R311 — MEANS OF EGRESS
The Philadelphia Code (2026 Code: The Philadelphia Code and Home Rule Charter current through October 8, 2026) · Philadelphia Code Subcode R, § R311
Corpus is an independent public-information project, not the official City of Philadelphia website. Stable reference: corpuslaw.us/code/3d9eadaa-a373-449a-973c-bd465b7ccd2c
SECTION R311 MEANS OF EGRESS
* * * [Pursuant to the UCC, delete Section R311.7.4 and replace as follows:] R-R311.7.4 Walkline. The walkline across winder treads and landings shall be concentric to the turn and parallel to the direction of travel entering and exiting the turn. The walkline shall be located 12 inches (305 mm) from the inside of the turn. The 12-inch (305 mm) dimension shall be measured from the widest point of the clear stair width at the walking surface. Where winders are adjacent within a flight, the point of the widest clear stair width of the adjacent winders shall be used. [image omitted; see the official code] FIGURE R311.7.4 WINDER TREAD AND LANDING DETAIL * * *