-inch thick. Glass of double sliding doors shall not be equal in thickness. (5) The perimeter of door frames shall be sealed airtight to the exterior wall construction as indicated in subsection (D)(5). (6) Glass of doors shall be set and sealed in an airtight non-hardening sealant, or a soft elastomer gasket or glazing tape. (F) Roofs. (1) Combined roof and ceiling construction other than described in this section and subsection (G) shall have a laboratory sound transmission class rating of at least STC-44. (2) With an attic or rafter space at least six (6) inches deep, and with a ceiling below, the roof shall consist of closely butted composition board, plywood, or gypsum board sheathing topped by roofing as required. (3) If the underside of the roof is exposed, or if the attic or rafter spacing is less than six (6) feet, the roof construction shall have a surface weight of at least forty (40) pounds per square foot. Rafters, joists, or other framing may not be included in the surface weight calculation. (4) Window or dome skylights shall have a laboratory sound transmission class rating of at least STC-33. (G) Ceilings. (1) Gypsum board or plaster ceilings at least one-half-inch thick shall be provided where required by subsection (F)(2) above. Ceilings shall be substantially airtight with a minimum number of penetrations. (2) Glass fiber or mineral wool insulation at least two (2) inches thick shall be provided above the ceiling between joists. (H) Floors. (1) The floor of the lowest occupied rooms shall be slab on fill, below grade or over a fully enclosed basement. All door and window openings in the fully enclosed basement shall be tightly fitted. (I) Ventilation. (1) A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air supply requirements for various uses in occupied rooms without the need to open any windows, doors, or other openings to the exterior. (2) Gravity vent openings in attics shall not exceed code minimum in number and size. The openings shall be fitted with transfer ducts at least three (3) feet in length containing internal sound absorbing duct lining. Each duct shall have a lined 90 degree bend in the duct such that there is no direct line of sight from the exterior through the duct into the attic. (3) If a fan is used for forced ventilation, the attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20 gauge steel which shall be lined with one-inch thick coated glass fiber, and shall be at least five (5) feet long with one 90 degree bend. (4) All vent ducts connecting the interior space to the outdoors excepting domestic range exhaust ducts, shall contain at least a ten-foot length of internal sound absorbing duct lining. Each duct shall be provided with a lined 90 degree bend in the duct such that there is not direct line of sight through the duct from the venting cross section to the room opening cross section. (5) Duct lining shall be coated glass fiber duct line at least one (1) inch thick. (6) Domestic range exhaust ducts connecting the interior space to the outdoors shall contain a baffle plate across the exterior termination which allows proper ventilation. The baffle plate shall be of the same material and thickness as the vent duct material. (7) Building heating units with flues or combustion air vents shall be located in a closet or room closed off from the occupied space by doors. (8) Doors between occupied space and mechanical equipment areas shall be solid core wood or 20 gauge steel hollow metal at least one and three-fourth (1¾) inches thick and shall be fully weather-stripped. 4.1.5. Single-Family Detached Uses within the 65-70 dB DNL Zone Standards. Uses shall follow the following standards to achieve a SLR of 25 dB within the 65-70 dB DNL zones: (A) Compliance. Compliance with the following standards shall be deemed to meet the requirements of the compatible use noise zones in which an SLR 25 dB is specified. (B) General. (1) Brick veneer, masonry blocks, or stucco exterior walls shall be grouted or caulked airtight. (2) At the penetration of exterior walls by pipes, ducts, or conduits, the space between the wall and pipes, ducts, or conduits shall be caulked or filled with mortar. (3) Window and/or through-the-wall ventilation units shall not be used. (4) Through-the-wall and/or door mailboxes shall not be used. (C) Exterior Walls. (1) Exterior walls other than as described in this section shall have a laboratory sound transmission class rating of at least STC-39. (2) Masonry walls having a surface weight of at least twenty-five (25) pounds per square foot do not require a furred (stud) interior wall. At least one surface of concrete block walls shall be plastered or painted with heavy bridging paint. (3) Stud walls shall be at least four (4) inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco, or brick veneer. a. Interior surface of the exterior walls shall be of gypsum board or plaster at least one-half-inch