§ 1201.07 — Required Calculations for Lighting Installations

Pittsburgh Code of Ordinances, Pennsylvania (Code 2026-11-04: eCode360 publication current through legislation 2026-11-04 (scraped 2026-11-19)) · Pittsburgh Code § 1201.07

Corpus is an independent public-information project, not the official City of Pittsburgh website. Stable reference: corpuslaw.us/code/4701175a-f869-4ca2-a290-a7817788768a

§ 1201.07: Required Calculations for Lighting Installations.

(a) Applicability. Refer to each individual lighting metric defined in this section for applicability of defined lighting areas. (b) Purpose. Each lighting installation shall be required to submit evidence per Section 1201.09 that the intended design meets required values for lighting metrics defined under this code. (c) Illuminance (E). (1) Applicability: Class 1—Roadway, Class 2—Public Realm, and Class 4—Commercial. (2) Illumination levels, in foot-candles (FC), shall be used as the defining metric for evaluating the overall lighting levels on surfaces. (3) Required Calculations. The required levels for illuminance shall meet the listed values in Table 7—Recommended Maintained Illuminance and Luminance Values contained in this Section. Calculations shall be performed by recognized lighting software listed for this purpose. (4) Required Submission. The approved design shall clearly indicate on the submitted "Site Lighting Plan" illuminance levels measured in Footcandles (FC). Refer to Section 9 for overall submission requirements. (d) Luminance (L). (1) Applicability: Class 1—Roadway. (2) Luminance Level, in candela per meter squared (CD/M2), shall be the defining metric for evaluating surface brightness on surfaces: (3) Required Calculation. The required levels for Luminance shall meet the listed values in Table 7—Recommended Maintained Illuminance and Luminance Values contained in this Section. Calculations shall be performed by recognized lighting software listed for this purpose. (e) All exterior lighting installations shall be designed to meet the values listed in Table 7— Recommended Maintained Illuminance and Luminance Values. (1) Minimum Values. The levels presented in the table are minimum values. (2) Higher Than Minimum Value Requests. Values higher than those listed may be required due to public safety concerns. Request to exceed values listed in this chapter shall be detailed in a project specific Request For Proposal (RFP) issued by the City of Pittsburgh. Table 7—Recommended Maintained Illuminance and Luminance Values A. Roadways - Average Maintained Illuminance Values (Eavg) in Footcandles[1] Roadway Type | Pavement Reference5 | Illuminance Uniformity RatioEave to Emin R1 | R2 and R3 | R4 Expressway | Commercial | 1.0 | 1.4 | 1.3 | 3 to 1 Intermediate | 0.8 | 1.2 | 1.0 Residential | 0.6 | 0.9 | 0.8 Major | Commercial | 1.2 | 1.7 | 1.5 | 3 to 1 Intermediate | 0.9 | 1.3 | 1.1 Residential | 0.6 | 0.9 | 0.8 Collector | Commercial | 0.8 | 1.2 | 1.0 | 4 to 1 Intermediate | 0.6 | 0.9 | 0.8 Residential | 0.4 | 0.7 | 0.5 Local | Commercial | 0.6 | 0.9 | 0.8 | 6 to 1 Intermediate | 0.5 | 0.7 | 0.6 Residential | 0.3 | 0.4 | 0.4 Table 7—Recommended Maintained Illuminance and Luminance Values B. Roadways—Maintained Luminance Values (Lavg) in Candelas per Square Foot[2] Roadway Type | Average LuminanceLavg | Luminance Uniformity | Veiling Luminance Ratio(maximum)Lv to Lavg Lavg to Lmin | Lmax to Lmin Expressway | Commercial | 0.1 | 3 to 1 | 5 to 1 | 0.3 to 1 Intermediate | 0.08 | 3 to 1 | 5 to 1 Residential | 0.06 | 3.5 to 1 | 6 to 1 Major | Commercial | 0.12 | 3 to 1 | 5 to 1 | 0.3 to 1 Intermediate | 0.09 | 3 to 1 | 5 to 1 Residential | 0.06 | 3.5 to 1 | 6 to 1 Collector | Commercial | 0.08 | 3 to 1 | 5 to 1 | 0.4 to 1 Intermediate | 0.06 | 3.5 to 1 | 6 to 1 Residential | 0.04 | 4 to 1 | 8 to 1 Local | Commercial | 0.06 | 6 to 1 | 10 