§ 54-506 — Exceptions to setback requirements
Code of the City of Charleston, South Carolina (Supp. No. 115: codified through Ordinance No. 2026-092, enacted May 26, 2026) · Charleston, S.C., Zoning Ordinance § 54-506
Corpus is an independent public-information project, not the official City of Charleston website. Stable reference: corpuslaw.us/code/20a232ad-32e4-4835-9d59-074c844e47e9
Sec. 54-506. - Exceptions to setback requirements.
a. Exception for cornice or roof overhangs. In measuring the width and depth of the setbacks prescribed herein, a cornice or roof overhang, projecting not more than twelve inches, or a fence or wall, shall not be held to reduce such required dimensions. b. Exception to front setback requirements. Notwithstanding the setback requirements of this Chapter, the front building line of any proposed building may be as close to the street as the front building line of the next adjacent building on the same side of the same street, either to the right or to the left, whichever is closer to the street, provided, no fence, wall, shrubbery, sign, marquee, or other obstruction to vision between the heights of three (3) feet and fifteen (15) feet shall be permitted within fifteen (15) feet of the intersection of the right-of-way lines of two streets or railroads or of a street intersection with a railroad right-of-way line. Necessary traffic and directional signs shall not be included in this requirement. c. Exception to side setback requirements in residential zones. Notwithstanding the setback requirements of this Chapter for residential zoning districts, a rear residential building addition may meet the same north or east side yard setback as the existing building onto which the addition is attached, provided that the length of the addition does not exceed a distance greater than fifty percent (50%) of the length of the existing building, and that the addition meets other applicable zoning requirements. d. Exception for porches and exterior stairs in front and rear setbacks. In all residential districts where front setbacks are required except the SR-8 district, porches or exterior stairs may be erected into the required front setback provided they are not closer than ten (10) feet to a front street line, and may be erected into the required rear setback provided they are not closer to an adjoining property line that the larger side setback requirement for that district or ten (10) feet, whichever is greater. In the SR-8 district, porches and exterior stairs may encroach into the required front setback up to ten (10) feet and may be erected into the required rear setback provided they are not closer to an adjoining property line than twelve (12) feet. e. Exception to side setback requirements for corner lots. Notwithstanding the setback requirements of this Chapter, a proposed building or buildings on any corner lot may occupy with respect to a side street line the same relative position on such line as a building removed therefrom within the preceding twelve months; provided, no fence, wall, shrubbery, sign, marquee, or other obstruction exists within the vision clearance zone (see Section 54-351). f. Exception to side and rear setback requirements for accessory buildings exceeding a footprint of 100 square feet. Notwithstanding the setback requirements of this Chapter, accessory buildings meeting all the conditions listed below, shall be allowed to encroach to within three (3) feet of interior side and rear property lines, except when those property lines abut marshes, rivers or lakes, in which case setback requirements for principal buildings relative to those abutting or encroaching property lines shall apply to all buildings. 1. Only one accessory building using this exception shall be permitted on a lot; and 2. Accessory building(s) and principal building shall meet lot occupancy requirements in Table 3.1 of Section 54-301; and 3. Accessory building shall meet accessory building setback requirements in Table 3.1 of Section 54-301; and 4. Accessory building height shall not exceed one and one-half (1½) stories and a maximum eave height of eleven (11) feet unless the principal building is two (2) or more stories, in which case the accessory building shall not exceed two (2) stories and a total height of 24 feet measured from the ground to the peak of a gable, hipped, or shed roof. For the purposes hereof, a crawl space in the principal building exceeding six (6) feet in height shall count as a story; and 5. The footprint of the accessory building (see definition for "building" in Sec. 54-120) shall not exceed 600 square feet in total area; and 6. Accessory building shall not include a dwelling unit except where additional dwelling units are permitted on the lot by this Chapter; and 7. Accessory building shall be on same lot as principal building and located to the rear of the principal building. g. Exception to side and rear setback requirements for accessory buildings not exceeding a footprint of 100 square feet. Notwithstanding the setback requirements of this Chapter, accessory buildings meeting all the conditions listed below, shall be allowed to encroach to within one and one-half (1½) feet of interior side and rear property lines, except when those property lines abut marshes, rivers or lakes, in which case setback requirements for principal buildings relative to those abutting or encroaching property lines shall apply to all buildings. 1. Only one accessory building shall be permitted on a lot; and 2. Accessory building and principal building shall meet lot occupancy requirements in Table 3.1 of Section 54-301; and 3. Accessory building shall meet accessory building setback requirements in Table 3.1 of Section 54-301; and 4. Accessory building shall be limited to one (1) story and a maximum eave height of nine (9) feet; and 5. The footprint of the accessory building shall not exceed 100 square feet in total area; and 6. Accessory building shall not include a dwelling unit; and 7. Accessory building shall be on same lot as principal building and located to the rear of the principal building; and 8. This exception shall not apply to utility platforms. h. Exception to side and rear setback requirements for utility platforms. Notwithstanding setback requirements of this Chapter, utility platforms to elevate only HVAC, generator, pool, or similar utility equipment, shall be allowed to encroach to within three (3) feet of interior side and rear property lines, except when those property lines abut marshes, rivers or lakes, in which case setback requirements for principal buildings relative to those abutting or encroaching property lines shall apply to all buildings.
(Ord. No. 2001-44, § 12, 5-8-01; Ord. No. 2005-31, § 1, 2-8-05; Ord. No. 2007-99, § 5, 5-1-07; Ord. No. 2007-172, §§ 5, 6, 9-11-07; Ord. No. 2022-192, § 2, 12-20-22; Ord. No. 2025-087, § 1, 6-17-25)
Ask a question about Charleston law
Corpus searches the Charleston sections it holds and shows the ones that match, with their citations. Free, no sign-in.
