For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.2.50 — RS-9 Development Standards

Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 3.2.50

Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/a9f61223-2f01-468e-ad17-8be26a202de2

Section 3.2.50 - RS-9 Development Standards.

Table 3.2-3 - RS-9 Zone Development Standards Standard a. | Minimum Density 1 | 6 units per acre b. | Maximum Density 1, 2 1. Single detached 2. Townhouse | 12 units per acre 25 units per acre 1 City Staff will calculate Minimum and Maximum Density in relation to land divisions and specific development proposals, consistent with the definition of "Density Calculation" in Chapter 1.6. 2 Duplex, Triplex, Fourplex, and Cottage Cluster development are exempt from the Maximum Density standard. c. | Minimum Lot Area 3, 4 Exceptions: 1. Townhouse 2. Triplex 3. Fourplex 4. Cottage Cluster | 3,630 sq. ft. 1,500 sq. ft. 5,000 sq. ft. 7,000 sq. ft. 7,000 sq. ft. 3 Minimum Lot Area for Flag Parcels is determined using method in Section 2.4.90.04.b.1. 4 See also Section 1.4.50.06 d. | Minimum Lot Width Exceptions: Lot with alley access only Townhouse | 50 ft. 40 ft. 20 ft. e. | Setbacks 5, 6 1. Front yard 7 2. Rear yard 3. Side yard Exceptions: Townhouse - End Unit Townhouse - Interior Unit 4. Exterior Side Yard and Rear Yard abutting a street See also "l" below. | 10 feet minimum; 25 feet maximum 5 feet minimum 5 feet minimum 0 feet one side; 5 feet opposite side 0 feet both sides 10 feet minimum Cottage Cluster development standards are modified by Section 4.10.55 - Standards for Cottage Clusters 5 See Section 4.9.50.02 - General Exceptions to Minimum Setback Standards 6 increase minimum setback to comply with Vision Clearance - see Section 4.1.30.c. 7 Determination of the location of the front yard and front lot line on Flag Parcels and Lots/Parcels with Alley-only Access will be made using the provisions in Sections 4.9.50.03 and 4.9.50.04. f. | Minimum Garage/Carport Setbacks 1. Garage/carport entrance facing/parallel to the street 2. Garage/carport entrance sideways/perpendicular to street | 19 ft. minimum 10 ft. minimum Setbacks from alleys in accordance with Section 4.0.60.j of Chapter 4.0 - Improvements Required with Development. Garages/carports are also subject to the provisions in Chapter 4.10 - Pedestrian Oriented Design Standards. g. | Minimum Setbacks and Buffering from Actively Farmed Open Space-Agricultural (OS-AG) Land See also "l" below | When residential development is proposed abutting Actively Farmed OS-AG Land, a minimum 50 ft.-wide continuous plant or plant/berm buffer is required. It is the applicant's responsibility to provide this buffer. The minimum setback for lands adjacent to Actively Farmed OS-AG Land is 100 ft. Any intervening right-of-way may be included in the 100-ft. setback measurement. Structures that existed on December 31, 2006, and that would fall within the 100-ft setback from Actively Farmed OS-AG Land are not considered non-conforming structures and no additional buffering is required to maintain the existing development. Cottage Cluster development is not subject to these provisions. See Section 4.10.55 - Standards for Cottage Clusters h. | Maximum Structure Height Exceptions: Architectural projections attached to a structure and not used for human occupancy, such as chimneys, spires, domes, elevator shaft housings, and towers Cottage Cluster development Flagpoles | 30 ft., not to exceed a solar envelope approved under Chapter 2.18 - Solar Access Permits or Chapter 4.6 - Solar Access. 40 ft. Subject to maximum structure height provisions of Section 4.10.55 - Standards for Cottage Clusters Subject to maximum structure height provisions of Section 4.7.70.b of this Code. i. | Maximum Lot Coverage | 70 percent of lot area maximum; Townhouses and Cottage Cluster development are exempt from this provision. j. | Mix of Residential Building Types | See Section 4.9.80 - Residential Building Type Variety Requirements. k. | Off-street Parking | See Chapter 4.1 - Parking, Loading, and Access Requirements. l. | Service Facilities, Mechanical Equipment, and Outdoor Storage Areas | See Section 4.2.50.01 m. | Pedestrian Oriented Design Standards | See Chapter 4.10. n. | Minimum Assured Development Area (MADA) | See Chapter 4.11 - Minimum Assured Development Area (MADA). o. | Special Flood Hazard Areas | See Chapter 2.11 - Floodplain Development Permit and Chapter 4.5 - Floodplain Provisions. p. | Significant Vegetation | See Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting and Chapter 4.12 - Significant Vegetation Protection Provisions. q. | Riparian Corridors & Locally Protected Wetlands | See Chapter 4.13 - Riparian Corridor and Wetland Provisions. r. | Landscaping | See Section 3.2.70, below, and Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting. s. | Required Green Area | See Section 3.2.70, below. t. | Landslide Hazards and Hillsides | See Chapter 4.14 - Landslide Hazard and Hillside Development Provisions.

(Ord. No. 2023-19, § 9(Exh. B), eff. 6-30-2023; Ord. No. 2025-03, § 9(Exh. B), 3-27-2025)

Ask a question about Corvallis law

Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.