For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 532.020 — Development standards

Salem Revised Code, City of Salem, Oregon (Supp. No. 26: codified through Ordinance No. 10-26, adopted August 10, 2026) · Salem Revised Code § 532.020

Corpus is an independent public-information project, not the official City of Salem website. Stable reference: corpuslaw.us/code/5d5ebb79-acff-4226-acb6-30e502e6b585

Sec. 532.020. - Development standards.

Development within the NH zone must comply with the development standards set forth in this section. (a) Lot standards. Lots within the NH zone shall conform to the standards set forth in Table 532-2. TABLE 532-2: LOT STANDARDS Requirement | Standard | Limitations & Qualifications Lot Area Single family | Min. 1,500 sq. ft. | Applicable to townhouses. Min. 4,000 sq. ft. | Applicable to all other single family. Two family | Min. 4,000 sq. ft. Three family | Min. 5,000 sq. ft. Four family and multiple family | Min. 7,000 sq. ft. Nonprofit shelters | Min. 4,000 sq. ft. | Applicable to nonprofit shelters serving victims of domestic violence. Min. 6,000 sq. ft. | Applicable to all other nonprofit shelters. All other uses | Min. 4,000 sq. ft. Infill lot | Min. 5,500 sq. ft. | Applicable to all infill lots, unless a greater minimum lot area is required for the specific use. Lot Width Single family | Min. 20 ft. | Applicable to townhouses. Min. 40 ft. | Applicable to all other single family. All other uses | Min. 40 ft. Lot Depth Single family | Min. 70 ft. Min. 120 ft. | Applicable to double frontage lots. No Max. | Applicable to townhouses. Max. 300% of average lot width | Applicable to all other single family. All other uses | Min. 70 ft. Min. 120 ft. | Applicable to double frontage lots. Max. 300% of average lot width Street Frontage Single family | Min. 20 ft. | Applicable to townhouses. Min. 40 ft. | Applicable to all other single family. Min. 30 ft. | Applicable to all other single family, excluding townhouses, when located on lots fronting on the turnaround of a cul-de-sac street or the outside curve of a curved street having a radius of 200 feet or less and a direction change of 60 degrees or more. In no case shall the lot width be less than 40 ft. at the front building setback line. Two family, three family, four family, and multiple family | Min. 40 ft. Min. 30 ft. | Applicable to lots fronting on the turnaround of a cul-de-sac street or the outside curve of a curved street having a radius of 200 feet or less and a direction change of 60 degrees or more. In no case shall the lot width be less than 40 ft. at the front building setback line. All other uses | Min. 40 ft. (b) Setbacks. Setbacks within the RS zone shall be provided as set forth in Table 532-3. TABLE 532-3: SETBACKS Requirement | Standard | Limitations & Qualifications Abutting Street Buildings Multiple family | Min. 10 ft. All other uses | Min. 12 ft. Min. 20 ft. | Applicable along collector or arterial streets. Accessory Structures Multiple family | Min. 10 ft. Accessory to all other uses | None | Applicable to accessory structures not more than 4 ft. in height. Min. 12 ft. | Applicable to accessory structures greater than 4 ft. in height. Min. 20 ft. | Applicable to accessory structures greater than 4 ft. in height, when located in a yard adjacent to a collector or arterial street. Interior Front Buildings Multiple family | Min. 10 ft. All other uses | Min. 12 ft. Accessory Structures Multiple family | Min. 10 ft. Accessory to all other uses | None | Applicable to accessory structures not more than 4 ft. in height. Min. 12 ft. | Applicable to accessory structures greater than 4 ft. in height. Interior Side Buildings Single family | Min. 5 ft. | Applicable to new buildings, other than zero side yard dwellings and townhouses. Min. 3 ft. | Applicable to existing buildings, other than zero side yard dwellings and townhouses. Per SRC 700.085 | Applicable to townhouses. Per SRC 700.095 | Applicable to zero side yard dwellings. Two family, three family, four family, multiple family, and all uses subject to SRC 532.020(F) | Min. 5 ft. | Applicable to new buildings. Min. 3 ft. | Applicable to existing buildings. All other uses | Min. 5 ft. | Applicable to buildings not more than 35 ft. in height. Min. 5 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. | Applicable to buildings greater than 35 ft. in height. Infill lot | Min. 10 ft. | Applicable to buildings not more than 35 ft. in height where the interior side setback abuts lots zoned RA and RS. Min. 10 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. | Applicable to buildings greater than 35 ft. in height where the interior side setback abuts lots zoned RA or RS. Min. 5 ft. | Applicable to buildings not more than 35 ft. in height where the interior side setback abuts lots zoned other than RA or RS. Min. 5 ft., plus 1 ft. for each 1 ft. of height over 35 ft., but need not exceed 20 ft. in depth. | Applicable to buildings greater than 35 ft. in height where the interior side setback abuts lots zoned other than RA or RS. Accessory Structures Accessory to all uses; infill lot | None | Applicable to accessory structures having at least 1 wall which is an integral part of a fence. Min. 5 ft. | Applicable to all other accessory structures. Interior Rear Buildings Multiple family | Min. 10 ft. All other uses | Min. 14 ft. | Applicable to any portion of a building not more than 1 story in height. Min. 20 ft. | Applicable to any portion of a building greater than 1 story in height. Accessory Structures Multiple family | Min. 10 ft. Accessory to all other uses | None | Applicable to accessory structures not more than 9 ft. in height. Min. 1 ft. for each 1 ft. of height over 9 ft. | Applicable