For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-2.3 — Requirements in NBRD, Navy Base Redevelopment District:

Code of Ordinances of the City of North Charleston, South Carolina (Supp. No. 76: codified through Ordinance No. 2026-022, adopted June 25, 2026) · North Charleston Code of Ordinances, App. A, art. VI, § 6-2.3

Corpus is an independent public-information project, not the official City of North Charleston website. Stable reference: corpuslaw.us/code/65bdb4a4-a0e5-4c93-b7ed-1bd68e848f51

Section 6-2.3. - Requirements in NBRD, Navy Base Redevelopment District:

Prior to submission of applications for building permits, site work permits, and/or plats, an applicant must first submit a concept plan for staff review and subsequent discussion. The concept plan shall include all streets, stormwater, parking, and overall land use layout to ensure consistency with overall NBRD district intent. (a) Building placement and setbacks. 1. All streets in the NBRD shall be platted with frontages designated either as build to the front property line or build to the front set back line, as noted in the below design standards chart. These lines will be established at the time of preliminary plat submittal and shall be shown on the recorded plat. On corner lots, the accessory buildings along a street frontage must conform to the building placement requirements for that street. Street Name | Front Build-to Line | Side and Rear Setbacks* Noisette Boulevard | 46—56 feet from street center line | 10 feet All other streets | 30—35 feet from street center line | 10 feet 2. Any building or structure shall be constructed so that a minimum of eighty (80) per cent of the lot frontage is occupied by a building façade that abuts the front property line or the front set-back/build-to line. Building façade indentations or extensions which are part of the building's architectural design shall count toward the minimum eighty (80) per cent lot frontage requirement. The remaining twenty (20) per cent of the lot frontage abutting the front property line shall be occupied by an appropriate screen wall, as described in Section (c)2 below. On a corner lot the building facades shall occupy at least eighty (80) per cent of the frontage on the primary street and no less than twenty-five (25) per cent on the secondary street with the remainder of the frontage on the secondary street being occupied by an appropriate screen wall, as described in Section (c)2 below. On a corner lot, the abutting building frontages must extend to the corner or have a corner entrance. Stoops and open porches, bay windows, and balconies may extend up to four (4) feet into the right-of-way, with an encroachment permit from the city, provided at least five (5) feet of clear sidewalk passage remains. (b) Building height: In order to protect the character of the Charleston Navy Yard Historic District, as listed on the National Register of Historic Places, a height district is established as shown in the below map: [image omitted; see the official code] (c) Landscaping, fences, and walls: 1. A landscape plan must be submitted and approved prior to the issuance of any permits. The landscape plan must meet the requirements below: a. No buffers shall be required. b. Any proposed landscaping of the structure shall consist of native species that are complementary to the streetscape and surrounding development. 2. Fences or walls of 3'6" to 8'0" are required on un-built portions of build to- set-back lines or build to front property lines on street frontages a. Chain-link fencing is prohibited, as well as mesh and tarp. b. Fences and walls which face adjacent commercial properties or can be seen from the right-of-way: Façades in excess of fifteen (15) feet in length shall be adorned with either vegetative growth (vertical gardens or green walls must remain green throughout the year), decorative elements, or artistic murals, so long as the mural is not a sign or advertisement. (d) Street standards: 1. Street trees are required in order to contribute to the definition of the streetscape and will be selected to create a street canopy that provides effective shade for pedestrians and vehicles. They will be planted to provide separation of the sidewalk from the street curb. A canopy tree with a minimum caliper of six (6) inches shall be planted every fifty (50) feet within the right-of-way. Species such as Southern Red Oak, Live Oak, Willow Oak, Elm varieties, and Nuttall oaks shall be used, with tree types to be consistent within each block and evenly spaced, with exceptions made for curb cuts, utilities, and other obstructions. In a park setting, trees may be planted on the subject parcel if requested by the applicant for design flexibility at the ratio of one (1) tree per fifty (50) feet of street frontage. 2. All streets shall have a minimum four-inch vertical curb. 3. Sidewalks are required along all streets as follows: a. Noisette Boulevard: Ten (10) feet, both sides. b. All other streets: Five (5) feet, both sides. During concept review, wider sidewalks may be required by staff. 4. To the extent practicable, utility services shall be located in rear alleys. (e) Parking: 1. Parking shall not be located between a structure and a street. 2. Parking standards for the NBRD Zoning District shall be as per the chart below: Residential - Multifamily | Office/Commercial/Retail | Entertainment Alley access typical. Minimum one car parking on site required. | Alley access, internal surface lots, parking garage. 2 spaces per 1,000 GSF (1/500 sf). Parking requirements may be met by combination of on-site parking and shared parking in a public parking facility located within a radius of 1,320 feet of the parcel. | Alley access, internal lots, parking garage, one per 50 seats for non-fixed seating, one per 4 seats of fixed seating. Parking requirements may be met by combination of on-site parking and shared parking in a public parking facility located within a radius of 1,320 feet of the parcel. 3. Uses not specified in the table above shall default to the zoning regulations' prevailing parking standards. 