§ 4.14.70 — Hillside Development Standards
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 4.14.70
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/bb77afd0-aaea-4f58-a7f7-9e4edf5bc5e1
Section 4.14.70 - Hillside Development Standards.
4.14.70.01 Purposes. Hillside Development standards have been developed for the following purposes: a. To plan development to fit the topography, soil, geology, and hydrology of hillsides; b. To align the built surface infrastructure, such as streets and waterways, with the natural contours of terrain; and to minimize cutting and filling in developments; c. To minimize soil disturbances and the removal of native vegetation, and to avoid these activities during winter months, unless impacts can be mitigated; d. To encourage the design of developments and the utilization of construction techniques that minimize erosion and surface water runoff; e. To balance a view of the hills with the view from the hills; f. To provide or maintain landscaping that enhances the identified open space resources; and g. To design developments that consider landscaping management that will minimize the threat of fire on improved property and the spreading of fire to wildland habitat. 4.14.70.02 Applicability. Areas with slopes of 10 percent or greater are identified on the Natural Hazards Map. The following standards regulate development on areas with slopes of 10 percent or greater. In addition to these regulations, the Standards for Development in Steeply Sloped Areas in Section 4.14.50 apply to development in areas with slopes of 15 percent or greater. The Natural Hazards Map provides information regarding the location of slopes of 10 percent or greater on property within the Corvallis Urban Growth Boundary. 4.14.70.03 Definitions. a. Natural Hazards Map - The Natural Hazards Map is based on recent aerial photography (2002) and provides a level of accuracy equivalent to two-feet contour intervals. An applicant for development may contest the accuracy of the slope data on the Natural Hazards Map by providing a slope survey prepared and stamped by a licensed surveyor. The slope survey must show Natural Grade, prior to any site grading. b. Individual Lot Grading - Grading done on an individual lot, in conjunction with the development of a building, or buildings, on the lot. c. Mass Grading - Site grading done in anticipation of future development, prior to grading done to accommodate specific structures. Typically, grading for street and infrastructure improvements is done in conjunction with Mass Grading. For Subdivisions, Mass Grading is done after preliminary plat approval, but prior to application for Building Permits for individual lots. d. Eight-feet Standard - Restricts grade changes (cuts or fills) in excess of eight feet on an individual lot or development site. Cut and fill is measured vertically from Natural Grade. In no case shall a combination of cut and fill in the same location exceed 16 feet e. 10-feet Standard - Restricts grade changes (cuts or fills) in excess of 10 feet in an area where an exception to the Eight-feet Standard is allowed. Cut and fill is measured vertically from Natural Grade. In no case shall a combination of cut and fill in the same location exceed 16 feet f. 12-feet Standard - Restricts grade changes (cuts or fills) in excess of 12 feet in an area where an exception to the Eight-feet Standard is allowed. Cut and fill is measured vertically from Natural Grade. In no case shall a combination of cut and fill in the same location exceed 16 feet 4.14.70.04 Grading Regulations. a. Types of Grading - The following regulations address two types of grading, both of which are defined in Section 4.14.70.03, above: 1. Mass Grading; and 2. Grading on Individual Lots. b. These regulations prescribe grading area limitations based on zoning and lot size, as set out in Sections 4.14.70.04.c.3 and 4.14.70.04.d.2 - 1. On development sites where both Mass Grading and Individual Lot Grading are employed, Mass Grading and Individual Lot Grading must be contained within the same grading limitation areas. The amount of gradable area allowed, per lot, is the same under both standards. This means that when Mass Grading is employed, the area that is Mass Graded on an individual lot will be the area in which Individual Lot Grading is allowed, unless the Mass Graded area is less than the maximum gradable area allowed. In this case, additional area, up to the maximum allowed, can be graded at the time of Individual Lot Grading. 2. The remaining provisions of this Section in 4.14.70.04.c through 4.14.70.04.e, below, are organized as follows: a) Mass Grading Standards; b) Individual Lot Grading Standards; and c) Terracing Requirements and Design Standards. 3. Exceptions to these standards for streets may be allowed through provisions in Director's Interpretation case DDI17-00002 (Order 2017-049), the Planned Development process of Chapter 2.5 - Planned Development, or through the Capital Improvements Program process. c. Mass Grading Standards - The following standards shall apply to development throughout the City of Corvallis: 1. Maximum Allowed Cut Depth and Fill Height - The following standards govern the maximum cut depth and fill height: Site Characteristics | Maximum Cut Depth and Fill Height No Extenuating Conditions | Eight-feet Standard One Extenuating Condition | 10-feet Standard only where allowed to work around extenuating condition Two or more Extenuating Conditions | 12-feet Standard only where allowed to work around extenuating conditions 2. Extenuating Conditions - Exceptions to the Eight-feet Standard for Mass Grading shall be based on the following specific