§ 350-34 — Final plans
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 350-34
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/061d1881-26a7-411f-826d-ce224c46e217
§ 350-34: Final plans.
A. Project narrative. Final plans must be accompanied by a project narrative, in accordance with § 350-31. B. Format. The final plan of a proposed land development must be clearly and legibly drawn to scale with sheet sizes not to exceed 24 by 36 inches except where special approval is obtained from the City Engineer. Reproducible mylar (or equivalent material) shall be the only acceptable material as a base for the final plan. If the final plan requires more than one sheet, a key diagram showing the relative location of the several sections must be shown on each sheet. C. Plan detail. The final plan must contain five groups of information: title block, location map, development design, engineering drawings, and certifications. Where noted, or where appropriate, data must be on supplementary sheets. The specifications for each group are as follows: (1) Title block. (a) The name of the development and the notation "final plan." (b) Name and address of the record owner of the tract, and the name, address, registration number and seal of the registered professional pursuant to § 350-34C who prepared the plan. All final utility plans must be prepared by a registered professional engineer unless this requirement is waived by the City Engineer for minor extensions. (c) North point, graphic scale, written scale, and date; including month, date, and year that the original drawing was completed, and the month, date, and year that the original drawing was revised, for each revision. (d) The name of the municipality, the ward, and the tax map sheet, block, and lot number corresponding to the development. (e) The total acreage, street acreage, residential lot acreage, acreage in other uses, lineal feet of streets, number of lots, number of dwelling units, and average lot size (residential acreage divided by the number of lots). (f) The recorded Deed Volume and Page Number or Docket ID Number and Lehigh County parcel number of the land to be subdivided. (2) Location map. A location map must be placed on the final plan, for the purpose of locating the property being developed, differentiated by tone or pattern and drawn at a scale large enough to show the development's relationship to existing community facilities and features such as traffic arteries, schools, recreation areas, shopping areas, and industrial areas. (3) Development design scheme. The proposed development must be shown on the design scheme as follows: (a) Total tract boundary lines of the area being developed with accurate distance to hundredths of a foot. Relative error of traverse closure, based on measurements taken in the field, must have no more than one lineal unit between beginning and ending points for each 20,000 units of the traverse distance (that is, a closure of one foot in 20,000 feet or better). (b) Location, elevation, and description of all monuments in reference to existing monuments or landmarks or the nearest established street line, including true angles and distances to such reference points or monuments. (c) The name, cartway and right-of-way width, and accurate location of all existing and proposed streets, within and adjacent to the proposed land development. (d) Whenever a developer proposes to establish a street or streets which shall not be offered for public dedication; such street must fully conform to City specifications. (e) Building setback lines along each street, with dimensions showing setback for the street right-of-way. (f) Name of record owner and all adjoining property owners. (g) Blocks and lots must be properly dimensioned and numbered. (h) A statement of the intended use of all nonresidential lots. (i) A statement of such current or previously imposed deed restrictions, including building setback lines, as may be imposed upon the property as a condition to sale. (j) All easements or rights-of-way where provided for or owned by public utilities or services and any limitations on such easements or rights-of-way. (k) Location, size, and invert elevations of all sanitary and/or storm sewers and location of all manholes, inlets, and catch basins, other appurtenances and detention facilities and best management practice (BMP) devices (when required by the City Engineer). (l) Existing and proposed contours at five-foot intervals on slopes averaging 10% or greater, at two-foot intervals for land of 3% to 10% and one-foot intervals for land of less than 3%. All contour elevations must be based on City data. Existing contours should be represented by dashed lines; proposed contours should be solid lines. Heavier solid lines should be at ten-foot intervals. (m) Existing zoning regulations, including zone designations, requirements for lot sizes and front yards, and any zoning boundary lines traversing the proposed development. (n) Any changes in existing zoning requested by the developer. (o) Sufficient data where the proposed land development lies partially or completely in a certified floodplain area, or where the proposed land development borders on a floodplain area. In this event, the final plan must delineate the FEMA-mapped 100-year floodplain boundaries and include detailed information giving the final location and elevation of proposed roads, public utilities and building sites. All such plans must show contours at intervals of two or five feet, depending on the slope of the land, and must identify accurately the boundaries of the flood-prone area. Additionally, information must be submitted concerning the 100-year flood elevations, proposed lots and sites, fills, flood or erosion protective measures, and areas subject to special deed restriction. All development encroaching into the FEMA-mapped 100-year floodplain must comply with Chapter 298, Flood Control, and obtain a floodplain development permit. (p) On the basis of standards promulgated by the Pennsylvania Department of Environmental Protection, the developer must submit, as part of the final plan, final computations of the average daily quantity and quality of the sanitary sewage flow. Additionally, the developer must submit data indicating the ability of the sanitary sewage system to accommodate discharge from the development to the City treatment plant. (q) Landscape plans. In final form, in accordance with the standards promulgated in the prevailing Chapter 597, Trees, Article I, Shade Trees. (r) A house numbering plan in accordance with the plans on file in the office of the City Engineer. (s) Delineate City boundary lines where the development is adjacent to or divided by the City line. (4) Engineering drawings. The engineering drawings, in the final form, which must be submitted on supplementary sheets are: (a) Typical street cross-section drawing for all proposed streets. (b) Existing and proposed grades must be shown along curb lines of all existing and proposed streets at a scale of one inch equals 100 feet. (c) Profiles along both rights-of-way lines and along the center line of each street. Such profiles must include the location of all street trees and street signs, all existing and proposed sanitary sewer mains, inlets, manholes and catch basins, and the exact location and size of all underground and overhead utilities and structures. (d) Surface drainage facilities for the tract to be developed must be sized to accommodate potential flows generated within the watershed. Plans must include final stormwater runoff calculations for said area, and the proposed method for accommodating anticipated runoff. (e) Design of bridges, catch basins, storm sewers, curbs, paving, crossovers, water mains, sanitary sewers, etc., where provided. (f) Before signing the final record plan, a grade plan mylar (or equivalent material) drawn to scale of one inch equals 100 feet must be approved by the City Engineer and recorded in that office. (5) Certifications. The following certifications must be inscribed and signed on the final plan: (a) Certification of ownership of record and dedication. (b) Surveyor's certification. (c) Certification of Planning Commission approval. (d) Certification of other affected municipality (if necessary). (e) Certification of review by the Lehigh Valley Planning Commission. (f) Proof of recording. (g) Certification of City Engineer. (h) Notarized signature.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.