For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12.65.720 — Multi-Dwelling Residential Design Standards

Municipal Code of the City of Hillsboro, Oregon (Codified through Ordinance No. 6513, adopted March 3, 2026 (Supp. No. 2)) · Hillsboro Community Development Code subch. 12.65, § 12.65.720

Corpus is an independent public-information project, not the official City of Hillsboro website. Stable reference: corpuslaw.us/code/c33d7d7b-ca08-4198-8e2d-b96aaff3140f

12.65.720 - Multi-Dwelling Residential Design Standards.

A. Purpose. These standards are intended to ensure that higher density residential developments are designed to reinforce the goal of creating a complete, connected and green community, consistent with the policies in the South Hillsboro Community Plan, developments should provide high quality design that evokes a sense of place and permanence and a strong connection with the street. B. Applicability. 1. The design standards in this section apply to all multi-dwelling developments in the South Hillsboro Plan District unless alternative standards are requested by the applicant and approved by the review authority. 2. Developments on Active Use streets are also subject to the design standards in Section 12.65.850 and the more restrictive standards apply. 3. Applicants may request adjustments to these standards pursuant to Section 12.80.154 or 12.80.156. C. Exceptions. 1. Non-conforming situations which exist prior to the adoption and effective date of the South Hillsboro Plan District. 2. If alternative standards have been approved through a discretionary process. D. Standards. 1. Main entries shall be prominent and defined, as demonstrated by compliance with the standards of Subsections 12.50.710.C.1. and 12.50.720.C.1 within all zones in the South Hillsboro Plan District. 2. On sites with multiple street frontages, the developer shall designate and orient the front of the structure to the street with the highest classification. Where streets are of equal classification, the developer may choose which street frontage to designate for the purposes of this standard. Developments on Active Use streets are subject to the Maximum Setback and Front Property Line Coverage requirements in Section 12.65.850. 3. Windows. a. Front Elevation. i. At least 25% of the area of each façade facing a street or commonly-accessible open space shall be windows or entry doors with window insets, as illustrated in Figure 12.65.720-A. On multistory structures a minimum of 20% of the ground floor facing a street or commonly-accessible open space shall be windows or entry doors with window insets. b. Side Elevation. At least 15% of the area of each side façade shall be windows or doors with window insets. c. Rear Elevation. i. At least 20% of the area of each rear elevation shall be windows or doors with window insets. ii. At least 10% of the area of each side or rear elevation shall be windows or doors with window insets where a garage is present. d. "Percent of elevation" is measured as the percentage of the façade area, excluding gable ends which are not part of an upper story, containing doors, porches, balconies, terraces and/or windows per Figure 12.65.720-A. The standard applies to each full and partial building story. Figure 12.65.720-A: Three or More Unit Townhouse and Multi-Dwelling Window Calculation [image omitted; see the official code] 4. Roofs. The standards of Section 12.50.720 shall apply. 5. Foundation Materials. The standards of Section 12.50.710 shall apply. 6. Articulation. In addition to the standards of Section 12.50.710, street-facing elevations (walls and roofs) shall be divided into smaller areas or planes to break up large expanses of uninterrupted building surfaces. Street-facing elevations with areas larger than 750 square feet shall be divided into distinct planes of 500 square feet or less. In implementing this standard, areas of wall or roof entirely separated from other wall areas by a projection, such as the porch or a roof over a porch, shall be considered individual building wall planes. 7. Detailed Design Elements. In addition to the design elements required in Section 12.50.710, public alley access is required for townhouse developments unless it is determined by the Review Authority to be infeasible due to natural resource, public infrastructure or topography constraints. For multi-dwelling development with individual garages, or where townhouses cannot be alley loaded, street access may be allowed provided each dwelling meets the following standards: a. The length of the garage wall or parking area facing the street shall not exceed 40% of the length of the street-facing building façade. b. The garage wall that faces a street shall be no closer to the street lot line than the longest street-facing wall of the dwelling unit. Figure 12.65.720-B: Detailed Design Elements [image omitted; see the official code] 8. Exterior Finish Materials. The following finish materials are prohibited or limited by the standards below: a. Plain concrete block, plain concrete, corrugated metal, plywood and sheet pressboard are not allowed as exterior finish materials. b. Composite and/or cementitious horizontal boards manufactured from wood or other products, such as hardboard or hardplank, may be used when the board product is less than 8 inches wide. c. Where horizontal siding is used, it must be shiplap or clapboard siding composed of boards with a reveal of 3 to 6 inches. d. Trim must mark all building rooflines, entries, windows, and doors on all façades. Roofline (fascia) and porch trim shall be at least 6 inches wide and 1 inch thick. Window and door trim shall be at least 3 inches wide and ⅝ inch thick. 9. Waste and Recycling Facilities. The standards of Section 12.50.270 shall apply.

(Ord. 6401 § 1, 2022; Ord. 6322 § 1, 2019; Ord. 6110 § 8, 2015)

Ask a question about Hillsboro law

Corpus searches the Hillsboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.