§ 3-901.3: Amendments to adopted code.

The following sections of the International Fire Code, 2003 edition, as adopted herein, are hereby deleted in their entirety and replaced as indicated: CHAPTER 1 – ADMINISTRATION 101.1 Title. These regulations shall be known as the "Fire Code of the City of Harrisburg," hereinafter referred to in this chapter as "this code." SECTION 103 ENFORCEMENT OF CODE 103.1 General. The City of Harrisburg, Department of Public Safety, Bureau of Fire, under the direction of the Fire Chief, and the Department of Building and Housing Development, Bureau of Codes Enforcement, under the direction of the Codes Administrator, shall jointly administer and enforce this code or any part thereof. SECTION 108 BOARD OF APPEALS This section is deleted in its entirety. See § 3-901.6 of the City's Codified Ordinances for appeal procedures. 109.3 Violation penalties. Persons who violate a provision of this code or fail to comply with any of the requirements thereof or who erect, install, alter or repair fire prevention work in violation of the approved construction documents or directive of the building official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by law. 111.4 Stop-work orders. Any person who shall continue any work on the system after having been served with a stop-work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as prescribed by law. CHAPTER 9 – FIRE PROTECTION SYSTEMS 907.2.10.5 Smoke detectors in residential structures. (a) | At least one early fire detection device (smoke detector) shall be installed in each sleeping area of any building or structure used for residential occupancy, including but not limited to single-family dwellings, multifamily dwellings, multifamily apartment houses, boardinghouses, lodging houses, rooming houses, tourist homes, bed-and-breakfast homes, dormitories, hotels, motels and residence buildings. (b) | In each multifamily apartment house of three to five units, a smoke detector shall be installed in the cellar and/or basement and on every floor of the residential structure in addition to those placed in the sleeping areas. (c) | In each multifamily apartment house containing more than five units and in each boardinghouse, lodging house, rooming house, bed-and-breakfast home, tourist home, dormitory, hotel, motel and residence building, a smoke detector shall be installed in the cellar and/or basement and on every floor in common areas (hallways, corridors, etc.) and shall be interconnected, that is, shall be wired directly to the building's power supply and shall each sound an alarm when one is activated. (d) | Where bedrooms or rooms habitually used for sleeping are separated by other use areas, such as kitchens, living rooms or dining rooms, they shall be considered as separate sleeping areas for the purposes of this section. (e) | Each smoke detector installed shall be certified by a nationally recognized inspection agency, such as Underwriters' Laboratories, Inc., as a properly operating fire detection device for the protection of life safety. (f) | It shall be the responsibility of the owner, agent for the owner or other controlling party/individual of each new and existing occupied residential occupancy unit to install smoke detectors in each residential unit as heretofore provided. Such smoke detectors shall be capable of sensing visible or invisible particles of combustion and shall be capable of producing an audible alarm upon detection thereof. (g) | It shall be the responsibility of the tenants or occupants to maintain smoke detectors. Such maintenance shall include keeping the smoke detector units serviceable by replacing batteries when necessary or by keeping them connected to an electrical source so that they remain capable of transmitting an audible signal in the presence of smoke. (h) | As an alternative to self-contained smoke detectors, an approved fire detection system may be installed. Each fire detection system must be individually approved and a permit issued by the Bureau of Fire or Codes Enforcement. (i) | In new dwelling units, smoke detectors shall be hard-wired directly to the building's power supply. In all existing dwelling units it is preferred that the smoke detectors be hard-wired to the building's power supply; however, a monitored battery supply is acceptable. (j) | At every change of occupancy of every dwelling unit occasioned by or incidental to a sale, lease or sublease of such unit, it shall be the duty of the grantor thereof (i.e., the seller, lessor or sublessor, as the case may be) to certify, before occupancy, to the new occupant that all smoke detectors required by this section or other applicable laws are installed and in proper working condition. (k) | No smoke detector or alternative system shall be directly connected (permanently wired) to the electrical system of the building or structure unless an electrical permit has first been obtained and the installation has been approved by an electrical inspector.

Ask a question about Harrisburg law

Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.