§ 660-78 — Side and rear buffers
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-78
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/4a8e4dba-960f-4ee1-b937-a848abeadbf8
§ 660-78: Side and rear buffers.
A. Intent. To minimize the impact that vehicular, outdoor storage, or loading activities have on abutting lots and to provide a transition between zones. B. Applicability. (1) Applicable lots and building types. A side and rear buffer is required along the side and rear lot lines of all lots for all building types per this § 660-78. (a) House building type. Any house, twin house, or rowhouse building type used for residential principal use is exempt from any side and rear buffer. (2) Existing conditions. (a) Existing landscape. Existing mature, healthy landscape located within or abutting the buffer area, may be substituted for any buffer requirements, provided the existing landscape sufficiently buffers the activities as determined by the Zoning Officer. (b) Existing fence. Where an existing fence in good condition meets the buffer fence requirements, the following applies: [1] The existing fence may be used to fulfill the fence requirement in the buffer. [2] Should the existing fence be removed, a new fence must be provided. [3] New fences must not be placed parallel to an existing fence on an abutting lot in order to avoid a narrow alley between the fence of a distance less than five feet. (c) Existing topography. Where existing topography either reduces the need for or increases the visibility of the buffering or the use being buffered, the Zoning Officer shall determine the extent of needed buffering and may require additional landscape material as needed to buffer the uses. C. Buffer locations. (1) Activities triggering buffers. Side and rear buffers are required where the following occurs in the rear or side yards of a lot: (a) Vehicular areas. Any vehicular areas, abutting or adjacent to zones designated in Table 660-9. Vehicular areas include such areas as parking spaces, drives, drive-through uses, fueling stations, auto sales or rental lots, truck parking, and structured parking. (b) Loading. Any loading areas abutting or adjacent to zones designated in Table 660-9. Loading areas include such areas as loading bays, loading docks, service bays, garage doors, other outdoor trucking facilities. (c) Outdoor storage uses, high-impact industry uses, and outdoor warehouse and distribution uses. The buffer B (§ 660-78F) must be installed on all lot edges surrounding outdoor storage areas (§ 660-51), high-impact industry uses (§ 660-38D), and outdoor warehouse and distribution uses (§ 660-38G), unless otherwise determined by the Zoning Officer. Buffer must comply with any use regulations in Article 5 that may exceed these regulations. (d) Other. Other outdoor activities where the Zoning Officer determines a buffer is necessary to comply with the performance standards of § 660-82. (e) Industrial zones. In IG and IM locations, the following is required: [1] The buffer B is required along the side and rear yards of all IG- and IM-zoned lots abutting an N or NX Zone regardless of vehicular activity, service, or outdoor storage areas. Buffer must comply with any use regulations in Article 5 that may exceed these regulations. [2] The Zoning Officer may require buffers between buildings and adjacent lots in zones other than N or NX Zones, if the use is determined to be of an intensity requiring buffering. (2) Location on the lot. Side and rear buffers must be installed along the lot line or the buffer may be located at the edge of the activity being buffered, provided the area between the buffer and the lot line is landscaped with ground vegetation per § 660-74 and one tree per every 2,000 square feet. (3) Access points. Driveways and other access points may interrupt buffers as necessary. D. Fence buffer. See Table 660-9 where required. See Figure 660(23) for illustration. (1) Intent. The fence is intended to provide a physical and visual separation for uses of different intensities where limited buffer area is available. (2) Buffer depth. A minimum two-foot-width buffer, measured from the lot line onto the subject lot, is required. (3) Fence, wall, or hedge. A continuous fence, wall, or shrub