to accessory structures greater than 9 ft. in height. Min. 1 ft. | Applicable to accessory structures adjacent to an alley, unless a greater setback is required based on the height of the accessory structure. Abutting Waterway Buildings Single Family | Min. 100 ft. | Applicable to townhouses constructed after March 16, 2022. None | Applicable to all other single family. All other setbacks required abutting streets and interior front, side, and rear property lines still apply. Two family, three family, four family, and multiple family | Min. 100 ft. | Applicable to new buildings constructed after March 16, 2022. Existing buildings constructed prior to March 16, 2022 located within the 100-foot setback may be rebuilt in the same location within the same building footprint. All other uses | None | All other setbacks required abutting streets and interior front, side, and rear property lines still apply. Accessory Structures Accessory to all uses | None | All other setbacks required abutting streets and interior front, side, and rear property lines still apply. (c) Lot coverage; height. Buildings and accessory structures within the NH zone shall conform to the lot coverage and height standards set forth in Table 532-4. TABLE 532-4: LOT COVERAGE; HEIGHT Requirement | Standard | Limitations & Qualifications Lot Coverage Buildings and Accessory Structures All uses | Max. 60% Rear Yard Coverage Buildings All uses | N/A Accessory Structures Accessory to single family and two family | Max. 25% Accessory to all other uses | No Max. Height Buildings Multiple family | Max. 25 ft. or two-stories, whichever is greater | Two-story building height shall not exceed 35 ft. All other uses | Max. 35 ft. | Applicable to new buildings. Max. 28 ft. or existing building height, whichever is greater | Applicable to existing buildings. Accessory Structures Accessory to all uses | Max. 15 ft. (d) Maximum square footage for all accessory structures. In addition to the maximum coverage requirements established in Table 532-4, accessory structures to single family and two family uses shall be limited to the maximum aggregate total square footage set forth in Table 532-5. TABLE 532-5: MAXIMUM SQUARE FOOTAGE FOR ALL ACCESSORY STRUCTURES Main Building Gross Area | Maximum Aggregate Total Square Footage for All Accessory Structures 1,200 square feet or less | 600 sq. ft. Greater than 1,200 square feet | 1,000 sq. ft. or 50% of main building gross area, whichever is less (e) Development standards for continued uses. Buildings or structures housing a continued use may be structurally altered or enlarged, or rebuilt following damage or destruction, provided such alteration, enlargement, or rebuilding complies with the following standards: (1) The altered, enlarged, or rebuilt building or structure shall conform to development standards set forth in this chapter, and to all other applicable provisions of the UDC. (2) Any building or structure altered or enlarged shall not exceed the square footage and height of the original building or structure by more than 20 percent. (3) Any building or structure rebuilt shall be located on the same location on the lot as the original building or structure, or in compliance with the setbacks set forth in Table 532-3. The square footage and height of the rebuilt building or structure shall not exceed the square footage and height of the original building or structure by more than 20 percent. (f) Additional development standards. Where a use is allowed subject to the provisions of this subsection, development containing that use shall conform to the additional development standards set forth in this subsection. (1) Maximum square footage. Each establishment shall be limited to no more than 4,000 square feet of total floor area. This provision does not apply to a dwelling unit that has been legally converted to a nonresidential use subsequent to its construction as a dwelling unit. (2) Screening. A minimum six-foot tall sight-obscuring fence or wall shall be provided along the interior side and interior rear property lines abutting a residential zone. (3) Storage. (A) Outdoor storage of materials and equipment is prohibited. (B) On-site storage of hazardous materials, including, but not limited to, those that are toxic, explosive, noxious, combustible, or flammable, is prohibited. (4) Locations of off-street parking. (A) Except as provided in subsection (B) of this section, off-street surface parking areas and vehicle maneuvering areas shall be located behind or beside buildings and structures. Off-street surface parking areas and vehicle maneuvering areas shall not be located between a building or structure and a street. (B) Existing off-street parking spaces within the NH zone established prior to August 24, 2022, but which would otherwise be made non-conforming by this chapter, may continue to be used as off-street parking spaces. (5) Primary building entrance. A primary building entrance to the nonresidential use shall face a street, with direct pedestrian access to the adjacent sidewalk. This provision does not apply to a dwelling unit that has been legally converted to a nonresidential use subsequent to its construction as a dwelling unit. (6) Hours of operation. Establishments shall not be open for business earlier than 7:00 a.m. and shall close no later than 9:00 p.m. (7) Delivery vehicles. Delivery and pick-up of materials in connection with establishments shall be made by vehicles not exceeding two axles in size and shall be prohibited earlier than 7:00 a.m. and later than 7:00 p.m.

(Ord. No. 11-22, § 1(Exh. A), 7-25-2022, eff. 8-24-2022)

Ask a question about Salem law

Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.