to 1 | 0.4 to 1 Intermediate | 0.05 | 6 to 1 | 10 to 1 Residential | 0.03 | 6 to 1 | 10 to 1 Table 7—Recommended Maintained Illuminance and Luminance Values C. Pedestrian Sidewalks And Bikeways—Average Maintained Illuminance Values (Eavg) in Footcandles[3] Walkway and Bikeway Classification | Minimum Average Horizontal Levels(Eavg) | Average Vertical Levels for Special Pedestrian Security(Eavg)2 Sidewalks (roadside) and Type A Bikeways | Commercial Areas | 1.0 | 2.2 Intermediate Areas | 0.6 | 1.1 Residential Areas | 0.2 | 0.5 Walkways distant from roadways and Type B Bikeways | Walkways, bikeways, and stairways | 0.5 | 0.5 Pedestrian Tunnels | 4.3 | 5.4 Table 7—Recommended Maintained Illuminance and Luminance Values D. Exterior Non-Defined Surface Areas—Average Maintained Illuminance Values (Eavg) in footcandles Class | Minimum Maintained Avg. Illumination | Uniformity Ratio(Ave/Min) | Maximum Trespass Pre-Curfew | Post-Curfew Ambient Lighting Levels Sky Only | 0.25 | 2.5:1 | 0.1 | 0.1 Low | 0.5 | 5:1 | 0.3 | 0.1 Medium | 1 | 5:1 | 0.8 | 0.2 High | 2 | 5:1 | 1.5 | 0.5 Table Notes for A, B, and C: 1. Lv = veiling luminance 2. Shall be calculated for areas where facial recognition is critical. 3. The relationship between individual and respective luminance and illuminance values is derived from general conditions to dry paving and straight road sections. This relationship does not apply to averages. 4. For divided highways, where the lighting on one roadway may differ from that on the other, calculations should be made on each roadway independently. 5. Pavement references are as follows: R1-Mostly Diffuse, R2-Semi Diffuse, R3-Semi Specular, R4-Specular Table 7—Recommended Maintained Illuminance and Luminance Values E. Parking Lots—Average Maintained Illuminance Values (Eavg) in Footcandles Fields of Measurement | Basic | Special Pedestrian Security Minimum Horizontal Illuminance | 0.2 | 0.5 Uniformity Ratio, Max-to-Min | 20:1 | 15:1 Minimum Vertical Illuminance | 0.1 | 0.25 Table 7—Recommended Maintained Illuminance and Luminance Values F. Recommend Maintained Illuminance for Parking Garages Minimum Horizontal2 fc | Maximum/Minimum Horizontal Uniformity Ratio3 | Minimum Vertical4 fc Basic1 | 1.0 | 10:1 | 0.5 Ramps5 | 2.0 Day6 | 2.0 | 10:1 | 1.0 Night | 1.0 | 10:1 | 0.5 Entrance Areas7 Day6 | 50 | | 25 Night | 1.0 | 10:1 | 0.5 Stairways | 2.0 | | 1.0 Notes: 1 For typical conditions. While these values are intended to address personal security issues, some retailers may increase them to further offset perceived concerns. Research has shown that, under certain conditions of limited contrast (such as concrete wheel stops on a concrete garage floor), this level is needed to provide good visibility of the wheel stop. 2 Measured on a parking surface, without any shadowing effect from parked vehicles or columns. For preliminary design, and average value of fifty (50) horizontal lux (five (5) hfc) for basic illuminance (and equivalent for other conditions) may be calculated. 3 The highest horizontal illuminance area, divide by the lowest horizontal illuminance point or area, should not be greater than the ratio shown. 4 Measured at one and one-half (1.5) meters (five (5.0) ft.) above parking surface at the point of lowest horizontal illuminance, excluding facing outward along boundaries. 5 Applies to clearway ramps (no adjacent parking) but not to sloping floor designs. 6 Daylight may be considered in the design calculation. 7 A high illumanance level for about the first twenty (20) meters (sixty-six (66) ft.) inside the structure is needed to effect a transition from bright daylight to a lower internal level.

[ Ord. No. 8-2011 , § 1, eff. 4-15-2011 ]

Ask a question about Pittsburgh law

Corpus searches the Pittsburgh sections it holds and shows the ones that match, with their citations. Free, no sign-in.