For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.13.060 — Location rules and review criteria

Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Municipal Code § 8.13.060

Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/0060d809-3fe7-4955-95b0-7e99d2cd7354

Section 8.13.060 - Location rules and review criteria.

1) The Development Services Manager will review applications for compliance with the following criteria: a) Location. The siting of one or more Mobile Food Units year-round is limited to private properties located in a Commercial Mixed Use Zone (CMU-1, CMU-2 or CMU-3)and property in the OSU Zone. b) Street Setback. Mobile Food Units that orient the service window toward the public right-of-way must maintain a minimum setback of 2 feet from the public right-of-way. Service window orientation toward the public right-of-way is allowed only where a minimum 5-ft. wide sidewalk exists along the subject street frontage. For Mobile Food Units that orient the service window away from the public right-of-way, there is no minimum right-of-way setback requirement. No MFU, common seating areas or other site features may encroach into the public right-of-way or any required vision clearance area(s). c) Alley Setback. 2 ft. minimum required along all alley right-of-way. d) Interior Yard Setbacks. 6 ft. minimum. e) Separation. Mobile Food Units must maintain the following minimum separation from other features on the site: - 6 ft. between units on a property; - 6 ft. from structures including decks, patios, park/picnic benches and permanent seating areas; - 4 ft. from individual temporary seating areas comprised of non-flammable materials. f) Trash Disposal. Trash receptacles must be provided on site at a rate of one (1) receptacle for every two (2) Mobile Food Units or fraction thereof. For seating areas, an additional trash receptacle must be provided for every 16 seats or fraction thereof. All trash receptacles must be emptied and maintained, and must be located a minimum of ten (10) feet from combustible fuel tanks. Receptacles and waste handling units for refuse, recyclables, and returnables used with materials containing food residue and used outside the food establishment shall be designed and constructed to have tight-fitting lids, doors, or covers. g) Accessibility. Accessible Routes into, throughout, and adjacent to a property with one or more mobile food units shall be maintained in accordance with Chapter 11 of the Oregon Structural Specialty Code. h) Awnings. Each mobile food unit may provide awnings for shelter to customers. The awnings must be fully attached to the unit, have a minimum of seven (7) feet of vertical clearance, and be able to be closed or removed. Awnings shall not be subject to setback requirements, but in no case shall awnings extend over the adjacent sidewalk or public right-of-way. All awnings must be flame resistant per Oregon Fire Code. i) Building Permits. Any structures that require building permits are subject to such permitting and applicable sections of the Land Development Code and Chapter 11 of the Oregon Structural Specialty Code. j) Signs. Signage permanently affixed to a Mobile Food Unit is permissible and is exempt from sign standards in Land Development Code (LDC) Chapter 4.7 - Sign Regulations. Notwithstanding provisions in LDC Section 4.7.80.04, one (1) temporary sign per Mobile Food Unit is permitted to be placed on the subject site. Temporary signs may be no larger than six (6) square feet, may only be placed on private property, and must not obstruct pedestrian pathways. Notwithstanding LDC Chapter 4.7 or Municipal Code, no temporary sign advertising a vendor may be placed within public right-of-way or required vision clearance areas. Temporary signs authored under this Section may only be present on the property during the Mobile Food Unit operating hours. Permanent signs assigned to the subject property (not temporary signage) must conform to all applicable standards in LDC Chapter 4.7. k) Utilities. Mobile Food Units that are fully contained; i.e., units that provide their own water, power, and waste disposal, are permitted with no additional utility considerations beyond the permitting process and site plan approval described herein. Units that require a water source, power source, or waste disposal location are permitted only where the Development Services Manager has approved site plans that show safe access and location of the aforementioned provisions. Such provisions are subject to all applicable building permits and SDC requirements. Mobile Food Units that connect to public sanitary sewer lines must utilize a grease interceptor. l) Restrooms. Restroom facilities must be provided for each Mobile Food Unit site in accordance with the following: i) For sites containing no more than four (4) Mobile Food Units, the property owner must either: 1. Provide permanent restroom facilities on-site; 2. Provide at least two (2) portable restrooms on-site, including hand-washing stations. Portable restrooms and hand-washing stations must be regularly maintained and kept in sanitary condition for employees and patrons. Portable restrooms must also provide hot and cold running water integral or adjacent to the structure and a pumping schedule to show the unit is serviced properly. The hand-washing station must provide hot and cold or tempered water of at least 100F and may not be considered a temporary restaurant-type setup; or 3. Obtain written permission from the owner of a business or property located within 500 feet of the subject site, allowing Mobile Food Unit operators and patrons to access restroom facilities. Where off-site accessible restroom facilities are utilized, the MFU site property owner must provide information on the MFU site indicating where restroom facilities can be accessed during MFU operating hours. 500 foot minimum distance requirement will be measured based on walking distance from site perimeter. ii) For sites containing five (5)—ten (10) Mobile Food Units, off-site restroom facilities are not an allowable option. Permanent on-site restroom facilities or on-site portable restrooms and hand-washing stations must be provided in accordance with i)1. or i)2. above. iii) For sites containing more than ten (10) Mobile Food Units, permanent restroom facilities must be provided on-site. m) Driveway Surfacing. All new vehicle parking and/or maneuvering areas must be paved in accordance with City standards. Existing legally non-conforming parking and/or maneuvering surfaces (installed prior to February 7, 1980) may continue to be utilized if not in conflict with ADA requirements, but shall not be expanded. n) Improvements. For all sites containing more than ten (10) Mobile Food Units, the following additional standards apply: i) The public improvement standards of LDC Chapter 4.0 and street tree standards of LDC Chapter 4.2 must be met for the development site. ii) All Mobile Food Units on the subject site must directly connect to public sanitary sewer lines, and must utilize a grease interceptor. iii) A minimum of four (4) City-standard bicycle parking spaces must be provided on the site.

(Ord. 2025-02, § 1(Exh. A), 01/21/2025; Ord. 2023-03, § 1(Exh. A), 01/17/2023; Ord. 2013-10 § 1, 06/03/2013; Ord. 2011-15 § 1, 10/03/2011)

Ask a question about Corvallis law

Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.