For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 38-16 — Residential Zone Dimensional Standards

Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 38-16

Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/5c506a1c-0ae8-4d91-aae5-f770eb4e66bd

Sec. 38-16. - Residential Zone Dimensional Standards

(a) Table 38-16.1: Residential Zone Dimensional Standards establishes the dimensional standards for the residential zones. These regulations apply to all uses within each zone unless a different standard is listed for a specific use. ..... 1. Minimum Suburban Infill Lot Frontage for RN-1-7.5: The minimum frontage and for Suburban Infill Lots shall be determined as follows: ..... Applicability. The Minimum Suburban Infill Lot Frontage Regulations shall apply only to: a. Lots zoned RN-1-7.5. ..... b. Proposed lot frontage is less than one hundred twenty (120) feet. ..... c. Lots fronting an existing public street. ..... d. Lots served by sewers. ..... 2. Exceptions. This rule shall not apply to: ..... a. Planned Unit Developments (PUDs). ..... b. Lots created on a new street. ..... c. The consolidation of lots. ..... d. Lots at the terminus of permanent dead-end streets with thirty-five (35) feet of street frontage or more. ..... e. Lots that are a combination of existing lots where all of the lots are as large or larger than the previous lots and have equal or greater frontage than the previous lots. ..... 3. Compatible Lots. The following properties shall be used to determine the block character for purposes of establishing lot compatibility: ..... a. Lots with on the same and opposing block face within three hundred (300) feet of the boundary of the boundary of the property proposed to be subdivided. ..... b. Lots abutting each quadrant of an intersection when the proposal involves a corner lot; and ..... c. Lots that abut or are directly across a public way, but not to the rear of the property, from the property proposed to be subdivided. ..... 4. Excluded Lots. The following properties shall not be used to determine the block character for purposes of establishing lot compatibility: ..... a. Properties zoned non-residential or multi-family. ..... b. Properties zoned from single-family, but used for legal non-residential uses or other legal non-conforming uses. ..... c. Properties where development continuity cannot be provided due to a natural or man-made barrier, including but not limited to, arterial or collector streets, public land, railroad right-of-way, waterways, or ..... d. Properties that face a block face within a non-residential zoning district. ..... e. Interior lots located to the rear of another lot but with a narrow portion extending to the street when that narrow portion is less than the frontage required by the Chattanooga Zoning Ordinance. ..... 5. Lot Frontage Compatibility Calculation. New residential infill lots shall have a minimum lot frontage that is no smaller than the smallest frontage on the same and opposing block face within three hundred (300) feet of the lot to be subdivided. ..... a. The new infill lot frontage is not required to exceed one hundred twenty (120) feet. ..... b. The new infill lot frontage shall not be less than 60'. ..... c. Each lot frontage shall be the actual access to the property as well as the legal access (e.g. — no sole access via common easement). ..... 6. Applications for variances to the minimum lot frontage compatibility calculation and minimum Suburban Infill front yard setback, shall be made to the Board of Appeals. ..... LOT STANDARDS DIAGRAM [image omitted; see the official code] A = Lot Width Table 38-16.1: Residential Zones Dimensional Standards—Lot Standards RN-1-7.5 | RN-1-6 | RN-1-5 | RN-1-3 | RN-2 | RN-3 Minimum Lot Area | 7,500sf NR: 10,000sf | 6,000sf NR: 10,000sf | 5,000sf NR: 10,000sf | 3,000sf NR: 10,000sf | SU: 5,000sf SU-A: 2,750sf/unit 2U: 5,500sf TH: 1,100sf/unit NR: 10,000sf | SU: 5,000sf SU-A: 2,750sf/unit 2U: 5,500sf 3U, 4U: 6,500sf TH: 1,100sf/unit MU: 950sf/unit NR: 10,000sf Minimum Lot Width | 60' or average of blockface, whichever is less 60' or the Minimum Lot Frontage Required within the Minimum Suburban Infill Lot Frontage Per Section 38-16(a)(1) | 55' or average of blockface, whichever is less NR: 75' | 50' or average of blockface, whichever is less NR: 75' | 25' NR: 75' | SU, 2U: 50' or average of blockface, whichever is less SU-A: 25'/unit TH: 15'/unit NR: 75' | SU, 2U, 3U, 4U: 50' or average of blockface, whichever is less SU-A: 25'/unit TH: 15'/unit MU: 50' NR: 75' Maximum Building Coverage | 60% NR: 50% | 60% NR: 50% | 60% NR: 50% | 60% NR: 50% | 60% (TH is exempt from this standard) NR: 50% | 60% (TH is exempt from this standard) NR: 50% Table 38-16.2: Residential Zones Dimensional Standards—Lot Standards TRN-1 | TRN-2 | TRN-3 | TRN-4 Minimum Lot Area | SU: 5,000sf SU-A: 2,750sf/unit 2U: 5,500sf 3U, 4U: 5,500sf NR: 10,000sf | SU: 5,000sf SU-A: 2,750sf/unit 2U, 3U, 4U: 5,500sf 5U, 6U: 6,500sf TH: 1,100/unit NR: 10,000sf | SU: 3,000sf SU-A: 2,750sf/unit 2U: 4,000sf 3U, 4U: 5,500sf TH: 1,100sf/unit MU: 950sf/unit NR: 10,000sf | TH: 1,100sf/unit MU: 950sf/unit NR: 10,000sf Minimum Lot Width | SU, 2U, 3U, 4U: 40' or average