§ 12-1002 — Amendments to the 2024 edition of the International Residential Code
Municipal Code of the City of Franklin, Tennessee (Codified through Ordinance No. 2026-13, adopted June 23, 2026 (Supp. No. 30)) · Franklin Municipal Code § 12-1002
Corpus is an independent public-information project, not the official City of Franklin website. Stable reference: corpuslaw.us/code/2c176a89-1125-4696-b229-81ad6a458073
Sec. 12-1002. - Amendments to the 2024 edition of the International Residential Code.
(1) Section R105.2(1) and (5), Work exempt from permit, are amended to read as follows and included in the list of types of work that are exempt from the requirement to obtain a building permit: Section R105.2 (1) Building: One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 200 square feet. Permits for accessory structures, shall be required in accordance with the City of Franklin Zoning Ordinance. Section R105.2 (5) Building: Sidewalks and driveways located entirely on private property. Permits for sidewalks and driveways shall be required in accordance with the City of Franklin Zoning Ordinance. (2) Section 112 Board of Appeals is deleted and in its place is approved to read as follows: Section 112 Means of Appeal. Appeals of decisions of the Building Official (or his designee) made under the International Residential Code shall be heard by the Building and Streets Standards Board of Appeals established in Title 12, Chapter 12 of the Municipal Code. (3) Section R309, Automatic Fire Sprinkler Systems of the International Residential Code, 2024 Edition, is deleted in lieu of the automatic fire sprinkler system requirements found in Title 7, Section 232 of the City of Franklin Municipal Code. (4) Except as provided all foundation walls are to be installed on concrete footings. The Building Official may authorize the use of pre-engineered concrete foundation systems as recognized in Section R402.3 of the International Residential Code to be installed without a continuous concrete footing conditioned upon: i. The permit applicant submitting a foundation plan and load calculations, signed and sealed by a currently licensed State of Tennessee Structural Engineer in conjunction with the building permit application, and ii. A soils report prepared by a certified State of Tennessee geotechnical engineer, shall be provided to the inspector, on-site, prior to the placement of the required stone base, and iii. At the discretion of the Building Official, an as-built survey to verify the location and height of the foundation walls prior to above ground construction commencing, and iv. Compliance with all other applicable City of Franklin adopted building codes, amendments, and ordinances. (5) The text of Table 403.1 is deleted and replaced with the following: Footings, which support a single story structure, shall have minimum dimensions of eight (8) inches thickness and 16 inches width. Footings, which support 2-story structures, shall have minimum dimensions of 10 inches thickness and 20 inches width. Footings, which support more than two stories, shall have minimum dimensions of 12 inches thickness and 24 inches width. Footings are to be continuous with a minimum of two (2) courses of ½-inch or greater reinforcing steel installed. Some site conditions may necessitate footings to be engineered. (6) The first sentence of Section R406.1 is amended to delete the words "and enclose habitable or usable spaces below grade" so that the sentence reads: Except where required to be waterproofed by Section R406.2, foundation walls that retain earth shall be damp-proofed from the top of the footing to the finished grade. (7) The first sentence of Section R406.2 is amended to delete the words "and enclose habitable or usable spaces located below grade" so that the sentence reads: In areas where a high water table or other severe soil-water conditions are known to exist, exterior foundation walls that retain earth shall be waterproofed with a membrane extending from the top of the footing to the finished grade. (8) Section R406.3 is deleted in its entirety and replaced with the following: Wood foundations located below grade are not permitted within the City of Franklin. (9) The text of Section R407 is deleted in its entirety and replaced with the following: No foundation columns made of wood shall be used in crawl spaces where use of concrete masonry blocks or similar material can be used in compliance with the applicable code. In situations where such concrete masonry blocks or similar material cannot accomplish this according to code, columns must be designed by an engineer before installation. When a designed alternative column is used, protection from possible moisture or other conditions causing deterioration will be necessary. Steel pipe, of adequate size and loading capacity, may be used as interior crawl space columns when pier footings are elevated at least two inches above final grade of crawl space area. Such pipes shall be anchored top and bottom and shall be painted with a rust-resistant paint. (10) At least one positive drain is required in every crawl-space foundation upon which a structure is to be constructed. Positive drains shall be installed in such a manner to drain all water that may accumulate. Crawl space grading shall be accomplished prior to any construction beginning on the foundation. Such grading shall be consistent in grade that will drain any possible water from all areas of the crawl space. No pockets or trenches will be allowed to collect water. Natural soils shall be required to achieve proper grade to the positive drain. (11) Chapter 11 of the International Residential Code is deleted in its entirety. The energy code for one- and two-family dwellings shall be the currently adopted International Energy Conservation Code. (12) Section R408.3 Unvented Crawl Space is amended to read as follows: Ventilation openings in under-floor spaces specified in Sections R408.1 and R408.2 shall not be required where exposed earth is covered with a continuous Class I vapor retarder. Joints of the vapor retarder shall overlap by 6 inches (152 mm) and shall be sealed or taped. The edges of the vapor retarder shall extend at least 6 inches (152 mm) up the stem wall and shall be attached and sealed to the stem wall or insulation.
(1976 Code, § 4-1002; Ord. No. 2000-62, 1- -2001, Ord. No. 2004-49, 5- -2004; Ord. No. 2005-46, 6- -2005; Ord. No. 2007-28, § I, 4-10-2007; Ord. No. 2007-81, § I, 7-10-2007; Ord. No. 2010-25, § II, 5-25-2010; Ord. No. 2010-69, § VIII, 11-23-2010; Ord. No. 2013-52, § II, 1-14-2014; Ord. No. 2015-18, § I, 9-22-2015; Ord. No. 2025-40, § II, 10-14-2025)
Ask a question about Franklin law
Corpus searches the Franklin sections it holds and shows the ones that match, with their citations. Free, no sign-in.