Sec. 21-76. - Unsafe structure defined.

For purposes of this chapter, the term "unsafe structure" shall include any of the following: (a) Unsound Structure. An unsound Structure is one that is found to be dangerous to the life, health, property or safety of the public or occupants of the structure because it does not provide minimum safeguards to protect or warn occupants in the event of fire or is so damaged, decayed, dilapidated, structurally unsafe or of such faulty construction or unstable foundation that partial or complete collapse is possible. (b) Unsafe equipment. Unsafe equipment includes any boiler, heating equipment, elevator, moving stairway, electrical wiring or device, flammable liquid containers or other equipment on the premises or within the structure which is in such disrepair or condition that such equipment is a hazard to life, health, property or safety of the occupants of the structure or premises or to the public. (c) Structure unfit for human occupancy. A Structure is unfit for human occupancy when, because of the degree to which it is in disrepair or lacks maintenance, such structure is unsanitary, vermin- or rat-infested, contains filth and contamination, or lacks ventilation, illumination, sanitary or heating facilities, or other essential equipment required by this chapter or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. (d) Unlawful Structure. An unlawful Structure is one found in whole or in part to be occupied by more persons than permitted under this chapter or that was erected, altered or occupied contrary to law. (e) Dangerous Structure or Premises. For the purposes of this chapter, any structure or premises that has any of the conditions or defects described below shall be considered dangerous: (1) Any door, aisle, passageway, stairway, exit or other means of egress that does not conform to the Building Code or the City's fire codes as related to the requirements for existing buildings. (2) The walking surface of any aisle, passageway, stairway, exit or other means of egress is so warped, worn loose, torn or otherwise unsafe as to not provide safe and adequate means of egress. (3) Any portion of a Structure that has been damaged by fire, earthquake, wind, flood, deterioration, neglect, abandonment, vandalism or by any other cause to such an extent that it is likely to partially or completely collapse or to become detached or dislodged. (4) Any portion of a Structure that is not of sufficient strength or stability or is not so anchored, attached or fastened in place so as to be capable of resisting natural or artificial loads of one and one-half (1½) the original designed value. (5) The Structure, because of dilapidation, Deterioration, decay, faulty construction, the removal or movement of some portion of the ground necessary for support or for any other reason, is likely to partially or completely collapse or some portion of the foundation or underpinning of the structure is likely to fail or give way. (6) The Structure is clearly unsafe for its use and occupancy. (7) The Structure is neglected, damaged, dilapidated, unsecured or abandoned so as to become an attractive nuisance to children who might play in the structure to their danger or become a harbor for persons to commit a nuisance or an unlawful act. (8) Any Structure has been constructed, exists or is maintained in violation of any specific requirement or prohibition of the Building Code or the City's fire codes or of any law or ordinance to such an extent as to present either a substantial risk of fire, building collapse or any other threat to life or safety. (9) A Structure, used or intended to be used for dwelling purposes, because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangement, inadequate light, ventilation, mechanical or plumbing system, or otherwise, is determined by the Code Official to be unsanitary, unfit for human habitation or in such a condition that is likely to cause sickness or disease. (10) Any Structure, because of a lack of sufficient or proper fire-resistance-rated construction, fire protection systems, electrical system, fuel connections, mechanical system, plumbing system or other cause, is determined by the Code Official to be a threat to life or health. (11) A Structure, used or intended to be used for dwelling purposes, which does not have an installed kitchen sink in each dwelling unit properly connected to the hot and cold potable water supply pipes and the sewer system. (12) A Structure, used or intended to be used for dwelling purposes, which does not have an installed tub or shower and lavatory properly connected to the water pipes and sewer system. (13) A Structure which does not have a flush-type water closet located in a room affording privacy and properly connected to the water pipes and sewer system. (14) A Structure which does not have installed electric lighting facilities consisting of at least two (2) separate wall type convenience outlets or one (1) ceiling type fixture and one (1) wall type outlet for every habitable room, to be installed in accordance with the City's electrical code. (15) A Structure wherein heat is not furnished from a central heating plant does not have fireproof chimney flues so that habitable rooms can be heated. Heating equipment must be permanently installed, properly vented and maintained in good order and repair. (16) A Structure whose walls or other vertical members list, lean or buckle to such an extent that a plumb line suspended from the top edge of such a member falls outside of a distance of its base equal to one-third (⅓) the thickness of such member. (17) A Structure which, exclusive of the foundation, has support members which have deteriorated to such an extent as to be unable to safely support the applied loads or which have forty (40) percent damage or Deterioration of the non-supporting enclosing or outside walls or covering. (18) A Structure which has improperly distributed loads upon the floors or roofs or in which the same are overloaded or which have insufficient strength to be reasonably safe for the purpose used. (19) A Structure which has parts thereof which are so attached that they may fall and injure persons or property. (20) A Structure which does not have an unobstructed means of egress leading to an open space at ground level. (21) A Structure which does not have the window area for each habitable room equal to at least eight (8) percent of the total floor area of such room. (22) A Structure which does not have Ventilation provided by windows equal to a minimum of forty-five (45) percent of the openable window area size of each room, except where there is supplied some device affording adequate ventilation and approved by the Code Official. (23) Any portion of a Structure remains on a site after the demolition or destruction of the structure or whenever any structure is abandoned so as to constitute an attractive nuisance or hazard to the public.

(Ord. No. 13442, § 1, 3-12-19)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.