§ 1113 — SUMPS AND PUMPING SYSTEMS
The Philadelphia Code (2026 Code: The Philadelphia Code and Home Rule Charter current through October 8, 2026) · Philadelphia Code Subcode P, § 1113
Corpus is an independent public-information project, not the official City of Philadelphia website. Stable reference: corpuslaw.us/code/263c6a87-34ae-411c-a22a-7b02c17145b0
SECTION 1113 SUMPS AND PUMPING SYSTEMS
* * * P-1113.1.4 Piping. Discharge piping shall meet the requirements of Section 1102.2, 1102.3 or 1102.4 and shall include a gate full open valve and a full flow check valve. Pipe and fittings shall be the same size as, or larger than, the pump discharge tapping. Exception: In one- and two-family dwellings, only a check valve shall be required, located on the discharge piping from the pump or ejector.