§ 16-13 — Closed storm sewers
Oklahoma City Municipal Code (Supp. No. 5, Update 1: codified through Ordinance No. 28070, adopted April 21, 2026) · Oklahoma City Municipal Code § 16-13
Corpus is an independent public-information project, not the official City of Oklahoma City website. Stable reference: corpuslaw.us/code/4a510ac9-123d-47fa-b472-73e800afde42
§ 16-13. - Closed storm sewers.
(a) Closed stormwater facilities and systems must be constructed of precast or prefabricated pipe or cast-in-place or precast, closed box culvert design in conformance with DCM, and construction specifications and requirements. Stormwater facilities and systems carrying runoff from streets must be designed to accept the run-off from a 25-year frequency rain event for the drainage area involved. Provided that in sump areas the stormwater facilities and systems must be designed to convey the runoff from 50-year frequency storm event with an overflow structure provided in accordance with the DCM. (b) Stormwater facilities and systems shall provide an HGL analysis as set forth in the DCM. (c) Curb opening of flume and bollard spacing shall be designed according to DCM.
(Ord. No. 27691, § 2, 9-24-24)