§ 18-211 — Use of public sewers
Municipal Code of the City of Franklin, Tennessee (Codified through Ordinance No. 2026-13, adopted June 23, 2026 (Supp. No. 30)) · Franklin Municipal Code § 18-211
Corpus is an independent public-information project, not the official City of Franklin website. Stable reference: corpuslaw.us/code/c295bf00-47e8-490b-9861-7164a64bc4b5
Sec. 18-211. - Use of public sewers.
(1) No stormwater, groundwater, rainwater, street drainage, rooftop drainage, basement drainage, subsurface drainage, foundation drainage, yard drainage, swimming pool drainage, process water drainage, cooling water, or other unpolluted or minimally polluted water shall be discharged into the city's sewer system unless no other reasonable alternative is available, except with permission from the director. Reasonable conditions shall be prescribed, and a sewer service charge will be issued based upon the quantity of water discharged as measured by a flowmeter or a reasonable estimate accepted by the director. All users shall be required to maintain their private sewer lines to prevent filtration of groundwater or stormwater as a condition of use of the system and shall immediately replace or repair any leaking or damaged lines. (2) The POTW will accept discharge of contaminated stormwater if the following criteria are met: (a) All known and available technology will not prevent contamination or treat contaminated water to meet state standards for discharge to receiving waters or will cause unreasonable financial burden; (b) The contaminated stormwater meets the POTW's discharge limits and all state and federal pretreatment requirements; and (c) The volume of discharge will not exceed the hydraulic loading in the collection system or the treatment plant. (3) Adequate and proper pretreatment facilities, including grease traps, must be provided for other than domestic wastewater discharges when such wastewater exceeds the limits of pollutants established in this chapter of the Franklin Municipal Code. The pretreatment facilities must be installed in accordance with plans approved by the director and shall be properly operated by the user. Such pretreatment facilities shall be provided as a condition on the permit for connection to the POTW and may be required on new or existing connections where conditions warrant as determined by the director. The facilities shall always be subject to inspection by the director or his authorized representative. In the event facilities are determined to be inadequate or improperly operated, the user shall be given written notice of the deficiency and shall correct such deficiency. (a) All food service establishments, including but not limited to cafes, restaurants, hotels, retirement centers, nursing homes, hospitals, grocery stores, markets, prisons, mobile food units, or other food preparation establishments, are required to comply with the City of Franklin Fats, Oils and Grease (FOG) Management Policy. The grease interceptor must be designed in accordance with the City of Franklin standards, shall be easily accessible for cleaning, have all proper components, and be approved by the City of Franklin. Failure to meet the requirements of the FOG management policy will result in enforcement action, which may include fines, penalties and compliance schedule requirements. (4) Prohibited discharge standards. (a) General prohibitions. No user shall introduce or cause to be introduced into the POTW any pollutant or wastewater which causes pass through or interference. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. (b) Specific prohibitions. No user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater: (1) Any wastewater having a temperature which will inhibit biological activity in the POTW treatment plant resulting in interference, but in no case wastewater with a temperature at the introduction into the POTW treatment plant which exceeds 104 degrees Fahrenheit (40° C); (2) Unless a higher discharge temperature is specified in the user's wastewater discharge permit, no user shall discharge into a sewer line or other appurtenances of the POTW wastewater with a temperature exceeding 150 degrees Fahrenheit, or cause a violation of the specific prohibition in [subsection] (b) of this section; (3) Pollutants which create a fire or explosion hazard in the POTW including, but not limited to, pollutants with a closed-cup flashpoint of less than 140 degrees Fahrenheit (60 degrees centigrade) as determined by a Pensky-Martens closed-cup tester, using the test method specified in the American Society for Testing and Materials (ASTM) D-93-79 or D-93-80k, or a Setaflash closed-cup tester, using the test method specified in ASTM D-3278-78, or pollutants which cause an exceedance of ten percent of the lower explosive limit (LEL) at any point within the POTW; (4) No waste from garbage disposals shall be discharged into the POTW's sewers except from private garbage disposals used in an individual residence or upon permit issued by the director for preparation of food consumed on premises, and then only when applicable fees are paid. It shall be unlawful for any person to use a garbage disposal grinder connected to the sewer system for the purpose of grinding and discharging plastic, paper products, inert materials, or anything other than the waste products from normal food preparation and consumption; (5) Solid or viscous substances, including