of blockface, whichever is less SU-A: 20'/unit NR: 75ft | SU, 2U, 3U, 4U: 40' or average of blockface, whichever is less SU-A: 20'/unit 5U, 6U: 40'/unit TH: 15'/unit NR: 75' | SU: 25' SU-A: 20'/unit 2U, 3U, 4U: 40' TH: 15'/unit MU: 50' NR: 75' | TH: 15'/unit MU: 50' NR: 75' Maximum Building Coverage | 60% NR: 50% | 60% (TH is exempt from this standard) NR: 50% | 60% (TH is exempt from this standard) NR: 60% | 60% (TH is exempt from this standard) NR: 50% HEIGHT DIAGRAM [image omitted; see the official code] A = Maximum Building Height Table 38-16.3: Residential Zones Dimensional Standards—Height RN-1-7.5 | RN-1-6 | RN-1-5 | RN-1-3 | RN-2 | RN-3 Maximum Building Height1 | 35' | 35' | 35' | 35' | 35' | 35' MU: 65' 1 1 Maximum height of a structure is limited to 35' within 35' of an RN-1-7.5, RN-1-6, RN-1-5, RN-1-3, RN-2, TRN-1, or TRN-2 zone. This limitation applies only to that portion of a structure within the 35' distance. Table 38-16.4: Residential Zones Dimensional Standards—Height TRN-1 | TRN-2 | TRN-3 | TRN-4 Maximum Building Height1 | 35' | 35' | 35' | 35' MU: 50' | MU: 65' 1 1 Maximum height of a structure is limited to 35' within 35' of an RN-1-6, RN-1-5, RN-2, TRN-1, or TRN-2 zone. This limitation applies only to that portion of a structure within the 35' distance. SETBACK STANDARDS DIAGRAM [image omitted; see the official code] A = Front Setback B = Interior Side Setback C = Corner Side Setback D = Rear Setback Table 38-16.5: Residential Zones Dimensional Standards—Setbacks RN-1-7.5 | RN-1-6 | RN-1-5 | RN-1-3 | RN-2 | RN-3 Minimum Front Setback 1 | 25' or average setback (See Sec. 38-10 (l) (2) (iv)), whichever is less | 25' or average setback (38-10 (l) (2) (iv)), whichever is less | 15' or average setback ( See Sec. 38-10 (l) (2) (iv)), whichever is less | 15' or average setback (See Sec. 38-10 (l) (2) (iv)), whichever is less | 15' or average setback (See Sec. 38-10 (l) (2) (iv), whichever is less | 15' or average setback (See Sec. 38-10 (l) (2) (iv)), whichever is less Where adjacent lots are not developed, 25' | Where adjacent lots are not developed, 25' | Where adjacent lots are not developed, 15' | Where adjacent lots are not developed, 15' | Where adjacent lots are not developed, 15' | Where adjacent lots are not developed, 15' From any Interior Public Street: Fifteen (15) feet; ten (10) feet if rear parking and loading is provided | From any Interior Public Street: Fifteen (15) feet; ten (10) feet if rear parking and loading is provided | From any Interior Public Street: Fifteen (15) feet; ten (10) feet if rear parking and loading is provided Minimum Interior Side Setback | 5' | 5' | 5' | 5' | 5' | Structures 40' or less in height: 5' Structures over 40' in height: 10' plus 1' of additional setback for each 2' of building height over 40' Minimum Corner Side Setback | 25' | 15' | Side/Corner: alley 5' Side/Corner: street 10' | Side/Corner: alley 5' Side/Corner: street 10' | 15' | 15' Minimum Rear Setback | 25' | 25' | 25' | 25' | 25' | Structures 40' or less in height: 25' Structures over 40' in height: 35' 1 For purposes of this section, the term "interior street" refers to any street built as part of the development, both sides of which are zoned for the applicable zone. Table 38-16.6: Residential Zones Dimensional Standards—Setbacks TRN-1 | TRN-2 | TRN-3 | TRN-4 Front Setback | Build-To Zone (BTZ): Average setback of adjacent lots plus or minus 5' However, if average setback is more than 15', then 15' plus or minus 5' Where adjacent lots are not developed, 15' plus or minus 5' | Build-To Zone (BTZ): Average setback of adjacent lots plus or minus 5' However, if average setback is more than 15', then 15' plus or minus 5' Where adjacent lots are not developed, 15' plus or minus 5' | Build-To Zone (BTZ): Average setback of adjacent lots plus or minus 5' However, if average setback is more than 15', then 15' plus or minus 5' Where adjacent lots are not developed, 15' plus or minus 5' | Build-To Zone (BTZ): Average setback of adjacent lots plus or minus 5' However, if average setback is more than 15', then 15' plus or minus 5' Where adjacent lots are not developed, 15' plus or minus 5' Minimum Interior Side Setback | 5' | 5' | Structures 40' or less in height: 5' Structures over 40' in height: 8', plus 1' of additional setback for each 2' of building height over 40' | Structures 40' or less in height: 5' Structures over 40' in height: 8', plus 1' of additional setback for each 2' of building height over 40' Minimum Corner Side Setback | 10' | 10' | 10' | 10' Minimum Rear Setback | 10' unless abutting an alley, then 5' | 10' unless abutting an alley, then 5' | Structures 40' or less in height: 5' Structures over 40' in height abutting an alley: 5' Structures over 40' in height not abutting an alley: 15' | Structures 40' or less in height: 5' Structures over 40' in height abutting an alley: 5' Structures over 40' in height not abutting an alley: 15'

(Ord. No. 14137, § 1, 7-23-24; Ord. No. 14138, § 1, 7-23-24; Ord. No. 14169, § 1, 11-19-24; Ord. No. 14181, § 1, 12-17-24; Ord. No. 14202, § 1, 2-18-25; Ord. No. 14238, § 1, 5-20-25; Ord. No. 14253, § 1, 7-15-25)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.