§ 350-27 — Blocks and streets
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 350-27
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/e5d2b14c-1875-42a9-b9af-5cfc41002bbc
§ 350-27: Blocks and streets.
A. Block layout. An interconnected system of streets and blocks is required for all MPD sites. (1) Block size. Block length must be no more than 600 feet, with a maximum perimeter of 1,800 feet, except as follows: (a) Blocks with natural or existing site constraints, such as those abutting rail corridors, highways, steep grades, and waterways, may be longer. (b) Where blocks are longer than 700 feet, pedestrian access easements, minimum 20 feet in width with minimum five-foot sidewalks, must be located approximately mid-block, effectively reducing the resulting pedestrian blocks to dimensions less than the block sizes defined in Subsection A(1), above. (2) Access points. An access point is a new street connecting to an existing street. A minimum of two access points must be provided for the MPD, with a minimum of one per every 1,500 feet of boundary, except along rail corridors, waterways, steep grades, or limited access highways. (3) Extend existing streets. Streets must connect and continue existing streets from adjoining areas. Future connections must be considered and temporary dead-end streets may be supplied for future extension with City Engineer approval. (4) Shape of blocks. The shape of a block should be generally rectangular in order to accommodate typically rectilinear buildings, but may vary due to natural features or site constraints. (5) Civic space frontage. Refer to § 350-28 for civic space requirements, including street frontage requirements. Open space, existing and new, shall be fronted with streets to provide more visibility and access. (6) Culs-de-sac. Culs-de-sac streets are prohibited, except when approved by the Planning Commission due to the presence of natural features or site constraints, including but not limited to waterways, or highways. If approved, pedestrian connections and landscape plantings may be required. (7) Lot configuration. All lots must have frontage along a street per the building type requirements, unless otherwise specified. See Article 4 of Chapter 660, Zoning, for building types and lot size requirements. (a) Blocks must have lots fronting on at least two street faces, preferably the longest faces, with the exception of blocks containing open space or civic space. See Article 4 of Chapter 660, Zoning, for building type regulations regarding double-frontage lots. (b) Flag lots, located on the interior of the block with street frontage only for driveway access, are prohibited except when approved by the Planning Commission due to topography or natural feature constraints. (c) Regulations for anticipated building types shall be considered when setting block depth and width to avoid the need for future variances. (d) Consider lot and block orientation for maximum energy efficiency, depending on the building type. For example, block orientation along an east-west longitudinal axis will encourage development of long mixed-use buildings oriented along an east-west axis, with smaller east and west facing facades, able to take advantage of passive solar technology. (8) Service access. The configuration of the lots and blocks must include alleys or service drives per § 350-27C to accommodate parking and garage access, refuse and recycling pickup, and utilities in the rear of lots. (9) Existing lots. Blocks may be established to include already existing lots within them and those lots may retain their existing zone designation. (10) Vistas. Views down streets that terminate at parcels (referred to as "vistas" in these regulations), including where a street might angle at less than 90°, must be considered when laying out streets and blocks, and locating open space, parking, and buildings. B. Street configuration. Complete streets provide for multiple modes of access throughout the City. All streets, whether publicly dedicated or privately held, must meet the following requirements. (1) Base street requirements. The base street type is illustrated in Figure 3.290-A. The City Engineer may require additional street right-of-way or other configuration based on existing context and circulation needs. The base street defines the minimum components of any new street on the interior of the development and includes the components outlined in this § 350-27B. Figure 3.290-A. Typical Base Street [image] (2) Streetscape. (a) Nonresidential streetscape width. The minimum dimension required for streetscapes along nonresidential ground stories is 14 feet, with a clear sidewalk width of at least six feet and a minimum eight-foot street tree buffer zone. (b) Residential streetscape width. Along residential ground stories, the minimum is 12 feet with a clear sidewalk of at least five feet and a minimum seven-foot street tree buffer. (c) Landscape. See § 350-13 for streetscape area regulations, including references to sidewalk and street tree regulations. Enhanced streetscape is required adjacent to any storefront area. (3) Travel lanes and pavement width. Pavement width must accommodate travel lanes, on-street parking, and any on-street bicycle accommodations. (a) Travel lanes. Travel lanes of 10 feet are required, except the following may be approved by the Planning Commission with recommendation of the City Engineer: [1] Shared lane. A shared, single sixteen-foot two-way travel lane for local residential streets within N Zones and appropriately spaced pull-offs to allow vehicles to pass are provided. (Pull-offs may include fire hydrant, no-parking zones where on-street parking is provided.) [2] One way. [3] Narrow street. A shared, single twelve-foot two-way travel lane for local