but not limited to fats, oils and grease, ashes, cinders, sand, mud, straw, shavings, metal, glass, rags, feathers, tar, plastics, wood, manure, wipes, hair, or any substance capable of causing obstruction to the flow in sewers, capable of coating the sewers or other appurtenances, or causing other interferences with the proper operation of the POTW; (6) Any water or waste having a pH lower than 6.0 or higher than 9.0 or having any other corrosive property capable of causing damage or hazard to structures, equipment, and personnel of the POTW; (7) Any water and waste containing a toxic or poisonous substance in amounts exceeding standards established by the Environmental Protection Agency pursuant to section 307(a) (b) or (c) of the Act; (8) Any radioactive wastes or isotopes of such half-life or concentration that they do not comply with regulations or orders issued by the appropriate authority having control over their use or which may be hazardous to plant facilities or personnel; (9) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; (10) Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin, in amounts that will cause interference or pass through; (11) Any trucked or hauled pollutants, except at discharge points specified by the POTW; (12) Pollutants, including oxygen-demanding pollutants (cBOD 5 , etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause interference with the collection system, pump stations, and the POTW; (13) Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail toxicity tests; (14) Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts color to the treatment plant's effluent, thereby violating the city's NPDES permit; (15) Detergents, surface-active agents, or other substances which that might cause excessive foaming in the POTW; (16) Sludges, screenings, or other residues from the pretreatment of industrial wastes; (17) Any nondomestic user waste known or suspected of being infectious, without first undergoing pretreatment. Pollutants, substances, or wastewater prohibited by this section shall not be processed or stored in such a manner that they could be discharged to the POTW. (5) Regulated wastewater. (a) Wastes having any of the following characteristics may be accepted only under such conditions and/or limitations as may be approved on a case-by-case basis by the director. (1) Any waters or wastes containing constituents in excess of the following concentrations: cBOD 5 | 300 mg/l COD | 600 mg/l TKN | 60 mg/l NH 3 -N | 30 mg/l TSS | 300 mg/l Oil and Grease | 100 mg/l Total Phosphorus | 30 mg/l (2) Intermittent slugs, or short-time high volume discharges, at such discharge rates or concentrations as to overload either the public sewers or the treatment facilities. (3) Any waters or wastes having noxious or malodorous substances which either alone or in combination with other substances which may be present in the wastewater may cause an offensive odor or public nuisance. (4) Any waters or wastes having color which is not removed by the treatment processes or which could adversely affect plant appearance or performance. (b) Restrictions on wastewater strength. No residential, commercial, or industrial user shall discharge wastewater which exceeds the set of standards established in the Industrial User Local Limits and Plant Protection Criteria Evaluation (Appendix I, Table A - Franklin, TN Industrial User Limits Summary) unless an exception is permitted as provided for in this chapter or the user's wastewater discharge permit provides a special permit condition temporarily allowing a higher concentration level in conjunction with a requirement that the user construct a pretreatment facility or institute changes in operation and maintenance procedures to reduce the concentration of pollutants to levels not exceeding the standards set forth in the table within a predetermined time frame (compliance schedule). In addition, all users must meet the City of Franklin organic compound prohibition provided in Appendix I, Table A of the Industrial User Local Limits and Plant Protection Criteria Evaluation. (c) Criteria to protect the POTW influent. The POTW shall monitor the treatment plant influent for each pollutant in the following table. In the event the influent at the POTW reaches or exceeds the levels set forth in this table, the director shall initiate technical studies to determine the cause of the exceedance and shall recommend to the city the necessary remedial measures. The director may also recommend changes to these criteria in the event that the POTW effluent standards are changed, there are changes in applicable laws or regulations, or changes are needed for more effective operation of the POTW. Plant protection criteria have been established for the POTW influent and are listed in Appendix I, Table B of the Industrial User Local Limits and Plant Protection Criteria Evaluation. (d) Hearings. Any regulated discharger may request and receive a hearing before the committee in regard to establishment of discharge conditions or violations thereof and may appeal an adverse decision for hearing by the board. The ruling of the board shall be final. (e) The director may develop best management practices (BMPS), by ordinance or in individual wastewater discharge permits to implement local limits and the requirements of section 18-211(4). (6) Grease, oil and sand interceptors. (a) Disposal of oil by discharge to