§ 7.08.200 — Aerial apparatus access
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Municipal Code § 7.08.200
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/8e5a106b-89c1-41d4-ad19-1553f07558a1
Section 7.08.200 - Aerial apparatus access.
1) OFC Section D105 as adopted by this Chapter is amended to add Sections D105.1, D105.1.1, D105.4, D105.5, and D105.5.1 as follows: D105.1 Where required. Building or portions of buildings or facilities where the vertical distance between the grade plane and the highest roof surface (see D105.1.1 below) exceeds 30 feet is required to be provided with an approved fire apparatus access roads capable of accommodating fire department aerial apparatus. Overhead utility and power lines cannot be located within the aerial fire apparatus access roadway. D105.1.1 Building height definition. For the purposes of Section D105.1 building height is measured using the highest roof line/peak of the structure, measured from finished grade or ground up to the uppermost level of that roof's eave (30 feet from finish grade/ground level to the roofing surface - above the "eave with the highest roof line or peak"). Roof surface heights greater than 30' from ground/grade, will require an approved fire aerial apparatus access road. D105.2 Width. Aerial fire apparatus access roads must have a minimum unobstructed width of 26 feet, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to Building. At least one of the required access routes meeting this condition must be located within a minimum of 15 feet and a maximum of 30 feet from the building, and must be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned must be approved by the Corvallis Fire Chief. D105.4 Obstructions. Overhead utility and power lines cannot be located over aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions may be permitted to be placed with the approval of the Corvallis Fire Chief. D105.5 Modifications. For residential structures up to and including 40 feet in height as defined by Appendix D105.1.1, where fire aerial apparatus access roads are not possible, FD access and specifications are allowed to be modified by the Corvallis Fire Chief where the following condition applies: D105.5.1 Automatic fire sprinkler system. A building has been equipped with an automatic fire sprinkler system that was not prescriptively required by the 2019 OFC, OSSC, or ORSC. The system must be installed in accordance with the provisions of NFPA 13, NFPA 13R, or NFPA 13D.
(Ord. 2023-17, § 1(Exh. A), 05/15/2023; Ord. No. 2020-08, §§ 2, 3(Exh. A), Repealed and Replaced, 4/20/2020; Ord. 2014-08, § 1 and § 2, 07/21/2014)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.