hedge is required on the inside perimeter of the buffer, consistent with one of the following: (a) Fence or wall option. A minimum six-foot-, maximum ten-foot-high, opaque, privacy fence or minimum six-foot, maximum eight-foot wall screening the activity must be located in the buffer adjacent to the lot line. Allowed materials include PVC, composite wood, FSC wood (cedar, redwood, or other approved by the Zoning Officer), stone, or brick. Concrete panels and concrete masonry units are not allowed, except when faced on all sides with brick or stone. (b) Shrub hedge option. An evergreen hedge screening the activity must be located in the buffer adjacent to the lot line. The hedge must consist of a single row of evergreen shrubs, minimum 24 inches in width, spaced 24 inches on center, with a height at planting of 36 inches and a mature height of at least six feet. A solid visual screen must be created within three years. (4) Curbs or wheel stops. Curbs or wheel stops must be provided along the buffer edge at any vehicular area to prevent motor vehicles from damaging the fence or hedge. Parking may not overhang into the buffer. E. Buffer A. See Table 660-9 where required. See Figure 660(24) for illustration. (1) Intent. The buffer is intended to provide physical and visual separation for uses of different intensities. (2) Buffer depth. A minimum five-foot-width landscaped buffer, measured from the lot line onto the subject lot, is required. (3) Privacy fence or hedge. See § 660-78D for the requirements of the privacy fence or hedge. (4) Shade trees. Medium or large shade trees are required at a minimum of 40 feet on center, with at least one shade tree required for each segment of buffer. (5) Landscape. The buffer area must be landscaped as planting bed. See § 660-74 for required ground vegetation regulations. F. Buffer B. See Table 660-9 where required. See Figure 660(25) for illustration. (1) Intent. The buffer is intended to provide physical and visual separation for uses of different intensities. (2) Buffer depth. A minimum ten-foot-width landscaped buffer, measured from the lot line onto the subject lot, is required. (3) Fence. (a) For outdoor storage uses and where expressly required in this chapter, an eight-foot-high security fence is required. This fence must be placed on the inside of the buffer. (b) See § 660-78D for the requirements of the privacy fence. The hedge option is not allowed. (4) Shade trees. Medium or large shade trees are required at a minimum of 40 feet on center, with at least one shade tree required for each segment of buffer. (5) Evergreen trees. Evergreen trees are required at a minimum of 20 feet on center, with at least one evergreen tree required for each segment of buffer. Evergreen trees must be at least five feet in height at planting, resulting in a complete year-round visual screen at least eight feet in height within four years of planting. (6) Landscape. The buffer area must be landscaped as planting bed. See § 660-74 for required ground vegetation regulations. Table 660-9. Side and Rear Buffer Required Abutting Zones IG, IM | IX | MX-S | MX-D, GX-D | MX-C | GX-C | MX-N, GX-N | NX, N1, N2, N3, N4, N5 | P1 | P2 Buffer Required on Lots Zoned: | IG, IM | — | — | Buffer A | Buffer A | Buffer A | Buffer A | Buffer B | Buffer B [1] | Buffer A | Buffer A IX | — | — | Fence | Buffer A | Buffer A | Buffer A | Buffer A | Buffer A | Buffer A | Buffer A MX-S | — | — | — | Buffer A | Buffer A | Buffer A | Buffer A | Buffer A | Buffer A | Buffer A MX-D, GX-D | — | — | — | — | — | Fence | Fence | Buffer A | Fence | Fence MX-C | — | — | — | — | — | Fence | Fence | Buffer A | Fence | Fence GX-C | — | — | — | — | — | — | Fence | Fence | Fence | Fence MX-N, GX-N, NX | — | — | — | — | — | — | — | Fence | Fence | Fence N1, N2, N3, N4, N5 | — | — | — | — | — | — | — | — | — | — P1 | — | — | — | — | — | — | — | — | — | — P2 | — | — | — | — | — | — | — | Buffer A | Buffer A | — See § 660-78C for activities triggering buffer requirement. [1] See § 660-78C(1)(e). Buffer B required along all side and rear yards in IG and IM at N and NX Zones. Figure 660(23) Fence | Figure 660(24) Buffer A | Figure 660(25) Buffer B [image] | [image] | [image]
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.