the sewer system is not permitted. Oils include automotive lubrication oils, transmission and brake fluid, other industrial oils, and vegetable oils used in a restaurant or food preparation or processing facility. (b) Grease, oil, and sand interceptors shall be provided when, in the opinion of the director, they are necessary for the proper handling of liquid wastes containing grease in excessive amounts, or any flammable wastes, sand, and other harmful ingredients. All food service establishments, including but not limited to cafes, restaurants, hotels, retirement centers, assisted living facilities, nursing homes, hospitals, grocery stores, markets, prisons, mobile food units, or other food preparation establishments, are required to comply with the FOG management policy. All interceptors shall be of a type and capacity approved by the director and shall be located as to be readily accessible for cleaning and inspection. Grease and oil interceptors shall be constructed of impervious materials capable of withstanding abrupt and extreme changes in temperature. They shall be of substantial construction, watertight and equipped with easily removable covers which, when bolted in place, shall be gas-tight and watertight. (c) Where installed, all grease, oil, and sand interceptors shall be maintained by the owner, at his expense, in continuously efficient operation at all times. (d) Grease, oil, and sand interceptors shall be subject to monitoring, entry, inspection, reinspection, reinspection fees, reporting and other requirements as determined by the director. (7) Regulation of commercial septic and drain cleaning services. (a) No person shall clean out, drain, or flush any septic tank or any other type of wastewater or excreta disposal system, unless such person, firm, association, or corporation obtains a permit from the director to perform such acts or services. Any person desiring a permit to perform such services shall file an application on the prescribed form. Upon any such application, said permit shall be issued by the water management department when the conditions of this chapter have been met and providing the director is satisfied the applicant has adequate and proper equipment to perform the services contemplated in a safe and competent manner. (b) For each permit issued under the provisions of this section, an annual fee, as established by the board, shall be paid to the city. Any such permit granted shall be for one full fiscal year or fraction of the fiscal year and shall continue in full force and effect from the time issued until the ending of the fiscal year unless sooner revoked and shall be nontransferable. The number of the permit granted hereunder shall be plainly painted on each side of each motor vehicle used in the conduct of the business permitted hereunder. (c) The director shall designate approved locations for the emptying and cleansing of all equipment used in the performance of the services rendered under the permit herein provided for, and it shall be a violation hereof for any such person to empty or clean such equipment at any place other than a place so designated. (d) Failure to comply with all the provisions of this section shall be sufficient cause for the revocation of such permit and for application of penalties described elsewhere in this section. The possession within the service area by any person of any motor vehicle equipped with a body type and accessories of a nature and design capable of serving as a cleaning unit for septic tank or other wastewater or excreta disposal system shall be prima facie evidence that such person is engaged in the business of cleaning, draining, or flushing septic tanks or other wastewater or excreta disposal systems within the service area of the city. (8) Industrial users. (a) Permits. (1) Each industrial user proposing to discharge to the sanitary sewers wastes of any description, exclusive of domestic sewerage shall file with the director an application for the discharge of such wastes. Applications shall be filed on forms provided by the director and shall include data on the raw materials used, finished products, process descriptions, chemicals used and stored, sources of process wastes proposed for discharge to sanitary sewers, approximate number of employees, anticipated water consumption and proposed pretreatment. The application shall further include a list of any environmental permits held by or for the facility, the SIC number(s) of the applicant; wastewater volume; daily, monthly, seasonal and flow peaks as deemed necessary; a description of all toxic materials handled on the premises, including concentrations; site plans; flow plans; mechanical and plumbing plans and details showing all sewers and appurtenances by size, location and elevation; a description of existing and proposed pretreatment and/or equalization facilities; and any other information deemed necessary by the director. (2) The director will provide prompt written acknowledgement of the application and will either approve or reject the request to discharge, or when necessary, request more data. If the application is approved, the director will issue a discharge permit setting forth the conditions under which the wastes may be discharged to the sewers. (3) The wastewater discharge permits shall be expressly subject to all provisions of this chapter and all other applicable regulations, user charges and