4. On-street parking created as a part of the project may be counted toward the project's required parking. (f) Connectivity: In all cases, ease of pedestrian access between proposed developments and adjacent developments shall be required in the development of a proposed project's site and circulation plans and include pedestrian connectivity, both internally and externally to the site. Each parcel shall be developed with the intention to create a harmonious connection to the neighboring developments, whether preparing to connect with a future development or to tie into the connections that were created by the adjacent parcels' previous development. (g) Open spaces: For all commercial uses, a minimum of three (3) per cent of the development acreage shall be designed and utilized as open space and/or parks in the form of active and passive parks, plazas, or public gathering spaces for any development project. (h) Architectural character: Buildings, walls, and fences should be designed to complement the architectural character of the adjacent buildings, including materials, window patterns and spacing, ornamentation, orientation, and scale. (i) Utilities: All utilities, including, but not limited to electric utilities, telecommunications, fiber, or cable providers, shall be placed underground. All junction and access boxes shall be screened with sufficient evergreen vegetation so as to obscure them from view. All small wireless facilities shall utilize concealment elements, and disguised as a hardscaped or softscaped amenity, such as benches; flower boxes, or decorative poles when located in or adjacent to any rights-of-way. All utility pad features and meters shall be shown on the site plan and are subject to building setbacks. (j) Lighting: 1. All lighting sources, with the exception of parking area pole-mounted light fixtures, shall be shielded in order to avoid glare. Under no circumstances shall light sources be visible. Up-lighting of significant trees is strongly encouraged as is landscape lighting along walks, paths, and at plazas. 2. Architectural light fixtures and poles should blend with the architecture of the buildings. Pole-mounted fixtures are limited to poles of a maximum of fourteen (14) to sixteen (16) feet in height. Fixtures and the poles on which they are to be mounted shall be consistent in their appearance throughout the district. (k) Streetscapes: 1. Retail spaces located on ground floors must include a minimum of three (3) out of the six (6) items listed below: (i) Storefront windows (for merchandise on display which increases pedestrian interest) (ii) Stores accessible by pathways through the right-of-way (iii) Pedestrian-scale lighting (iv) Projecting signs, hanging signs, sandwich boards, corner signs, creative advertising (v) Flags and banners (vi) Sidewalk displays 2. Commercial properties must incorporate greenscapes (environmentally beneficial landscape techniques) through the inclusion of a minimum of one (1) of the four (4) items listed below: (i) Incorporate greenscaped passageways that invite people to walk and experience a livable urban environment (ii) Create park like nooks along buildings (iii) Install fountains/water features, sculptures, private gathering spots (iv) Create garden art via topiaries or planters (stand alone or wall mounted) 3. Projects must include street furniture along streets by installing a minimum of three (3) out of the five (5) items listed below. All site and street furnishings shall be of commercial grade. Submit pictures and color samples for approval. (i) Trash receptacles (ii) Bicycle racks or storage facilities (iii) Benches, tables, chairs, joggling boards (iv) Cigarette disposal stations, pet watering stations, water fountains (v) Potted plants or planter boxes (l) Signage: All signs shall meet the minimum size and height requirements specified below: 1. Wall signs and window signs (commercial): One (1) square foot of wall and window signage combined will be permitted per each linear foot of building frontage, along the entirety of the building's orientation, up to and not exceeding fifteen (15) per cent of the area of the building facade on which the sign is to be displayed. Window signage shall not exceed twenty-five (25) per cent of the window area. (i) The area of a sign shall be the total area within the smallest square, circle, rectangle, triangle or combination thereof that will encompass the extreme limits of the writing, representation, emblem, or other display, together with the total area of any material or color forming an integral part of the background of the display or used to differentiate the sign from the backdrop or structure against which it is placed, but not including any supporting framework, bracing or decorative fence or wall (ii) Area of each panel individually shall be calculated and added together to determine the total sign area (iii) A maximum of three (3) building signs shall be permitted for each business establishment on the ground floor. A maximum of two (2) building signs shall be allowed for each second-level and third-level business establishment having a facade that faces a street. For purposes of this section, "second-level and third-level" means those building floor levels immediately above sidewalk-level. The combined area of these permitted building signs shall not exceed fifteen (15) percent of the total area of the wall of the front of each said business establishment, and in no case shall any individual sign exceed 200 square feet. Notwithstanding these provisions, every business establishment shall be entitled to at least 60 square feet total combined sign area. (iv) Building signs on corner lots: For corner lots, one additional building sign for the business establishment occupying the corner space shall be permitted, provided it is oriented toward the additional street frontage. The total area of said sign shall not exceed ten (10) percent of the total area of the wall of said building occupied by such business establishment and oriented toward the additional street frontage, or sixty (60) square feet, whichever is less. (v) Multi-tenant signs: In addition to the signs otherwise authorized in this section, buildings with three (3) or more tenants shall be permitted one (1) single building sign. Said sign shall be erected as a wall sign and shall not exceed one hundred (100) square feet in sign area. Where a building with three (3) or more tenants faces two (2) or more streets, two such multi-tenant signs shall be authorized provided that each is oriented toward a different street. 