thick, installed on the studs. b. Continuous composition board, plywood, or gypsum board sheathing at least one-half-inch thick shall cover the exterior side of the wall studs behind wood or metal siding. Asphalt or wood shake shingles are acceptable in lieu of siding. c. Sheathing panels shall be butted tightly and covered on the exterior with overlapping building paper. The top and bottom edges of the sheathing shall be sealed. d. Insulation material at least two (2) inches thick shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. (D) Windows. (1) Windows other than as described in this section shall have a laboratory sound transmission class rating of at least STC-28. (2) Glass shall be at least three-sixteenth-inch thick. (3) All operable windows shall be weather-stripped and airtight when closed so as to conform to an air infiltration test not to exceed one-half (0.5) cubic foot per minute per foot of crack length in accordance with ASTM E-283-65-T. (4) Glass of fixed-sash windows shall be sealed in an airtight manner with a non-hardening sealant, or a soft elastomer gasket or glazing tape. (5) The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one of the following Federal Specifications: TT-S-00227, TT-S-00230, or TT-S-00153. (6) The total area of glass in both windows and doors in sleeping spaces shall not exceed twenty (20) percent of the floor area. (E) Doors. (1) Doors, other than as described in this section shall have a laboratory sound transmission class rating of at least STC-28. (2) All exterior side-hinged doors shall be solid-core wood or insulated hollow metal at least one and three-fourth (1¾) inches thick and shall be fully weather-stripped. (3) Exterior sliding doors shall be weather-stripped with an efficient airtight gasket system with performance as specified in subsection (D)(3). The glass in the sliding doors shall be at least three-sixteenth-inch thick. (4) Glass in doors shall be sealed in an airtight non-hardening sealant or in soft elastomer gasket or glazing tape. (5) The perimeter of door frames shall be sealed airtight to the exterior wall construction as described in subsection (D)(5) above. (F) Roofs. (1) Combined roof and ceiling construction other than described in this subsection and subsection (g) shall have a laboratory sound transmission class rating of at least STC-39. (2) With an attic or rafter space at least six (6) inches deep, and with a ceiling below, the roof shall consist of closely butted composition board, plywood, or gypsum board sheathing topped by roofing as required. (3) If the underside of the roof is exposed, or if the attic or rafter spacing is less than six (6) inches, the roof construction shall have a surface weight of at least twenty-five (25) pounds per square foot. Rafters, joists, or other framing may not be included in the surface weight calculation. (4) Window or dome skylights shall have a laboratory sound transmission class rating of at least STC-28. (G) Ceilings. (1) Gypsum board or plaster ceilings at least one-half-inch thick shall be provided where required by subsection (F)(2) above. Ceilings shall be substantially airtight, with a minimum number of penetrations. (2) Glass fibers or mineral wool insulation at least two (2) inches thick shall be provided above the ceiling between joists. (H) Floors. (1) Openings to any crawl spaces below the floor of the lowest occupied rooms shall not exceed two (2) percent of the floor space area of the occupied rooms. (I) Ventilation. (1) A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air supply requirements for various uses in occupied rooms without the need to open any windows, doors, or other openings to the exterior. (2) Gravity vent openings in attic shall not exceed code minimum in number and size. (3) If a fan is used for forced ventilation, the attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20 gauge steel, which shall be lined with one (1) inch thick coated glass fiber, and shall be at least five (5) feet long with one 90 degree bend. (4) All vent ducts connecting the interior space to the outdoors, excepting domestic range exhaust ducts, shall contain at least a five (5) foot length of internal sound absorbing duct lining. Each duct shall be provided with a bend in the duct such that there is no direct line of sight through the duct from the venting cross section to the room opening cross section. (5) Duct lining shall be coasted glass fiber duct liner at least one (1) inch thick. (6) Domestic range exhaust ducts connecting the interior space to the outdoors shall contain a baffle plate across the exterior termination which allows proper ventilation. The baffle plate shall be of the same material and thickness as the bent duct material. (7) Fireplaces shall be provided with well-fitted dampers.
(Ord. No. 3132, § 1, 10-26-10)
Ask a question about Midwest City law
Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