fees established by the City of Franklin. The permits may contain the following: (i) The units charge or schedule of user charges and fees for the wastewater to be discharged to a public sewer. (ii) Effluent limits, including best management practices, based on applicable pretreatment standards. This includes limits on the average and maximum wastewater constituents and characteristics. (iii) Limits on average and maximum rate at time of discharge or requirements for equalization. (iv) Requirements for installation and maintenance of inspection and sampling facilities. (v) Specifications for monitoring program which may include sampling locations, frequency of sampling, number, types, and standard for testing and reporting schedule. (vi) Compliance schedules. (vii) All technical reports, compliance reports, monitoring reports, or discharge reports shall comply with all signatory requirements of section 18-211(23)(3) and 40 CFR 403.12. (viii) Self-monitoring, sampling, reporting, notification, and record-keeping requirements. These requirements shall include an identification of pollutants (or best management practice) to be monitored, sampling location, sampling frequency, and sample type based on federal, state, and local law. (ix) Requirements for notification of the city of any new introduction of wastewater constituents, any changes affecting potential to have a slug discharge, or any substantial change in the volume or character of the wastewater constituents being introduced into the wastewater treatment system. (x) Requirements to control slug discharge, if determined by the director to be necessary. (xi) Any other conditions as deemed appropriate by the director to ensure compliance with this chapter. (xii) A statement that indicates the wastewater discharge permit issuance date, expiration date and effective date; (xiii) A statement that the wastewater discharge permit is nontransferable without prior notification to the city in accordance with this chapter, and provisions for furnishing the new owner or operator with a copy of the existing wastewater discharge permit; (xiv) A statement of applicable civil and criminal penalties for violation of pretreatment standards and requirements, and any applicable compliance schedule. Such schedule may not extend the time for compliance beyond that required by applicable federal, state, or local law. (xv) Other conditions as deemed appropriate by the director to ensure compliance with this chapter, and state and federal laws, rules, and regulations. (4) The director may request updated information or additional data from any industrial user at any time and failure to respond in a timely manner shall constitute a violation of the discharge permit conditions. (5) It shall be the responsibility of the industrial user to file new or updated data with the director whenever there is a significant change in process waste discharge because of a plant expansion, change in manufacturing process, or any other reason. Upon request by the director, the industrial user shall also provide a comprehensive analysis of the waste stream performed by a qualified commercial laboratory. (6) The application for permit to discharge process wastes to the sanitary sewer and the resulting approval notice setting forth discharge conditions shall not be transferable. A separate application must be filed whenever an industry moves to a new location or is replaced by another industry at the same location. (7) The permit shall be issued for a specified time period, not to exceed five years. A permit may be issued for a period less than a year or may be set to expire on a specific date. The user shall apply for permit reissuance a minimum of 180 days prior to the expiration of the user's existing permit. (8) Any permit issued under the provisions of this chapter is subject to being modified, suspended, or revoked in whole or in part during its term for cause including, but not limited to, the following: (i) Violation of any terms or conditions of the wastewater discharge permit or other applicable federal, state, or local law or regulation. (ii) Obtaining a permit by misrepresentation or failure to disclose fully all relevant facts. (iii) A change in any condition that requires either a temporary or permanent reduction or elimination of the permitted discharge. (iv) Intentional failure of a user to accurately report the discharge constituents and characteristics or to report significant changes in plant operations or wastewater characteristics. (9) Monitoring manholes. Any industrial user discharging industrial process wastes of any description shall install a suitable monitoring manhole in the building sewer to facilitate observation, sampling and measurement of the wastes. Such manhole, when required, shall be suitably located, and shall be constructed in accordance with plans approved by the director. The manhole shall be installed by the owner at his expense and shall be maintained by him so as to be safe and accessible at all times. (10) Surveillance fees. Any industrial user discharging industrial process wastes of any description shall be charged a surveillance fee as recommended by the director to compensate the city for the added cost of collecting and analyzing waste samples on a periodic basis to ensure compliance with the terms of this chapter. Results of such analyses will be furnished to the industrial user. The surveillance