For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 914.04 — Bicycle Parking

Pittsburgh Code of Ordinances, Pennsylvania (Code 2026-11-04: eCode360 publication current through legislation 2026-11-04 (scraped 2026-11-19)) · Pittsburgh Zoning Code § 914.04

Corpus is an independent public-information project, not the official City of Pittsburgh website. Stable reference: corpuslaw.us/code/108958fc-ff62-4cd1-bc43-7697dc8f1ba4

§ 914.04: Bicycle Parking.

This section seeks to ensure the proper provision of on-site bicycle parking and amenities needed to support multimodal trips to new development. A. Special Definitions. 1. BICYCLE PARKING SPACE means a 4 feet by 6 feet space provided for locking up to 2 bicycles to a City approved Bicycle Rack or a bicycle locker that can store up to two 2 bicycles per unit. 2. BICYCLE RACK means a stationary device with a base that can wedge anchors for surface mounting, provides steel tubing 1 inch to 4 inches thick, containing locking points between 1 foot and 3 feet off the ground and a gap near the bottom for pedal clearance, enabling one to lock a bicycle frame and 1 of the wheels with a standard U-Lock. Such a rack must be able to accommodate at least 2 bicycles upright by rack frame. 3. PROTECTED BICYCLE PARKING SPACES are secure facilities which protect the entire bicycle, its components and accessories against theft and against inclement weather, including wind-driven rain. This type of facility includes, but is not limited to bicycle lockers, check-in facilities, monitored bicycle parking, restricted access parking, and personal storage. 4. UNPROTECTED BICYCLE PARKING SPACES are Bicycle Racks which permit the locking of the bicycle frame and 1 wheel to the rack and which support the bicycle in a stable position without damage to wheels, frame or components. 5. LOW OCCUPANCY FACILITY means a building or use with limited customer or non-employee contact and less than 1 employee per every 10,000 square feet of gross floor area. B. Locations and Facilities. 1. Bicycle parking shall be provided in a well-lighted area. 2. Bicycle parking shall be located in a convenient and easily accessible location with safe and convenient means of ingress and egress to bicycle parking facilities. At least 50 percent of bicycle parking spaces shall be accessible without requiring the use of stairs or an elevator from a primary or secondary entrance to the building or parking structure. 3. Bicycle Parking facilities shall not interfere with accessible paths of travel or accessible parking as required by the Americans with Disabilities Act of 1990. 4. Protected and Unprotected Bicycle Racks shall be located in highly visible areas to minimize theft and vandalism. 5. In cases of protected bicycle rooms, at least 50% of the bicycle parking spaces shall be flush ground mounted. 6. Alternative Locations and Facilities. In the event that compliance with Section 914.04.B or 914.04.C may not be feasible or ideal because of demonstrable hardship or due to a creative design alternative, the Zoning Administrator in consultation with DOMI may approve an alternative storage location or alternative compliance. The Zoning Administrator shall be guided by the following criteria: a. Such alternative facilities shall be well-lighted and secure. b. All Bicycle Parking Spaces outside of a building shall be located within a 100 foot diameter of the primary building entrance. c. Bicycle Racks may be placed in the public right-of-way provided that the building owner attains an encroachment permit for the installation of racks in the public right-of-way from the Department of Mobility and Infrastructure. Any bicycle racks placed in the public right-of-way shall be standard "u racks" in accordance with DOMI bicycle parking standards. C. Layout of Spaces. Bicycle Parking Spaces shall be laid out according to the following: 1. All bicycle parking areas shall afford a 4 foot wide access aisle to ensure safe access to spaces. 2. Bicycle parking and automobile parking shall be located so as to protect bicycles from damage. 3. In cases where Bicycle Parking Spaces are not visible from the primary street, signage shall be used to direct cyclists safely to bicycle parking areas. 4. All Bicycle Racks and lockers shall be securely anchored to the ground or building structure. 5. Bicycle Parking Spaces shall not interfere with pedestrian circulation and shall adhere to ADA requirements. 6. Bicycle parking shall be an integral part of the overall site layout and designed to minimize visual clutter. D. Bicycle Parking Requirement. Unless otherwise stated, all square footage-based bicycle parking standards shall be computed on the basis of gross floor area within the principal building. Bicycle Parking Spaces shall be provided in accordance with the following tables: 1. For all Non-Residential uses except, Hotel/Motel, Commercial Parking, Parking Structure, and Low Occupancy Facilities (as defined in Section 914.04.A.5): Gross Floor Area | Required Minimum Number of Bicycle Parking Spaces 0-5,000 s.f. | 1 5,001-10,000 s.f. | 2 Over 10,000 s.f. | 2 + 1 per 5,000 s.f. above 10,000 s.f. 2. For Residential: Residential Use Type | Required Minimum Number of Bicycle Parking Spaces Single-, Two-, and Three-unit Residential | 0 Multi-unit Residential | 1 per every 3 dwelling units or a fraction thereof (a) At least sixty (60) percent of all bicycle parking spaces provided must be Protected Bicycle Parking Spaces. (b) Senior Housing (as defined in Section 911.02) shall be permitted to reduce the required minimum number of bicycle parking spaces by up to 50%. 3. For Commercial Parking and Parking Structure uses: Number of Automobile Spaces | Required Minimum Number of Bicycle Parking Spaces 0-3 | 0 4-20 | 1 21-40 | 2 Over 40 | 1 per every 10 spaces or a fraction thereof 4. For Low Occupancy Facilities and Hotel/Motel uses: Number of Employees | Required Minimum Number of Bicycle Parking Spaces 0-5 | 0 6-20 | 1 21-80 | 2 Over 80 | 1 per every 20 employees or a fraction thereof (a) To certify a building or use as a Low Occupancy Facility, the building owner or applicant shall attach to any zoning application, an affidavit attesting to the number of employees required for the use. (b) When calculating the minimum number of Protected and/or Unprotected parking spaces required results in a fractional number, a fraction of less than one-half (1/2) shall be disregarded and a fraction of one-half (1/2) or more shall be rounded to the next highest whole number.

[ Ord. No. 31-2026 , eff. 10-29-2026 ]

Ask a question about Pittsburgh law

Corpus searches the Pittsburgh sections it holds and shows the ones that match, with their citations. Free, no sign-in.