Sec. 38-47. - Exterior Lighting Controls

(a) A. Lighting Plan Required ..... (1) A lighting plan is required for all nonresidential uses, mixed-use, and multi-unit developments. Other developments are exempt from a required lighting plan but are subject to applicable lighting standards of Item B below. ..... (2) A lighting plan must include the following: ..... (i) A plan showing all light pole locations, building-mounted lights, bollard lights, and all other lighting. ..... (ii) Specifications for luminaires, including certifications of energy efficient lighting, and lamp types, and poles, including photographs or drawings of proposed light fixtures. ..... (iii) Pole and luminaire details including pole height, height of building-mounted lights, mounting height, and height of the luminaire. ..... (iv) Elevations of the site including all structures and luminaires sufficient to determine the total cutoff angle of all luminaires and their relationship to abutting parcels. ..... (v) For developments subject to site plan review, photometric plans that show the footcandle measurement at all lot lines may be required if the lot is adjacent to a residential zone. ..... (vi) Other information and data reasonably necessary to evaluate the required lighting plan. ..... (b) Lighting Standards ..... (1) The maximum allowable footcandle at any lot line is one footcandle. ..... (2) All luminaires must be full cutoff luminaire design. ..... (3) The maximum total height of a freestanding luminaire is 20 feet in a nonresidential zone, and 15 feet in a residential zone. ..... (4) All outdoor luminaires must be located and adequately shielded so that there is no glare onto adjacent lots or onto the public right-of-way. Exterior spot lighting or other illumination of non-residential uses or structures shall be directed away from any residential zones or uses. ..... (5) Those uses required to submit a lighting plan, per item A above, are also subject to the following: ..... (i) All public lighting sources must have a correlated color temperature (CCT) at or below 3200ºK. This does not apply to outdoor recreation fields. ..... (c) Exceptions to Lighting Standards ..... (1) Luminaires used for public roadway illumination or installed by a utility to light public rights-of-way are exempt from the requirements of this Code. ..... (2) All temporary emergency lighting required by public safety agencies, other emergency services, or construction are exempt from the requirements of this Code. ..... (3) Shielded, directional accent lighting, or uplighting is permitted but must be aimed at a building facade, sign, or accent feature, such as landscape, and directed so that glare is not visible from adjacent properties. However, such lighting must not exceed one footcandle at any lot line. ..... (4) Security lighting installed with a motion vacancy sensor, which extinguishes the lights within 15 minutes after the area is vacated. ..... (5) Because of their unique requirements for nighttime visibility and limited hours of operation, outdoor recreational fields (public or private) such as, but not limited to, football fields, soccer fields, baseball fields, softball fields, tennis courts, driving ranges, and other similar uses are exempt from the lighting standards of Item B above and subject to the following: ..... (i) Recreational fields are permitted a total luminaire height of 65 feet in any zone. Luminaires greater than 65 feet in total height may only be approved by conditional use. ..... (ii) All lighting must be directed onto the field. ..... (iii) Lighting outside the recreational field, such as for parking areas, must comply with the lighting standards of Item B above ..... (iv) The recreational field lighting must be extinguished one hour following the end of the event. Lighting outside the recreational field, such as for parking areas, is not subject to this timeframe in order to facilitate patrons leaving the facility, cleanup, nighttime maintenance, and other closing activities. ..... (6) Temporary holiday and seasonal lighting designs are exempt from the requirements of this Code. ..... (7) Certain temporary uses may use lighting that does not meet the requirements of this section. When such temporary uses are allowed, approval of the lighting plan is required as part of the temporary use permit. ..... (d) Prohibited Lighting ..... (1) Flickering or flashing lights, except that this does not include decorative gas lamps. ..... (2) Searchlights, laser source lights, or any similar high intensity. ..... (3) The use of neon or LED lighting to outline doors, windows, architectural features, and building facades. This does not apply to uplighting of architectural features and building facades as permitted above. ..... (4) Any light fixture that can be confused with or construed as a traffic control device. .....

(Ord. No. 14137, § 1, 7-23-24; Ord. No. 14138, § 1, 7-23-24)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.