extenuating conditions: a) Street/Pedestrian Alignment - Additional Cut/Fill provides for the alignment of a necessary street or pedestrian connection. A necessary street or pedestrian connection is one which is needed to create a Block Perimeter as required in Chapter 4.0, or which is identified in an adopted City Master Plan document. A necessary street connection must comply with the slope standards in Section 4.0.60.k of Chapter 4.0 Improvements Required with Development. Section 4.0.60.k stipulates that Arterial Streets shall not exceed a six percent grade, Collector and Neighborhood Collector Streets shall not exceed 10 percent, and Local and Local Connector Streets shall not exceed 15 percent. The width and overall extent of any street exceeding the Eight-feet Standard shall be minimized, where feasible, to minimize grading impacts. b) Significant Natural Feature - Additional cut/fill is necessary to protect a Significant Natural Feature, which is defined as a feature subject to a Natural Hazards (except slopes) and/or Natural Resource Overlay on the Comprehensive Plan Map, or a Significant Tree, as defined in Chapter 1.6 - Definitions. In the case of a preserved tree, a certified arborist must find that the proposed cut/fill exception would preserve the viability of a Significant Tree that would otherwise have been damaged by the application of the Cut and Fill Standards. c) Detention Facilities - To accommodate stormwater detention facilities where no other viable location exists on the site. 3. Grading Area Limitations - The following requirements apply to Mass Grading in areas with slopes equal to or greater than 10 percent, as mapped on the Natural Hazards Map: a) Low and Medium Density Residential Development Zones - Ultimate Lot Size of Tentatively Approved Subdivision/develop-ment within Low and Medium Density Residential Development Zones | Mass Grading Regulations < or = 6,500 sq. feet | Grading up to 100 percent of the lot area is allowed. Grading shall comply with the Eight-feet Standard, unless extenuating conditions are present. > 6,500 sq. feet, but < 10,000 sq. feet | Grading up to 6,500 sq. feet of each lot is allowed. Grading shall comply with the Eight-feet Standard, unless extenuating conditions are present. > or = 10,000 sq. feet | No Mass Grading is allowed. See standards for Individual Lot Grading b) Medium-high and High Density Residential Development Zones - Medium-high and High Density Residential Development Zones | Mass Grading Regulations: RS-12, RMU-12, RS-20, RMU-20, and MUR Zones | For development sites greater than 6,500 sq. feet in size - Graded area shall not exceed 75 percent. The Eight-feet Standard shall apply, unless extenuating conditions are present. For development sites less than or equal to 6,500 square feet in size - Grading of up to 100 percent of the site is allowed. The Eight-feet Standard shall apply, unless extenuating conditions are present. c) Nonresidential Development Zones - Nonresidential Zones | Grading Regulations All Commercial and Industrial Development Zones, OSU Zone, C-OS, and AG-OS Zone | For development sites greater than 6,500 square feet in size - Graded area shall not exceed 75 percent. The Eight-feet Standard shall apply, unless extenuating conditions are present. For development sites less than or equal to 6,500 square feet in size - Grading of up to 100 percent of the site is allowed. The Eight-feet Standard shall apply, unless extenuating conditions are present. d. Individual Lot Grading Standards - These standards are in addition to Section 4.14.70.04.c, above, and apply to lots which contain slopes equal to or greater than 10 percent, as mapped on the Natural Hazards Map. 1. Maximum Allowed Cut Depth and Fill Height - The following standards govern the maximum cut depth and fill height: Extenuating Conditions | Maximum Cut and Fill Height No Extenuating Conditions | Eight-feet Standard One Extenuating Condition | 10-feet Standard only where allowed to work around extenuating condition Two Extenuating Conditions | 12-feet Standard only where allowed to work around extenuating conditions If lot would otherwise be unbuildable | The least extensive cut and fill necessary, not to exceed the 12-feet Standard, to reach the Minimum Assured Development Area, as defined by Chapter 4.11 - Minimum Assured Development Area (MADA). a) Extenuating Conditions - Exceptions to the Eight-feet Standard for Individual Lot Grading shall be based on the following specific extenuating conditions: 1) Street/Pedestrian Alignment - Additional Cut/Fill provides for the alignment of a necessary street or pedestrian connection. A necessary street or pedestrian connection is one which is needed to create a Block Perimeter as required in Chapter 4.0, or which is identified in an adopted City Master Plan document. 2) Significant Natural Feature: Additional cut/fill is necessary to protect a Significant Natural Feature, which is defined as a feature subject to a Natural Hazards (except slopes) and/or Natural Resource Overlay on the Comprehensive Plan Map; or a Significant Tree, as defined in Chapter 1.6 - Definitions. In the case of a preserved tree, a Certified Arborist must find that the proposed cut/fill exception would preserve the viability of a Significant Tree that would otherwise have been damaged by the application of the Cut and Fill Standards. 