§ 660-55 — Small wind energy conversion systems
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-55
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/2883ad62-5a08-43f8-bcd7-0c039046bca1
§ 660-55: Small wind energy conversion systems.
A. Applicability. The regulations of this section govern accessory small wind energy conversion systems. B. Where allowed. Small wind energy conversion systems are allowed as an accessory use to a lawfully established principal use in all zones, provided that such systems comply with all applicable regulations of this section. C. Height. In N Zones the height of an accessory small wind energy conversion system may not exceed the height of the principal building on the lot by more than 12 feet. The lowest point of any moving elements, such as blades or vanes, must be at least 10 feet above the ground level immediately beneath the moving element. D. Siting. Small wind energy conversion systems are subject to the setback regulations that apply to principal buildings. In addition, systems must be set back from all property lines by a distance at least equal to two times the overall height of the system, measured from grade at the base of the structure to the highest point of the system structure, which includes the tip of the top blade when the blade is in its highest position. E. Sound levels. Small wind energy conversion systems are subject to the noise regulations of Chapter 400. F. Design and operation. All small wind energy conversion systems must be equipped with manual and automatic over-speed controls to limit the blade rotation speed to within the design limits of the system. (1) The rotating turbine may not produce vibrations that are perceptible to humans standing at ground level outside the property lines of the subject lot. (2) Lattice-type towers and towers using guy wires are prohibited. (3) All power transmission and telemetry lines from a ground-mounted small wind energy conversion system to any building or other structure must be placed underground. (4) The system must include automatic devices to address high-speed winds, such as mechanical brakes and over-speed controls. (5) Towers, rotors and turbines may not be illuminated unless required by a state or federal agency, such as the FAA. (6) All structures and equipment must maintain factory colors or be finished in a non-reflective, matte finished, neutral color. (7) No commercial messages may be placed or painted on the tower, rotor, turbine, generator or tail vane that is legible from off-site. This provision is not intended to prohibit warning signs or manufacturer's logos. (8) All climbing pegs, ladders and similar apparatus on ground-mounted small wind energy conversion systems must be located at least 12 feet above the ground at the base of the structure. (9) The owner of the facility must completely remove all aboveground structures within 12 months after the system is no longer used to generate electricity. (10) Plans for minimizing bird and bat collisions with wind turbines through careful siting, blade design/color, and operational procedures (e.g., curtailment) must be submitted with the special exception application, or if special exception approval is not required, with the zoning permit application.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