2. Projecting signs: (i) Any use other than residential activities may display one (1) projecting sign adjacent to each street, highway, freeway, or off-street parking area on which it has frontage. (ii) Projecting signs may not exceed sixty-five (65) square feet in area. (iii) A use may display both ground and projecting signs if no more than one of these signs is more than twelve (12) square feet in area. (iv) Projecting signs must clear public sidewalks by at least nine (9) feet and may project no more than three (3) feet from a building or one-third (⅓) the width of the sidewalk, if any, whichever is less. Any encroachment greater than three feet shall require an encroachment permit from the department of public works. (v) Projecting signs must be pinned away from the wall at least six (6) inches and must project from the wall at an angle of ninety (90) degrees. (vi) Projecting signs may not extend vertically above the windowsill of a second story. 3. Building signature signs: (i) A wall sign, erected on a building four or more stories in height and actually occupied by a principal occupant shall be considered a building signature sign. For purposes of this section, no part of a parking deck shall be used in calculating the height of a building. (ii) Only one building signature sign shall be allowed on any side elevation of the building and further provided that no building shall contain more than one such sign per side elevation. (iii) Building signature signs are allowed only on buildings four (4) or more stories in height provided no part of such sign shall extend above the top of the building. (iv) The area of a building signature sign shall not exceed five (5) percent of the area of the wall to which it is affixed, and shall not be included in computing the total area of signage imposed for other signs. (v) Building signature signs shall be allowed only for an owner or principal occupant, defined as a building owner or tenant who occupies a minimum of twenty-five (25) percent of the floor space, or one hundred thousand (100,000) square feet of the floor space, of a specific building that is available for occupancy. Any lease for the required amount of floor space is to be for a period of not less than five (5) years. Changes in ownership or occupancy that result in non-compliance with this chapter shall require the removal of the subject sign. (vi) An applicant seeking permission to erect a building signature sign shall provide notarized documentation that it has an ownership interest in the building or that it meets the conditions required to be considered a principal occupant and has permission from the owner to make the application. In determining the level of ownership necessary to qualify as an owner, the city presumes, based on the documentation required to be produced, that the applicant has made such arrangements with other claiming ownership interest as may be necessary to allow the applicant to claim that it may apply for the sign as an owner. 4. Other sign provisions: (i) Internally lit plastic signs are prohibited. (ii) No exposed raceways, ballast boxes, sign cabinets, or electrical transformers shall be permitted. (iii) Sign company names or stamps shall be concealed inside the sign cabinets. Internal sign cabinet illumination is not permitted; instead use ground or building lighting. (iv) Raised or relief letters, logos, graphics, or any other relief shapes may be acceptable solutions to further add dimensions to the sign face. (v) Neon signs will be considered when appropriate to the building design and business function. (vi) Attached banner signs that are a temporary sign of cloth, plastic, paper or similar nonrigid material attached to any structure and anchored on two (2) or more edges or at all four (4) corners are permitted up to a maximum of fifty (50) square feet per structure, in addition to other wall/window/projected signage permitted. (vii) Illustrations on buildings that contain no references to products or services, otherwise known as murals, shall not be considered signs. (viii) All other signs, including, but not limited to monument and portable signs, shall follow section 8-11, signs permitted in commercial and industrial districts. 5. Temporary signage: (i) One construction sign is permitted per commercial project. (ii) The sign may denote the following: project rendering, project logo (if applicable, broker or contractors' logos will not be permitted), project name, tag line of project (if applicable), owner, architect, builder, landscape architect, engineer, financial institution, "For Information", website of project (if applicable, brokers' information will not permitted), phone number, or other pertinent information about the project will be permitted during construction. (iii) The construction sign shall not exceed thirty-two (32) square feet in area. (iv) Permits to be displayed during construction shall be attached to the backside of the construction sign. (v) Additional individual signs for sub-contractors, material suppliers and lending institutions will not be permitted. (vi) Temporary signage will be allowed for new businesses to NBRD properties. Temporary signage will be allowed for a maximum of sixty (60) days from the approval date. Temporary signage should not obstruct views from passing cars. 6. Maintenance of signs: Any signs not meeting the following provisions shall be maintained, repaired, or removed within thirty (30) days after receipt of notification by the zoning inspector or his/her designee: (i) The area around the sign shall be properly maintained and clear of brush, trees and other obstacles around the sign that may obscure the sign face so as to make sign face readily visible. (ii) All inoperable lighting or damaged panels must be repaired or replaced. (iii) All sign copy shall be maintained securely to the face and all missing copy must be replaced. (iv) All signs shall be maintained in a structurally safe condition. (m) Applicability. Where the requirements of this subsection conflict with the requirements, conditions, or permits of other regulatory agencies or utility providers, the zoning administrator may (but shall not be required to) administratively permit a reasonable modification without the necessity of a variance being obtained.

(Ord. No. 2023-010, Exh. A, 2-23-2023)

Ask a question about North Charleston law

Corpus searches the North Charleston sections it holds and shows the ones that match, with their citations. Free, no sign-in.