For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17-3 — Amendments to Code adopted

Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 17-3

Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/93e1f5db-f026-4dfc-bbdb-4751e7da6e4c

Sec. 17-3. - Amendments to Code adopted.

The following provisions of the 2018 International Fire Code are hereby amended as follows and made a part of the City's Fire Code: (1) Sections 109.1, 109.2, and 109.3 are amended by deleting said sections in their entirety and substituting in lieu thereof the following: 109.1 Construction Board of Adjustment and Appeals. The Construction Board of Adjustment and Appeals for all of the adopted building codes of the City of Chattanooga, as established by Chattanooga City Code, Part II, Section 2-625, shall act as the board to hear appeals from any decision of the Fire Marshal or their designee and to consider variances to the Fire Codes as adopted by the City. (2) Section 1103.5.1 is amended by deleting said section in its entirety. (3) Appendix D, Section D103.6.1 is amended by deleting said section in its entirety and substituting in lieu thereof the following: D103.6.1 Roads 22 feet to 26 feet in width. All fire access roads shall be at least 22 feet in width with wider areas for hydrants and designated parking areas which shall be approved by the City Engineer. Designated pulloffs of 8 feet in width shall be approved by the City Engineer on any streets less than 24 feet in width. Fire access roads 22 feet to 26 feet in width shall be posted on both sides as a fire lane. (4) Appendix D, Sections D106 and D107 are amended by deleting said sections in their entirety and substituting in lieu thereof the following: D106- Developments requiring more than one access road. All residential or multiple-family residential developments shall be provided with at least two (2) separate and approved fire access roads that meet the International Fire Code, 2018 Edition D107.2 Remoteness requirement, whenever any development project has more than 199 dwelling units, regardless of whether the dwelling units are equipped with an approved automatic sprinkler system. (5) The City of Chattanooga requires locking FDC caps on all fire department connections (Intake & Discharge) for all water-based fire protection systems. Every new fire department connection for water-based fire protection systems shall be provided with a locking plug or cap of the type approved by the Fire Chief. On all new construction, these caps and/or plugs must be installed before the issuance of a Certificate of Occupancy.

(Ord. No. 11720, § 2, 7-26-05; Ord. No. 12273, § 3, 8-4-09; Ord. No. 12504, § 3, 4-26-11; Ord. No. 12618, § 3, 6-26-12; Ord. No. 13930, § 3, 12-20-22; Ord. No. 13986, § 2, 6-13-23)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.