fee shall be levied in addition to all other applicable charges, user's fee and/or taxes, and shall be subject to adjustment on an annual basis. (11) Monitoring and right of entry. (a) Monitoring equipment. Automatic composite samplers and monitoring units will be installed at the monitoring manholes of industrial dischargers when and as deemed necessary by the director. (b) Right of entry, monitoring requirements. The director or his designee shall have the right to enter the premises of any user to determine whether the user is complying with all requirements of this chapter and any individual wastewater discharge permit or order issued hereunder. Users shall allow the director ready access to all parts of the premises for the purposes of inspection, sampling, records examination and copying, and the performance of any additional duties. (1) Where a user has security measures in force which require proper identification and clearance before entry into its premises, the user shall make necessary arrangements with its security guards so that, upon presentation of suitable identification, the director shall be permitted to enter without delay for the purposes of performing specific responsibilities. (2) The director shall have the right to set up on the user's property, or require installation of, such devices as are necessary to conduct sampling and/or metering of the user's operations. (3) The director may require the user to install monitoring equipment as necessary. The facility's sampling and monitoring equipment shall always be maintained in a safe and proper operating condition by the user at its own expense. All devices used to measure wastewater flow and quality shall be calibrated at least annually, or as determined in the user's permit, to ensure their accuracy. (4) Any temporary or permanent obstruction to safe and easy access to the facility to be inspected shall not be replaced. The costs of clearing such access shall be born by the user. (5) Unreasonable delays in allowing the director access to the user's premises shall be a violation of this chapter. (12) Surcharges. (a) Any waters or wastes containing constituents in excess of the following concentrations: cBOD 5 | 300 mg/l COD | 600 mg/l TKN | 60 mg/l NH 3 -N | 30 mg/l TSS | 300 mg/l Oil and Grease | 100 mg/l Total Phosphorus | 30 mg/l may be accepted in the public sewer subject to a surcharge to cover the additional cost of treating such wastes. Discharges of extra strength wastes must apply for and operate under a permit from the city. The surcharges will be based on the average of six composite samples collected over a three-month period, at least one of which should have been collected within 30 days of billing date. The director will use independent sampling, split samples, or other means to verify the constituents of the wastewater. (b) The surcharge shall be based on the average concentration and the metered water consumption (or wastewater flows). (c) The surcharge will be calculated according to the following formula with no credit for concentrations less than the threshold concentration amounts listed in paragraph (a) above and with the total applied to the monthly bill of affected users: [A(E-300) + B(F-300) + C(G-30) + D(H-100) + J(I-60) + M(L-30)] x 0.00834 x N x P = SURCHARGE MONTHLY BILL and where: A is the surcharge rate for cBOD 5 of $0.35 per pound; B is the surcharge rate for TSS of $0.35 per pound; C is the surcharge rate for ammonia of $1.75 per pound; D is the surcharge rate for oil and grease of $1.05 per pound; E is the user's effluent cBOD 5 concentration (mg/l); F is the user's effluent TSS concentration (mg/l); G is the user's effluent ammonia concentration (mg/l); H is the user's effluent oil and grease concentration (mg/l); I is the user's effluent TKN concentration (mg/L); J is the surcharge rate for TKN of $1.75 per pound; L is the user's effluent total phosphorus concentration (mg/L); M is the surcharge rate for total phosphorus of $1.75 per pound; N is the user's flow to the sewer system in 1,000 gallons per day; P is the number of days in the billing month; COD may be used in lieu of BOD 5 with the agreement of the director. The COD surcharge rate is $0.15 per pound. (13) Violations. If any discharge to the wastewater system, or any proposed discharge to the system is responsible for or is likely to be responsible for violation of § 18-211(3), (4) hereinabove, and (5), the director may take any action necessary to: (a) Prohibit the discharge of such wastewater. (b) Require a discharger to demonstrate that in-plant modifications will reduce or eliminate the discharge of such substances not in conformity with this chapter. (c) Require pretreatment, including storage facilities or flow equalization necessary to reduce or eliminate the objectionable characteristics or substances so that the discharge will not violate these rules and regulations. (d) Take such other remedial action enforcement action, or penalty action as may be deemed to be desirable or necessary to achieve the purpose of this chapter. (e) In the event any actual or threatened discharge to the wastewater system presents an imminent danger to the health and welfare of persons, the director may take immediate action, such as severance of the sewer connection, to halt or prevent the discharge. (14) Prior approval for pretreatment. Where pretreatment or equalization of wastewater flows prior