§ 21-128 — Exterior of structure
Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 21-128
Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/6ae9ec66-6fb0-46ad-81a4-b39d6c12165d
Sec. 21-128. - Exterior of structure.
(a) General. The exterior of a Structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare. (b) Basements and crawl spaces. Every basement and/or crawl space access way shall be so constructed and maintained as to prevent the entrance of rodents, rain and surface drainage water into the structure. Basements and crawl spaces shall be maintained reasonably free from dampness to prevent conditions conducive to decay or deterioration of the structure. (c) Chimneys and towers. All chimneys, cooling towers, smoke stacks and similar appurtenances shall be maintained structurally safe and sound and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. (d) Decorative features. All cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition. (e) Exterior walls. All exterior walls shall be free from holes, breaks, and loose or rotting materials and shall be maintained weatherproof and properly surface coated where required to prevent deterioration. (f) Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. (g) Handrails and guards. Every handrail and Guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. (h) Overhang extensions. All overhang extensions, including, but not limited to, canopies, marquees, signs, metal awnings, fire escapes, standpipes and exhaust ducts, shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. (i) Piers. Piers shall not be leaning or buckling out of plumb from top to bottom more than one-third (⅓) the thickness of the wall. Piers should be free of large cracks that weaken their bearing capacity. Loose or missing masonry units and mortar shall be properly replaced. (j) Premises identification. Structures shall have Approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four (4) inches in height with a minimum stroke width of one-half (0.5) inch. (k) Protective treatment. All exterior surfaces, including, but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences, shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking or chipped paint shall be eliminated, and surfaces repainted. All siding and masonry joints, as well as those between the structure envelope and the perimeter of windows, doors and skylights, shall be maintained weather-resistant and watertight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. (l) Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a nuisance. (m) Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads. (n) Structural members. All structural members shall be maintained free from deterioration and shall be capable of safely supporting the imposed dead and live loads. (o) Structure security. Doors, windows and hatchways for dwelling units, rooming units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within. (1) Doors. Doors providing access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a deadbolt lock designed to be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort and shall have a minimum lock throw of one (1) inch. Such deadbolt locks shall be installed according to the manufacturer's specifications and maintained in good working order. For purposes of this section, a sliding bolt shall not be considered an acceptable deadbolt lock. (2) Windows. Operable windows located in whole or in part within six (6) feet above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a window sash locking device. (3) Basement hatchways. Basement hatchways that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with devices that secure the units from unauthorized entry. (p) Windows, doors and screens. (1) Every window, skylight, exterior door, and basement or cellar door and hatchway shall be substantially watertight and rodent-proof and shall be kept in sound working condition. Window panes or an approved substitute shall be maintained without cracks or holes. The window sash shall be properly fitted and weathertight within the window frame. (2) Every window required for light and Ventilation for habitable rooms shall be capable of being easily opened and secured in any position by the window hardware. Every exterior door shall be provided with proper hardware, be maintained in good condition, and fit reasonably well within its frame so as to substantially exclude rain and wind from entering the structure. All windows and doors shall be provided with acceptable, standard and operable locking devices. (3) Every structure, dwelling unit, rooming unit and housekeeping unit shall have an unobstructed means of egress leading to an open space at ground level. (4) Every dwelling unit shall have screens to effectively cover all openable windows and doors. Every door opening to an outdoor space shall have screens and a self-closing device. Every window opening to an outdoor space, used or intended to be used for ventilation, shall have screens. Structures containing central heating furnaces and air conditioning equipment for mechanical ventilation year-round are not required to have screens. Window-type air conditioning units are not included in this exception. Screens shall be fastened to removable frames and have a mesh with a maximum gauge of fourteen (14) by eighteen (18).
(Ord. No. 13442, § 1, 3-12-19)
Ask a question about Chattanooga law
Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.