For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.6.50 — MUR Zone Development Standards

Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 3.6.50

Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/ec0fb35c-bc3a-4980-8590-d1e931d6dfb2

Section 3.6.50 - MUR Zone Development Standards

3.6.50.01 Minimum/Maximum Residential Densities. a. Minimum residential densities for strictly residential development within an MUR Zone must be 20 units per acre. b. Minimum residential densities for developments that include mixed uses within an MUR Zone must be 12 units per acre. For these mixed use developments, if less than 20 units per acre are provided, the development must include a minimum of 10 percent of the total gross floor area in nonresidential uses. c. Maximum Density - none. 3.6.50.02 Nonresidential Uses. a. Nonresidential uses in the MUR Zone must not exceed a size of 3,000 sq. ft. of gross floor area per Tenant Space and, cumulatively, must be limited to a maximum of 20 percent of the total gross floor area in the development site. b. Nonresidential uses must be developed as part of a Mixed Use Building Type (with the exception of Civic Uses) and must be developed to maintain a minimum density of 12 dwelling units per acre. When a development site is composed of two or more phases, each phase must also meet this standard. 3.6.50.03 MUR Development Standards. Table 3.6-3 - MUR Zone Development Standards Standard a. Minimum Lot Area | None b. Minimum Lot Width | None c. Setbacks 1, 2 1. Front 3 | No minimum 15 ft. maximum; interior buildings within a development are exempt from this requirement; additions to existing buildings are exempt from this requirement 2. Rear yard | 10 ft. minimum 3. Side yard | None 4. Side and rear yard adjacent to RS-6 zone | 10 ft. minimum 5. Exterior side yard | None See also "j" below. | Cottage Cluster development standards are modified by Section 4.10.55 - Standards for Cottage Clusters. 1 See Section 4.9.50.02 - General Exceptions to Minimum Setback Standards 2 Increase minimum setback to comply with Vision Clearance - see Section 4.1.30.c 3 Determination of the location of the front yard and front lot line on Flag Parcels and Lots/Parcels with Alley-only Access will be made using the provisions in Sections 4.9.50.03 and 4.9.50.04. d. Minimum Garage/Carport Setbacks 1. Garage/carport entrance facing/parallel to the street 2. Garage/carport entrance sideways/perpendicular to street | 19 ft. minimum 10 ft. minimum Setbacks from alleys in accordance with Section 4.0.60.j of Chapter 4.0 - Improvements Required with Development. Garages/carports are also subject to the provisions in Chapter 4.10 - Pedestrian Oriented Design Standards. e. Minimum Setbacks and Buffering from Actively Farmed Open Space-Agricultural (OS-AG) Land See also "j" below. | When residential development is proposed abutting Actively Farmed OS-AG Land, a minimum 50 ft.-wide continuous plant or plant/berm buffer is required. It is the applicant's responsibility to provide this buffer. The minimum setback for lands adjacent to Actively Farmed OS-AG Land is 100 ft. Any intervening right-of-way may be included in the 100-ft. setback measurement. Structures that existed on December 31, 2006, and that would fall within the 100-ft setback from Actively Farmed OS-AG Land must not be considered as non-conforming structures and no additional buffering is required to maintain the existing development. Cottage Cluster development is exempt from this provision, see Section 4.10.550 - Standards for Cottage Clusters. f. 1. Maximum Structure Height 2. Maximum Structure Height adjacent to RS-6 and RS-9 Zones Exceptions: Architectural projections attached to a structure and not used for human occupancy, such as chimneys, spires, domes, elevator shaft housings, and towers Cottage Cluster development Flagpoles | 65 ft. See Section 3.6.50.04 below. 