to discharge into any part of the wastewater treatment system is required, plans, specifications and other pertinent data or information relating to such pretreatment or flow-control facilities shall first be submitted to the director for review and approval. Such approval shall not exempt the discharge of such facilities from compliance with any applicable code, ordinance, rule, regulation or order of any governmental authority. Any subsequent alterations or additions to such pretreatment or flow-control facilities shall not be made without due notice to and prior approval of the director. (15) Maintenance of pretreatment facilities. Where preliminary treatment facilities are provided for any water or waste, they shall be maintained continuously in satisfactory and effective operation by the owner at his expense. (16) Slug discharge control plans. (a) Each SIU shall have an accidental discharge/slug discharge control plan or other action to control slug discharges. Each user must develop, submit for approval, and implement such a plan or take such other action that may be necessary to control slug discharges. Alternatively, the director may develop such a plan for any user. An accidental discharge/slug discharge control plan shall address, at a minimum, the following: (1) Description of discharge practices, including nonroutine batch discharges; (2) Description of stored chemicals; (3) Procedures for immediately notifying [the superintendent] of any accidental or slug discharge, as required by this chapter; and (4) Procedures to prevent adverse impact from any accidental or slug discharge. Such procedures include, but are not limited to, inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site runoff, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants, including solvents, and/or measures and equipment for emergency response. Each user shall provide protection from slug discharges of restricted materials or other substances regulated by this chapter. A discharge of slug load is defined as any discharge at a flow rate or concentration, which could cause a violation of the prohibited discharge standards in section 18-211(4) and (5) of this chapter. A slug discharge is any discharge of a non-routine, episodic nature, including but not limited to an accidental spill or a non-customary batch discharge, which has a reasonable potential to cause interference or pass through, or in any other way violate the POTW's regulations, local limits or permit conditions. No user shall be permitted to discharge into the system until the need for slug control plans or procedures has been reviewed by the director. (b) Users shall be required to prepare spill response plans showing facilities and procedures for providing this protection. These plans shall be submitted to the director for review and approval. All users required to have such a plan shall submit it within 60 days of notification by the director and complete implementation within 90 days of notification. (c) In the case of a slug discharge, accidental discharge, discharges of a nonroutine, episodic nature, or a noncustomary batch discharge, it is the responsibility of the user to immediately notify the POTW of the incident by telephone or in person. Information concerning the location of the discharge, type of waste, concentration and volume, and corrective action shall be provided by the user. Within five days following a slug discharge, the user shall submit a detailed written report describing the cause of the discharge and the measures being taken by the user to prevent future occurrences. Such notification shall not relieve the user of any expense, loss, damage, or other liability which might be incurred as a result of damage to the POTW, fish kills, or any other damage to persons or property, nor shall notification relieve the user of any fines, civil penalties, or other liability which may be imposed by this chapter or other applicable law. (d) A notice shall be permanently posted on the user's premises advising employees of a contact to call in the event of a slug discharge. The user shall ensure that all employees who may cause or allow such slug discharge to occur are advised of the proper emergency notification procedure. (17) Sampling and analysis. (a) Samples collected to satisfy reporting requirements must be based on data obtained through appropriate sampling and analysis performed during the period covered by the report, based on data that is representative of conditions occurring during the reporting period. All collected samples must be of such nature that they provide a true and accurate representation of the industry's effluent quality. (b) Except as indicated in subsection (c) and (d) below, the user must collect wastewater samples using 24-hour flow-proportional composite sampling techniques, unless time-proportional composite sampling or grab sampling is authorized by the director. Where time-proportional composite sampling or grab sampling is authorized by the city, the samples must be representative of the discharge. Also, grab samples may be required to show compliance with instantaneous limits. (c) Samples for oil and grease, dissolved oxygen, temperature, pH, cyanide, total phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques. (d) For sampling required in support of baseline monitoring and 90-day compliance reports required in section 18-211(23) [Tennessee Rule 