For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12.50.250 — Fences, Free-Standing Walls, Hedges and Berms

Municipal Code of the City of Hillsboro, Oregon (Codified through Ordinance No. 6513, adopted March 3, 2026 (Supp. No. 2)) · Hillsboro Community Development Code subch. 12.50, § 12.50.250

Corpus is an independent public-information project, not the official City of Hillsboro website. Stable reference: corpuslaw.us/code/d8e37c05-9e54-4f53-8f4d-21be01544fbb

12.50.250 - Fences, Free-Standing Walls, Hedges and Berms.

A. Purpose. Fences, walls, hedges and berms mark property boundaries and provide privacy and security. Standards for construction and installation of fences, walls, hedges and berms are intended to ensure that these features are attractive from the public view, accomplish their intended purposes, and are reasonably maintained for both private and public benefit. B. Applicability. The standards of this section shall apply: 1. To all Type II or III development applications in which fences, hedges, free-standing walls or berms are proposed or required as a condition of approval; and 2. To any fences, hedges, free-standing walls or berms installed outside the land use approval process. C. Fence Permit Required; Exception. 1. Except as provided in paragraph 2 below, installation of a new fence or wall, or relocation of a portion of an existing fence or wall, shall require submittal and approval of a fence permit application according to the process specified in Section 12.80.060. 2. When required through a Type II or Type III land use approval, a separate fence permit is not required for installation of a fence, free-standing wall, hedge or berm consistent with that approval. D. Residential Fence and Wall Standards. These standards in this subsection apply to all residential fences and walls. 1. Fences and walls in residential zones are limited to 6 feet 2 inches in height except when: a. A residential zone abuts a Commercial, Mixed-Use, Urban Center, Institutional or Industrial zone, fences may be up to 8 feet 2 inches in height. b. On interior lots, fences and walls within a front yard setback shall not exceed 4 feet 2 inches. c. On corner lots, through lots and multiple frontage lots, the 4-foot 2-inch height limitation applies only at the front yard setback abutting the façade with the front door. d. On flag lots, the height limit of 4 feet 2 inches does not apply in the front yard setback. 2. Soundwalls installed adjacent to light rail facilities are exempt from these height restrictions above. 3. Fences and walls in residential zones shall not conflict with vision clearance requirements in Section 12.50.260. 4. One arbor, gate, or similar garden structure not exceeding 8 feet in height and 4 feet in width is allowed within the front yard outside a vision clearance triangle. 5. Use of barbed wire, razor wire, and electric fences shall be consistent with the requirements of the Hillsboro Municipal Code. 6. Chain link fences shall include a top rail for security and maintenance. Chain link fences installed adjacent to landscaped areas, wetlands, or open space areas shall have a black, dark brown, or dark green powder coating. E. Fencing and Wall Requirements for New Residential Developments. In addition to the standards in subsection D, above, the following standards apply to all applications for Development Review, preliminary Subdivision plat or Planned Unit Development concept plan approval for new residential development. 1. Applications for Development Review, preliminary Subdivision plat or Planned Unit Development concept plan approval for new residential development shall submit proposed fencing or wall plans in compliance with the standards in Table 12.50.250-1. 2. Perimeter street fences and walls shall be installed by the developer prior to the acceptance of public infrastructure, according to the standards listed in Table 12.50.250-1. 3. Uniform interior yard fences and walls shall be constructed during or after home construction, according to the fencing plan approved during preliminary review. Table 12.50.250-1: Perimeter Fence and Wall Standards for New Residential Developments Project Character | Preferred Standard Arterial or collector frontage where garages and front doors face the interior street and rear yards face the arterial or collector street | • 1st: Masonry or brick walls; anti-graffiti sealant • 2nd: Solid wood fence; masonry or brick columns with cap board; anti-graffiti sealant • All fences to be maximum 6 feet high except in vision clearance areas • Construction to include a minimum 3-foot wide landscaped strip between the sidewalk and the fence or wall Arterial or collector frontage where front doors face the arterial or collector street and garages face the interior street | • 1st: Masonry or brick walls • 2nd: Metal fence with masonry or brick columns • 3rd: Solid wood fence with cap board • All fences to be maximum 4 feet high except in vision clearance areas • Individual gates or openings to be provided for single detached dwellings; consolidated gates or openings may be provided for multiple dwelling structures and duplex structures Neighborhood route or local street frontage where garages and front doors face the interior street | Uniform fencing plan to be approved during Type II or Type III application review Neighborhood route or local street frontage where garages and front doors face the neighborhood route street | Uniform fencing plan, to be approved during Type II or Type III application review Perimeter fences or walls adjacent to surrounding properties (not street frontage) | Uniform fencing plan, to be approved during Type II or Type III application review F. Commercial, Industrial, and Institutional Fence and Wall Standards. 1. Fences and walls in commercial, industrial, and institutional zones shall not exceed 8 feet in height. 2. Chain link fences shall include a top rail for security and maintenance. Chain link fences installed adjacent to landscaped areas, wetlands, or open space areas shall have a black, dark brown, or dark green powder coating. 3. Use of electric fences and/or fences topped with barbed wire, razor wire, or similar installations shall comply with the requirements of the Hillsboro Municipal Code. 4. Soundwalls installed for sound attenuation are exempt from the height restrictions contained in this section. G. Standards for Hedges. In all zones, vegetation hedges may be installed in compliance with the following standards: 1. Hedge plantings shall not include nuisance plants as defined in Section 12.01.500; 2. Hedge heights may exceed the maximum fence height standards in any zone; 3. Hedges may be installed without a fence permit, but must comply with the vision clearance requirements in Section 12.50.260; and 4. Hedges shall not extend into the public right-of-way. H. Standards for Berms. As an alternative or in addition to perimeter fences or walls, projects may include perimeter earthen berms. Berms in residential developments shall be a maximum 6 feet in height, with a maximum 25% slope. Berms in commercial, industrial or institutional developments may exceed this height and/or slope if approved through the Development Review process. If approved, berms shall include stabilizing landscaping on all sloped areas; irrigation; and provision for drainage at the toe of all slopes.

(Ord. 6451 § 1, 2023; Ord. 6401 § 1, 2022; Ord. 6393 § 1, 2021; Ord. 6322 § 1, 2019; Ord. 6294 § 1, 2019; Ord. 6120 § 1, 2015)

Ask a question about Hillsboro law

Corpus searches the Hillsboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.