75 ft. Subject to maximum structure height provisions of Section 4.10.55 - Standards for Cottage Clusters Subject to maximum structure height provisions of Section 4.7.70.b of this Code. g. Maximum Lot Coverage | 80 percent of the lot area maximum; Townhouses and Cottage Cluster development are exempt from this provision. h. Mix of Residential Building Types | See Section 4.9.80 - Residential Building Type Variety Requirements i. Off-street Parking | See Chapter 4.1 - Parking, Loading, and Access Requirements. j. Service Facilities, Mechanical Equipment, and Outdoor Storage Areas | See Section 4.2.50.01 k. Pedestrian Oriented Design Standards | See Chapter 4.10. l. Minimum Assured Development Area (MADA) | See Chapter 4.11 - Minimum Assured Development Area (MADA). m. Special Flood Hazard Areas | See Chapter 2.11 - Floodplain Development Permit and Chapter 4.5 - Floodplain Provisions. n. Significant Vegetation | See Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting and Chapter 4.12 - Significant Vegetation Protection Provisions. o. Riparian Corridors & Locally Protected Wetlands | See Chapter 4.13 - Riparian Corridor and Wetland Provisions. p. Landscaping | See Section 3.6.70, below, and Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting. q. Required Green Area, Private Outdoor Space, and Common Outdoor Space | See Section 3.6.70, below. r. Landslide Hazards and Hillsides | See Chapter 4.14 - Landslide Hazard and Hillside Development Provisions. 3.6.50.04 Structure Height and Building Mass. a. Where a property in the MUR Zone abuts a property in the RS-9 Zone, the height of structures in the MUR Zone is limited to a maximum of 35 ft. within a distance of 20 ft. from the Medium Density Residential property. Where a street separates the land zoned MUR from the land zoned RS-9, this height restriction must be in accordance with "d" below. See Figure 3.6-1 - Required Height Transition Area When a Development is Zoned MUR and is Next to Land Zoned RS-9. [image omitted; see the official code] Figure 3.6-1 - Required Height Transition Area When a Development is Zoned MUR and is Next to Land Zoned RS-9 b. Where a property in the MUR Zone abuts a property in the RS-6 Zone, the height of structures in the MUR Zone is limited to a maximum of 35 ft. or two stories in height within the first 50 ft.; and a maximum of 45 ft. in height within a distance of 50 - 100 ft. from the Low Density Residential property. Where a street separates the land zoned MUR from the land zoned RS-6, this height restriction must be in accordance with "d" below. See Figure 3.6-2 - Required Height Transition Area When a Development is Zoned MUR and is Next to Land Zoned RS-6. [image omitted; see the official code] Figure 3.6-2 - Required Height Transition Area When a Development is Zoned MUR and is Next to Land Zoned RS-6 c. Where the MUR Zone is separated from the Low or Medium Density Residential zone by an existing or planned street, the measurements outlined in "b," and "c," above, must be taken from the MUR side of the street, and the street must not be counted to satisfy the distance needed for the step-down in height. In cases where the MUR zoning boundary immediately abuts the Low or Medium Density Residential zoning boundary, and an existing or planned street is located within the MUR Zone and also abutting the Low or Medium Density Residential zoning boundary, the street must not be counted to satisfy the distance needed for the step-down in height. See Figure 3.6-1 - Required Height Transition Area When a Development is Zoned MUR and is Next to Land Zoned RS-9 and Figure 3.6-2 - Required Height Transition Area When a Development is Zoned MUR and is Next to Land Zoned RS-6. d. Where a property in the MUR Zone abuts a property in the RS-6 Zone, buildings on the perimeter of the MUR site and closest to the Low Density Residential zone must be limited to 150 ft. in length. e. Exceptions: Cottage Cluster development is subject to the maximum structure height provisions of Section 4.10.55 - Standards for Cottage Clusters Architectural projections attached to a structure and not used for human occupancy, such as chimneys, spires, domes, elevator shaft housings, and towers must not exceed a height of 75 feet. Flagpoles are subject to the maximum structure height provisions of Section 4.7.70.b of this Code.

(Ord. No. 2023-19, § 13(Exh. B), eff. 6-30-2023; Ord. No. 2025-03, § 13(Exh. B), 3-27-2025)

Ask a question about Corvallis law

Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.