Sec. 20-72. - Specific standards.
In all areas of special flood hazard where base flood elevation data has been provided, as set forth in section 20-30 or subsection 20-53(10), the following provisions are required: (1) Residential construction. New construction or substantial improvement of any residential structure (including manufactured homes) shall have the lowest floor elevated no lower than three feet above the base flood elevation. No basements are permitted. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with subsection (5) of this section. (2) Nonresidential construction. New construction or substantial improvement of any commercial, industrial or nonresidential structure (including manufactured homes) shall have the lowest floor elevated no lower than three feet above the level of the base flood elevation. No basements are permitted. Structures located in A-zones may be floodproofed in lieu of elevation, provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, using structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered, professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in subsection 20-53(7). A variance may be considered for wet floodproofing agricultural structures in accordance with the criteria outlined in subsection 20-56(d). Agricultural structures not meeting the criteria of subsection 20-56(d) must meet the nonresidential construction standards and all other applicable provisions of this article. (3) Manufactured homes. a. Manufactured homes that are placed or substantially improved on sites outside a manufactured home park or subdivision, in a new manufactured home park or subdivision, in an expansion to an existing manufactured home park or subdivision or in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, must be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated no lower than three feet above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. b. Manufactured homes that are to be placed or substantially improved on sites in an existing manufactured home park or subdivision that are not subject to the provisions of subsection (3)a of this section must be elevated so that the lowest floor of the manufactured home is elevated no lower than three feet above the base flood elevation, and be securely anchored to an adequately anchored foundation to resist flotation, collapse and lateral movement. c. Manufactured homes shall be anchored to prevent flotation, collapse or lateral movement. For the purpose of this requirement, manufactured homes must be anchored to resist flotation, collapse, or lateral movement in accordance with Section 19-425.39 of the State Manufactured Housing Board Regulations, effective May 25, 1990, as amended. Additionally, when the elevation would be met by an elevation of the chassis at least 36 inches or less above the grade at the sight, the chassis shall be supported by reinforced piers or other foundation elements of at least equivalent strength. When the elevation of the chassis is above 36 inches in height, an engineering certification is required. d. An evacuation plan must be developed for evacuation of all residents of all new, substantially improved or substantially damaged manufactured home parks or subdivisions located within floodprone areas. This plan shall be filed with and approved by the local administrator and the local emergency preparedness coordinator. (4) Recreational vehicles. A recreational vehicle is ready for highway use if it is on wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices and has no permanently attached additions. Recreational vehicles placed on sites shall either be on site for fewer than 180 consecutive days and be fully licensed and ready for highway use, or meet the requirements of sections 20-53, 20-71 and subsection (3) of this section. (5) Elevated buildings. New construction or substantial improvements of elevated buildings that include fully enclosed areas that are usable solely for the parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to preclude finished living space and be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: 1. Provide a minimum of two openings on different walls having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above grade; 3. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions; and 4. Fill placed around foundation walls must be graded so that the grade inside the enclosed area is equal to or higher than the adjacent grade outside the building on at least one side of the building. b. Hydrodynamic pressure must be considered in the design of any foundation system where velocity waters or the potential for debris flow exists. If flood velocities are excessive (greater than five feet per second), foundation systems other than solid foundations walls should be considered so that obstructions to damaging flood flows are minimized. c. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator). d. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms, except to enclose storage areas. (6) Temporary development. All applicants must submit to the local administrator, prior to the issuance of the development permit, a written plan for the removal of any temporary structures or development in the event of a hurricane or flash flood warning notification. The plan shall be reviewed and approved in writing, and must include the following information: a. A specified time period for which the temporary use will be permitted; b. The name, address and phone number of the individual responsible for the removal of temporary structures or development; c. The time frame prior to the event at which any structures will be removed (i.e., minimum of 72 hours before landfall of a hurricane or immediately upon flood warning notification); d. A copy of the contract or other suitable instrument with a trucking company to ensure the availability of removal equipment when needed; e. Designation, accompanied by documentation, of a location outside the floodplain to which any temporary structure will be moved; f. A determination of permanent structures which would be adversely affected by increased flooding upstream or downstream, and a method for covering the liability, such as a performance bond; and g. A plan to restore the area to its natural condition once the temporary permit expires or the temporary use is terminated, whichever is first. (7) Accessory structures. An accessory structure or garage, the cost of which is greater than $3,000.00, must comply with the elevated structure requirements of subsections (2) and (5) of this section. When accessory structures of $3,000.00 or less are to be placed in the floodplain, the following criteria shall be met: a. Accessory structures shall not be used for human habitation (including work, sleeping, living, cooking or restroom areas); b. Accessory structures shall be designed to have low flood damage potential; c. Accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters; d. Accessory structures shall be firmly anchored to prevent flotation, collapse or lateral movement of the structure; e. Service facilities such as electrical and heating equipment shall be installed in accordance with subsection 20-71(4); and f. Openings to relieve hydrostatic pressure during a flood shall be provided below base flood elevation in conformance with subsection (5) of this section. (8) Floodways. Located within areas of special flood hazard established in section 20-30, are areas designated as floodways. The floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris and potential projectiles and has erosion potential. The following provisions shall apply within such areas: a. No encroachments, including fill, new construction, substantial improvements, additions and other developments shall be permitted unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in the flood levels during the occurrence of the base flood. Such certification and technical data shall be presented to the local administrator. b. If subsection (8)a of this section is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this division. c. Stream crossings for any purpose (i.e., timber harvesting operations), if temporary, shall be permitted in accordance with subsection (6) of this section. Otherwise, the development shall comply with all applicable flood hazard reduction provisions of this division. d. No manufactured homes shall be permitted, except in an existing manufactured home park or subdivision. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring and the elevation standards of subsection (3) of this section are met. e. Permissible uses within floodways may include: general farming, pasture, outdoor plant nurseries, horticulture, forestry, wildlife sanctuary, game farm and other similar agricultural, wildlife and related uses. Also, lawns, gardens, play areas, picnic grounds and hiking and horseback riding trails are acceptable uses, provided that they do not employ structures or fill. Substantial development of a permissible use may require a no-rise certification. The uses listed in this subsection are permissible only if and to the extent that they do not cause any increase in base flood elevations. (9) Fill. Fill is discouraged because storage capacity is removed from floodplains. Elevating buildings by other methods must be considered. An applicant shall demonstrate that fill is the only alternative to raising the building to at least three feet above the base flood elevation, and the amount of fill used will not affect the flood storage capacity or adversely affect adjacent properties. The following provisions shall apply to all fill placed in the special flood hazard area: a. Fill may not be placed in the floodway unless it is in accordance with subsection (8)a. of this section; b. Fill may not be placed in tidal or nontidal wetlands without the required state and federal permits; c. Fill must consist of soil and rock materials only. Dredged material may be used as fill only upon certification of suitability by a registered professional geotechnical engineer. Landfills, rubble fills, dumps and sanitary fills are not permitted in the floodplain; d. Fill used to support structures must comply with ASTM standard D-698, and its suitability to support structures certified by a registered, professional engineer; e. Fill slopes shall be no greater than two horizontal to one vertical. Flatter slopes may be required where velocities may result in erosion; and f. The use of fill shall not increase flooding or cause drainage problems on neighboring properties.
(Ord. No. 95-2, § 410, 1-13-95; Ord. No. 08-10, § 1, 7-14-08)
Ask a question about Fort Mill law
Corpus searches the Fort Mill sections it holds and shows the ones that match, with their citations. Free, no sign-in.