§ 3.27.60 — Design Standards
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 3.27.60
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/c2d7fc7b-376a-4add-9b4e-bf9fdb2a3cf2
Section 3.27.60 - Design Standards.
3.27.60.01 Coordinated Development. New development shall be designed in a manner not to preclude development of adjacent property(ies) and to ensure the logical and efficient extension of public facilities and services, including but not limited to sanitary sewer, water, storm drainage, street, and pedestrian facility connections. 3.27.60.02 Building Orientation and Maximum Setbacks. a. All new buildings in the MUE Zone shall be oriented to existing or proposed public streets or to private streets as approved by the City as follows: 1. At least one public entrance must face each street that the building abuts. Corner entrances may be used to provide entrance orientation to two streets, provided that the length of the building adjacent to each street does not exceed 50 ft. 2. Building setbacks from streets or plazas must not exceed 20 ft., except where necessary to preserve healthy, mature tree(s). Where a lot or parcel fronts on three or more streets, this requirement applies to only two of these streets. 3.27.60.03 Weather Protection. a. Where new industrial development is constructed adjacent to street sidewalks or pedestrian plazas, a six-ft.-wide, weather-protected area, such as awnings or canopies, shall be provided over the primary entrance. b. Where new commercial or residential development is constructed adjacent to street sidewalks or pedestrian plazas, a six ft.-wide, weather-protected area, such as awnings or canopies, shall be provided along the portion of building(s) adjacent to the sidewalks and/or plazas. c. For existing development, weather protection as identified in "a," and "b," above, shall be provided when alterations, repairs, or additions to existing structures are made. However, an exception to meeting this weather-protection standard may be requested where the applicant can demonstrate, to the satisfaction of the Director, that the cost of improvements to the existing structure is less than four times the cost of providing an awning. In addition, where existing weather protection is at least four ft. in width, an exception to this standard may be authorized. 3.27.60.04 Pedestrian Amenities. a. Required Number of Pedestrian Amenities - All new structures and substantial improvements in the MUE Zone, with the exception of existing residential dwellings, shall provide pedestrian amenities. The number of pedestrian amenities provided shall comply with the sliding scale in Table 3.27-3 - Number of Required Pedestrian Amenities. Table 3.27-3 - Number of Required Pedestrian Amenities Size of Structure or Substantial Improvement | Number of Amenities < 25,000 sq. ft. | 1 25,000—50,000 sq. ft. | 2 > 50,000 sq. ft. | 3 b. Acceptable Pedestrian Amenities - Acceptable Pedestrian Amenities include: 1. Sidewalks with ornamental treatments, such as brick pavers, or sidewalks that are 50 percent wider than required by this Code. 2. Benches and public outdoor seating. 3. Sidewalk planters. 4. Public art, such as a sculpture, fountain, clock, mural, etc., with a value equal to or greater than one percent of the construction value of the structure(s). 5. Pocket parks - minimum usable area of 300 sq. ft. 6. Plazas - minimum usable area of 300 sq. ft. 7. Street trees of a caliper 50 percent wider than required by this Code - may include preservation of healthy, mature trees adjacent to the street sidewalk. 8. Other improvements approved through Chapter 2.12 - Development Standards Adjustment or Chapter 2.5 - Planned Development. 9. Additional weather protection in excess of the requirements of Section 3.27.60.03. c. Pedestrian Amenities Standards - Pedestrian amenities shall comply with the following standards: 1. Amenities must be visible and accessible to the general public from an improved street. Access to pocket parks, plazas, and sidewalks must be provided via a public right-of-way or a public access easement. 2. When provided at or near a bus stop, amenities must conform to standards of the Corvallis Transit System. 3.27.60.05 Building Design Standards. New structures and substantial improvements must provide architectural relief and interest, with emphasis at building entrances and along sidewalks, by complying with the following minimum requirements: a. Ground-floor windows must be provided for Civic and Commercial Use Types. The main front elevation(s) of buildings shall provide at least 60 percent windows or transparency at the pedestrian level. On corner lots, this provision applies to both street-facing elevations. The transparency is measured in linear fashion, such that a 100-ft.-wide building facade shall have a total of at least 60 linear ft. of windows. b. Ground-floor windows must be provided for Industrial Use Types. The main front elevation(s) of buildings shall provide at least 30 percent windows or transparency at the pedestrian level. On corner lots, this provision applies to both street-facing elevations. The transparency is measured in linear fashion, such that a 100-ft.-wide building facade shall have a total of at least 30 linear ft. of windows. c. Ground-floor entrances must include an off-set of at least eight ft. in depth and of sufficient width to easily discern the entrance location. Examples of off-sets include recesses, extensions, or other breaks in elevation. d. To break up vast expanses of single-element building elevations, building design must include a combination of architectural elements and features such as off-sets, windows, entry treatments, wood siding, brick, stucco, synthetic stucco, such as EIFS, textured concrete block, textured concrete, etc. e. Provide differentiation between ground-level spaces and upper stories. For example, bays or balconies for upper levels and awnings, canopies, or other similar treatments for lower levels can provide differentiation. Variation in building materials, trim, paint, ornamentation, windows, or other features such as public art may also be used. 3.27.60.06 Neighborhood Compatibility - Minimum Standards Adjacent to a Residential Zone. a. Height Step-down - New building roof elevation(s) shall gradually step down so that the height of the proposed structure does not exceed the height(s) of adjacent residential structures by more than one story. This provision applies to the closest 20 ft. of the structure(s) in the MUE Zone. b. Compatible Architectural Characteristics - New development adjacent to residential zones shall incorporate architectural characteristics compatible with residential development. Each new structure shall contain at least two of the following elements: 1. Roofs with a minimum 4:12 pitch; 2. Flat roofs with a cornice, or other decorative treatment; 3. Horizontal wood lap siding, brick, stone, or other material consistent with residential character; 4. Vertical breaks in roof elevation; and/or 5. Additional off-sets in building elevation c. Exterior lighting must be consistent with the lighting provisions in Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting.
(Ord. No. 2025-03, § 20(Exh. B), eff. 3-27-2025)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.