For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 500.010 — Development standards

Salem Revised Code, City of Salem, Oregon (Supp. No. 26: codified through Ordinance No. 10-26, adopted August 10, 2026) · Salem Revised Code § 500.010

Corpus is an independent public-information project, not the official City of Salem website. Stable reference: corpuslaw.us/code/78354106-9f34-4ce3-9b6f-ad4b0d4ad413

Sec. 500.010. - Development standards.

Development within the EFU zone must comply with the development standards set forth in this section. (a) Lot standards. Lots within the EFU zone shall conform to the standards set forth in Table 500-2. TABLE 500-2. LOT STANDARDS Requirement | Standard | Limitations & Qualifications Lot Area All uses | Min. 75 acres Lot Width All uses | None Lot Depth All uses | None Street Frontage All uses | None (b) Setbacks. Setbacks within the EFU zone shall conform to the setback, lot coverage, and height standards set forth in Table 500-3. TABLE 500-3. SETBACKS Requirement | Standard | Limitations & Qualifications Abutting Street Buildings All uses | Min. 12 ft. Accessory Structures Accessory to single family | None | Applicable to accessory structures not more than 4 ft. in height. Min. 12 ft. | Applicable to accessory structures greater than 4 ft. in height. Accessory to all other uses | Min. 12 ft. Interior Front Buildings All uses | Min. 12 ft. Accessory Structures Accessory to all uses | Min. 12 ft. Interior Side Buildings All uses | Min. 5 ft. | Applicable to buildings not more than 35 ft. in height. Min. 5 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. | Applicable to buildings greater than 35 ft. in height. Accessory Structures Accessory to single family | None | Applicable to accessory structures having at least 1 wall which is an integral part of a fence. Min. 5 ft. | Applicable to all other accessory structures. Accessory to all other uses | Min. 5 ft. | Applicable to accessory structures not more than 35 ft. in height. Min. 5 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. | Applicable to accessory structures greater than 35 ft. in height. Interior Rear Buildings All uses | Min. 14 ft. | Applicable to any portion of a building not more than 15 ft. in height. Min. 20 ft. | Applicable to any portion of a building greater than 15 ft. in height. Accessory Structures Accessory to single family | None | Applicable to accessory structures not more than 9 ft. in height. Min. 1 ft. for each 1 ft. of height over 9 feet. | Applicable to accessory structures greater than 9 ft. in height. Accessory to all other uses | Min. 14 ft. | Applicable to any portion of an accessory structure not more than 15 ft. in height. Min. 20 ft. | Applicable to any portion of an accessory structure greater than 15 ft. in height. (c) Lot coverage; height. Buildings and accessory structures within the EFU zone shall conform to the setback, lot coverage, and height standards set forth in Table 500-4. TABLE 500-4. LOT COVERAGE; HEIGHT Requirement | Standard | Limitations & Qualifications Lot Coverage Buildings and Accessory Structures All uses | No Max. Rear Yard Coverage Buildings All uses | N/A Accessory Structures Accessory to all uses | No Max. Height Buildings and Structures Agriculture, forestry, and keeping of livestock and other animals | No Max. All other uses | Max. 35 ft. Accessory Structures Accessory to agriculture, forestry, and keeping of livestock and other animals | No Max. Accessory to single family | Max. 15 ft. Accessory to all other uses | Max. 35 ft.

(Prior Code, § 500.010; Ord. No. 31-13)

Ask a question about Salem law

Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.