residential streets with N4 or N5 Zones abutting both sides, and appropriately spaced pull-offs to allow vehicles to pass are provided. (b) On-street parking. On-street parking provides convenient parking for businesses and for parks and open space users, decreases the need for off-street parking, and buffers pedestrians on the sidewalk from vehicular traffic on the street. [1] On-street parking must be provided on both sides of the street. If only one lane of on-street parking is approved, the minimum pavement width for a two-way street is 30 feet and the minimum right-of-way width is 54 feet. [2] Minimum width of on-street parking is eight feet, except where N Zones abut the street, minimum width is seven feet. [3] Back-in or head-in angled parking is acceptable in lieu of parallel parking with additional width to the right-of-way. (c) Maximum pavement width. The maximum crossing width for all streets internal to the development is 38 feet. Wider pavement widths must include a median in the middle to provide pedestrian refuge and/or bulb-outs to reduce the crossing widths to less than 38 feet, as determined by the City Engineer. (4) Mid-block pedestrian paths. Where the maximum block size is exceeded as allowed per § 350-27A(1), mid-block pedestrian paths are required. (5) Street crosswalks. Crossings at all street intersections shall include a clear pedestrian path across streets (crosswalks) with accessibility ramps at curbs, demarcated by paint, stamped patterns, or pavers. Raised crosswalks are required for upland connections crossing streets to waterfront access (see § 350-15). (6) Curb radii. Intersections must be designed for actual turning radius of the typical design vehicle as opposed to the maximum design vehicle. Small curb radii at intersections shorten pedestrian crossing distances and reduce vehicle turning speeds, increasing pedestrian safety. See Figure 3.290-B for illustration. (a) Where on-street parking is provided with no bulb-out, a radius no greater than 10 feet is required. (b) Where on-street parking is provided with a bulb-out or where no on-street parking is provided, a radius no greater than 15 feet is required. (c) Adjacent to I Zones, a radius no greater than 25 feet is required. Figure 3.290-B. Illustration of Actual Turning Radius vs. Curb Radius [image] (7) Bicycle accommodations. New streets within the development shall accommodate bicycle access per the City's most recent comprehensive or bicycle plan. Bicycle accommodations shall be included on through streets and higher activity streets. On non-commercial and lower activity streets, bicycles may share vehicular lanes. Refer to the City's complete streets manual for further details. C. Alleys or service drives. (1) Alleys or service drives (see Figure 3.290-C must be provided through all blocks to provide vehicular access, refuse and recycling, and service access to all lots, except as follows: (a) Parking drives. Parking lot drives and parking structure drives may serve as alleys if the drive is continuous through the block with at least two access points and serves all lots on the block. (b) Single access. A single point of access is allowed where a parking structure requires only one access and the access is located off a side street. (c) Constraints. Where natural or existing site constraints (e.g., a waterway, rail line, or highway) limit the block depth and no more than two vehicular access points are provided for the lots on the block, alleys and service drives are not required. (2) Alleys or service drives must be located within boundary lines on the plan with a minimum width of 20 feet and a minimum pavement width of at least 12 feet. See Figure 3.290-C. Figure 3.290-C. Typical Alley or Service Drive [image] D. Front street designation. The orientation and location of buildings on lots is determined by the front street designation. Many building type requirements are specific to the front street abutment. Front streets are treated as the front of the building. (1) Minimum designation. A minimum of 45% of a combination of the new streets centerlines on the MPD and existing streets fronting the development must be designated as front streets. (2) Building frontage. Front streets must be designated so that all building lots abut at least one front street, except up to 20% of the lots may front a side street. (3) Civic space frontage. Where practicable, streets along civic space, required per § 350-28, must be designated as front streets to ensure building fronts face the civic space. (4) Alleys, driveways, and service access. (a) Driveways and service access. Driveways and service access to lots must not be located off a front street, unless otherwise allowed by building type. (b) Alleys. Alleys providing access to more than two lots may be located off a front street. Otherwise, alley access off a front street should be avoided. (c) No side street. When the parcel is fronted by more than two front streets and/or there is no side street or alley access, the City Engineer must designate which street may have driveway and service access. See § 660-18K of Chapter 660, Zoning, for front streets in building types. (5) Major streets. When the development abuts a street with a right-of-way wider than 120 feet, one of the following layouts may be utilized to create slower, more accessible, and more walkable streets for fronting commercial or mixed-use buildings than the major street might provide: (a) Perpendicular. A new front street located generally perpendicular to the existing major street. (b) Frontage street. A new front street located essentially parallel to the major street with a landscape buffer island or boulevard median of at least 10 feet separating the streets.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
