For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 43-272 — Prohibited discharge standards

Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances § 43-272

Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/cfaf580d-47cf-4f01-9b0f-9148569e9b0b

Sec. 43-272. - Prohibited discharge standards.

(a) General prohibitions. No user shall introduce any pollutant or wastewater which causes pass through or interference either directly or indirectly into the POTW. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. (b) Specific prohibitions. No user shall introduce or cause to be introduced directly or indirectly into the POTW the following pollutants, substances, or wastewater: (1) Pollutants which create a fire or explosive hazard in the POTW, including, but not limited to, wastestreams with a closed-cup flashpoint of less than one hundred forty (140) degrees F (sixty (60) degrees C) using the test methods specified in 40 CFR 261.21; (2) Wastewater having a pH less than 6.0 or more than 9.0, or otherwise causing corrosive structural damage to the POTW or equipment. (Any pH above 12.5 is considered hazardous under 40 CFR 261.22.); (3) Solid or viscous substances in amounts which will cause obstruction of the flow in the POTW resulting in interference but in no case solids greater than one-half inch(es) in any dimension; (4) Pollutants, including oxygen-demanding pollutants (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, that will cause interference with the POTW; (5) Wastewater having a temperature greater than one hundred four (104) degrees F (forty (40) degrees C), or which will inhibit biological activity in the treatment plant resulting in interference, but in no case wastewater which causes the temperature at the introduction into the treatment plant to exceed one hundred four (104) degrees F (forty (40) degrees C); (6) Petroleum oil, non-biodegradable cutting oil, or products of mineral oil origin, in amounts that will cause interference or pass through; (7) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; (8) Trucked or hauled pollutants, except recreational vehicles carrying domestic wastewater; (9) Noxious or malodorous liquids, gases, solids, or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; (10) Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts color to the treatment plant's effluent, thereby violating the city's OPDES permit; (11) Wastewater containing any radioactive wastes or isotopes except in compliance with applicable state or federal regulations; (12) Stormwater, surface water, groundwater, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, noncontact cooling water, and unpolluted wastewater, unless specifically authorized by the environmental services director; (13) Sludges, screenings, or other residues from the pretreatment of industrial wastes; (14) Medical wastes, except as specifically authorized by the environmental services director in wastewater discharge permit; (15) Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail a toxicity test; (16) Detergents, surface-active agents, or other substances which may cause excessive foaming in the POTW; (17) Fats, oils, or greases of animal or vegetable origin in concentrations greater than one hundred (100) mg/l; (18) Wastewater causing two (2) readings on an explosion hazard meter at the point of discharge into the POTW, or at any point in the POTW, of more than five (5) percent or any single reading over ten (10) percent of the lower explosive limit (LEL) of the meter. (c) Pollutants, substances, or wastewater prohibited by this section shall not be processed, nor stored in such a manner that they could be discharged to the POTW. All floor drains located in process or material storage areas where prohibited wastes are present must be discharged to the nondomestic user's pretreatment facility before connection with the POTW or be contained for collection and disposal by means other than discharge to the POTW.

(Ord. No. 3185, 12-11-12)

Ask a question about Midwest City law

Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.