§ 28.06.055 — Life Safety

Portland City Code (non-zoning titles; Title 33 separately); partial · Portland City Code § 28.06.055

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/61eb50b1-9066-4ce3-b967-134392122b07

28.06.055 Life Safety.

(Added by Ordinance 181437; amended by Ordinances 191154 and 192002, effective January 10, 2025.)

A.  One- and two-family floating homes.  Floating homes, tender houses, combo-structures and boathouses must be constructed and maintained in compliance with the requirements of the relevant Specialty Codes and of Titles 24, 28, and 29 of this Code.

1. Foundation systems.  Foundation systems as specified in relevant Specialty Codes are not applicable to the construction of floating homes. Floating Homes must be supported on floatation systems designed in accordance with provisions specified in Section 28.06.030 and Section 28.06.040. Floating homes must be securely anchored to the float on which they are constructed using an engineered connection system designed to prevent the home from being dislodged or overturned.

2. Framing. Framing lumber must comply with the requirements of Subsection 28.06.020 A.

3. Allowable alternatives.  Recognizing the unique history and traditions associated with floating homes the following alternatives to the requirements specified in the relevant Specialty Codes are allowed without appeal:

a. Exterior wall and opening protection must be as described in Section 28.06.050 based on the separation between structures in a moorage.

b. Sleeping loft.  In a floating home or combo-structure and within individual dwelling units in a floating structure containing three or more dwelling units, a sleeping loft or accessory living area such as a den, office, hobby room or similar area that is not more than 250 square feet in area that is located above the level of the main floor of a floating home may use the following standards:

(1)  Access to the loft space may be by a "ship's ladder" type of stair having a rise not to exceed 12 inches and a run of not less than six inches or an alternating tread device as specified in the relevant Specialty Codes. Width of stairs or alternating tread device must be a minimum of 30 inches. Handrails must be provided at both sides of stair or alternating tread device. Headroom at stair or alternating tread device must be not less than six feet six inches at any point.

(2)  A loft space need not be provided with exterior openings for natural light, ventilation or emergency escape and rescue provided the loft area is open and unobstructed to the floor below, except for columns and posts and railings not more than 42 inches high, and the floor below onto which the loft opens has exterior openings equal to the total required for the floor area served and the loft.

c.   Porthole assemblies, whether new or salvaged, may be installed in a floating home to enhance the nautical character of the structure. Such assemblies need not comply with the energy conservation requirements of the specialty code provided the total area of all such assemblies installed does not constitute more than two percent of the total exterior wall area of the floating home. Such assemblies may be used to meet the required area for natural light and, if openable, to satisfy the required natural ventilation. Such assemblies may not be used to satisfy the required emergency escape and rescue requirements from sleeping areas.

B.  Floating structures for use and occupancy as other than floating homes, combo-structures, boathouses or tender houses accessory to a floating home must be constructed and maintained in compliance with the requirements of the relevant Specialty Codes and of Titles 24, 28, and 29 of this Code.

1.  Foundation systems.  Foundation systems as specified in the relevant Specialty Code are not applicable to the construction of floating structures. Floating structures must be supported on floatation systems designed in accordance with provisions specified in Section 28.06.030 and Section 28.06.040.  Floating structures must be securely anchored to the float on which they are constructed using an engineered connection system designed to prevent the structure from being dislodged or overturned.

2.  Framing.  Framing lumber must comply with the requirements of Subsection 28.06.020 A.

3.  Allowable alternatives.  Recognizing the unique history and traditions associated with floating structures the following alternatives to the requirements specified in the relevant Specialty Codes are allowed outright without appeal.

a.  Exterior wall and opening protection must be as described in Section 28.06.050 based on the separation between structures in a moorage.

b.  A loft, mezzanine or accessory area such as a private office, employee work room or similar area that is not more than 250 square feet in area, that is accessible to employees only and that is located above the level of the main floor of a floating structure may use the following standards:

Exception:  Loft spaces within individual dwelling units in floating structures containing three or more dwelling units will be permitted to comply with the provisions of Section 28.06.055 A.3.b.

(1)  Access to the loft space will be permitted to be a "ship's ladder" type of stair having a rise not to exceed 12 inches and a run of not less than six inches or an alternating tread device as specified in the relevant Specialty Codes.  Width of stairs or alternating tread device must be a minimum of 30 inches.  Handrails must be provided at both sides of stair or alternating tread device.  Headroom at stair or alternating tread device must be not less than six feet six inches at any point.

(2)  A loft space need not be provided with exterior openings for natural light or ventilation provided the loft area is open and unobstructed to the floor below, except for columns and posts and railings not more than 42 inches high, and the floor below onto which the loft opens has exterior openings equal to the total required for the floor area served and the loft.

c. Porthole assemblies, whether new or salvaged, may be installed in a floating structure to enhance the nautical character of the structure.  Such assemblies need not comply with the energy conservation requirements of the specialty code provided the total area of all such assemblies installed do not constitute more than five percent of the total exterior wall area of the floating structure.  Such assemblies may be used to meet the required area for natural light and, if openable, to satisfy the required natural ventilation.

4. Where the relevant Specialty Codes would require two exits be provided from a structure or occupancy within a structure, such exits must be separated as required by the Specialty Code.  The point of exit discharge for the exits must comply with the following:

a. The exits must discharge directly to a main walkway at two separate locations located as far apart as is practicable; or,

b. The exits must discharge to two separate fingerfloats or walks located on opposite sides of the structure.  Fingerfloats must each have direct and independent access to a main walkway.  Walks must each have direct and independent access to a fingerfloat or main walkway.  The point of exit discharge onto the walk may not be more than 50 feet travel distance from the point of access to the main walkway; or,

c. The exits must discharge to a continuous walk that encircles the structure on at least three sides and that provides the capability for exiting in two directions along the walk to one of two separate and distinct locations where the walk accesses the main walkway.

d. Walks need not exceed the width specified in Section 28.60.060 unless the occupant load served by the walk exceeds 150 persons.