§ 34-60 — Equipment to be enclosed by partitions; ventilation and exhaust required
Code of Ordinances of the City of Warwick, Rhode Island (Codified through Ordinance No. O-25-11, adopted July 8, 2025 (Supp. No. 32)) · Warwick Code of Ordinances § 34-60
Corpus is an independent public-information project, not the official City of Warwick website. Stable reference: corpuslaw.us/code/da5e514a-fd46-4cb5-bbb4-5ed90ab0de03
Sec. 34-60. - Equipment to be enclosed by partitions; ventilation and exhaust required.
All equipment for the maintenance and operation of such dry cleaning devices shall be enclosed by partitions and be mechanically ventilated to the outside atmosphere by devices capable of evacuating against static pressure of 0.25 water inches from such partitioned area air-drawn from that part of the premises available to the public, in the following specified quantities: Number of Machines Served by Equipment in Partitioned Area | Cubic Feet per Minute per Machine 1 to 3 | 500 4 to 8 | 400 9 to 16 | 375 17 or more | 360 The operation of both this system of exhaust and the independent ventilation system of each dry cleaning machine, as required under section 35-56, shall be maintained at all times when any self-service dry cleaning establishment is open to the public and solvent is contained in the system concerned.
(Code 1971, § 12-46)
Ask a question about Warwick law
Corpus searches the Warwick sections it holds and shows the ones that match, with their citations. Free, no sign-in.