3) Maintain Driveway Slope - Additional Cut/Fill is necessary to allow for the construction of a driveway at a slope of 15 percent or less. It must be demonstrated, to the satisfaction of the Building Official, that other driveway alignments have been considered and are not feasible before additional Cut/Fill is authorized. b) Locational Standards - 1) Within the portion of each lot within 50 feet of the edge of public right-of-way, the combination of cuts and fills may not exceed 16 feet from Natural Grade, as measured within a linear distance perpendicular from the edge of right-of-way to the 50-feet boundary; and 2) All retaining walls must be located at least four feet from any property line or easement line. 2. Gradable Area - In no case shall the cumulative impact of Mass Grading and Individual Lot Grading impact more site area on an individual lot than is allowed under the following standards: a) Low and Medium Density Residential Development Zones - Lot size within Low and Medium Density Residential Development Zones | Grading Regulations < or = 6,500 sq. feet | Grading up to 100 percent of the lot area is allowed. Grading shall comply with the Eight-feet Standard, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. > 6,500 sq. feet, but < 10,000 sq. feet | Grading up to 6,500 sq. feet of each lot is allowed. Grading shall comply with the Eight-feet Standard, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. > or = 10,000 sq. feet | Grading area is limited to 6,500 sq. feet + 25 percent of lot area over 10,000 sq. feet Grading shall comply with the Eight-feet Standard, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. b) Medium-high and High Density Residential Development Zones - Medium-high and High Density Residential Development Zones | Grading Regulation RS-12, RMU-12, RS-20, RMU-20, and MUR Zones | For development sites greater than 6,500 square feet in size - Graded area shall not exceed 75 percent. The Eight-feet Standard shall apply, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. For development sites less than or equal to 6,500 square feet in size - Grading of up to 100 percent of the site is allowed. The Eight-feet Standard shall apply, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. c) Nonresidential Development Zones - Nonresidential Development Zones | Grading Regulations All Commercial and Industrial Development Zones, OSU Zone, C-OS, and AG-OS Zone | For development sites greater than 6,500 sq. feet in size - Graded area shall not exceed 75 percent. The Eight-feet Standard shall apply, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. For development sites less than or equal to 6,500 sq. feet in size - Grading of up to 100 percent of the site is allowed. The Eight-feet Standard shall apply, unless extenuating conditions are present. Grading must also comply with adopted Building Code standards. e. Terracing Requirements and Design Standards - When a cut or fill, or combination thereof, exceeds eight feet and is greater than a 25 percent slope, terracing shall be provided, as follows: 1. For cuts/fills between 8-10 feet, at least one terrace shall be provided between the two- and eight-feet level, with a shelf no less than six feet deep. The slope of the shelf may not exceed 20 percent. 2. For cuts/fills that are more than 10 feet, risers shall not exceed four feet in height and shelves shall be a minimum of six feet deep. The slope of the shelf may not exceed 20 percent. 3. Terraces shall be landscaped with a combination of ground cover plants and shrubs, planted with adequate coverage to stabilize soil in the terraced areas. Trees shall be required, at a minimum 30 feet on-center spacing, to mitigate trees removed due to grading and to stabilize soil in the shelf area. Irrigation and maintenance for required landscaping shall be addressed as stipulated in Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting. 4. Wall materials and landscaping shall be subject to final review and approval by the City Engineer and Community Development Director. Acceptable exterior wall materials include quarried stone, brick, concrete masonry, and similar quality materials. Additional flexibility shall be allowed for wall materials for retaining walls which are wholly internal to the development site, provided the materials and design meet Oregon Structural Specialty Code requirements. Retaining walls shall comply with all applicable Building Code requirements. 5. Exceptions to the terracing requirement may be allowed by the City Engineer and Community Development Director if the applicant demonstrates, with the submittal of a report from a certified arborist, qualified Stream scientist, or qualified wetlands scientist that potential impact to an existing Significant Tree or a Significant Natural Feature in the area of the cut and fill would be significantly reduced by an exception to the terracing requirement. A Significant Natural Feature is defined in Chapter 1.6 - Definitions. In the case of a preserved tree, a certified arborist must find that the proposed retaining wall treatment would preserve the viability of a Significant Tree that would otherwise have been damaged by the application of the Cut and Fill Standards, and that the Tree's continued growth will not adversely affect the structural integrity of the wall. 6. Per Chapter 2.12 - Development Standards Adjustment, exceptions to the requirements in "1," through "5," above, may be granted through the Development Standards Adjustment (DSA) process, if the exceptions qualify as a Minor or Major DSA. The DSA may allow an increase in retaining wall height of up to 20 percent of the permitted height, or a reduction of shelf width of up to 20 percent of the required depth, subject to compliance with all DSA criteria in Section 2.12.30.06.
(Ord. No. 2021-22, eff. 11-24-2021; Ord. No. 2022-06, eff. 3-17-2022; Ord. No. 2024-26, § 37(Exh. A), eff. 1-1-2025)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.