0400-40-14-.12(2) and (4)], a minimum of four grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the director may authorize a lower minimum. For the reports required by section 18-211(23)(2) (Tennessee Rule 0400-40-14-.12(5) and (8)), the industrial user is required to collect the number of grab samples necessary to assess and assure compliance by with applicable pretreatment standards and requirements. (e) Chain-of-custody procedures, sample preservation techniques, laboratory analysis, and sample holding times required by 40 CFR Part 136 shall be followed in all self-monitoring activities. (f) Monitoring shall be performed at the approved monitoring station on the effluent sewer. All samples collected at the approved monitoring station and analyzed by approved 40 CFR Part 136 methods must be reported to the city. Location and design of the monitoring station shall be subject to the review and approval of the director. Any change in monitoring location will be subject to the approval of the director. (g) All pollutant analyses, including sampling techniques, to be submitted as part of a wastewater discharge permit application or report shall be performed in accordance with the techniques prescribed in 40 CFR Part 136 and amendments thereto, unless otherwise specified in an applicable categorical pretreatment standard. If 40 CFR Part 136 does not contain sampling or analytical techniques for the pollutant in question, or where the EPA determines that the Part 136 sampling and analytical techniques are inappropriate for the pollutant in question, sampling and analyses shall be performed by using validated analytical methods or any other applicable sampling and analytical procedures, including procedures suggested by the director or other parties approved by EPA. (h) If sampling performed by a user indicates a violation, the user must notify the director within 24 hours of becoming aware of the violation. The user shall also repeat the sampling and analysis and submit the results of the repeat analysis to the director within 30 days after becoming aware of the violation. Resampling by the industrial user is not required if the city performs sampling at the user's facility at least once a month, or if the city performs sampling at the user between the time when the initial sampling was conducted and the time when the user or the city receives the results of this sampling, or if the city has performed the sampling and analysis in lieu of the industrial user. (18) Compliance with federal requirements. (a) Any user of the public sewer who discharges industrial waste or matter must satisfy and meet federal government guidelines for pretreatment as may be prescribed from time to time by the Environmental Protection Agency or its successor agency and the guidelines for pretreatment as may be prescribed from time to time by the Division of Water Resources of the Tennessee Department of Environment and Conservation, and further must furnish at its own expense any additional monitoring equipment as reasonably may be necessary in the opinion of the director. (b) Upon the promulgation of the federal categorical pretreatment standards for a particular industrial subcategory, the federal standard, if more stringent than limitations imposed under this chapter for sources in that subcategory, shall immediately supersede the limitations under this chapter. The director shall notify all affected users of the applicable reporting requirements under 40 CFR, Section 403.12. (19) Records. (a) All users, including all categorical industrial users, subject to the reporting requirements of this chapter shall retain, and make available for inspection and copying, all records of information obtained pursuant to any monitoring activities required by this chapter, any additional records of information obtained pursuant to monitoring activities undertaken by the user independent of such requirements, and documentation associated with best management practices established under section 18-211(5)(e). Records shall include the date, exact place, method, and time of sampling, and the name of the person(s) taking the samples; the dates analyses were performed; who performed the analyses; the analytical techniques or methods used; and the results of such analyses. These records shall remain available for a period of at least three years. This period shall be automatically extended for the duration of any litigation concerning the user or the city, or where the user has been specifically notified of a longer retention period by the director. All industrial users who discharge or propose to discharge wastewaters to the wastewater treatment system shall maintain such records of production and related factors, effluent flows, and pollutant amounts or concentrations as are necessary to demonstrate compliance with the requirements of this chapter and any applicable state or federal pretreatment standards or requirements. (b) Information and data on a user obtained from reports, questionnaires, permit applications, permits and monitoring programs and from inspection shall be available to the public or other governmental agency without restriction unless the user specifically requests and is able to demonstrate to the satisfaction of the city that the release of such information would divulge information, processes or methods of productions entitled to protection as trade secrets of the user. (c) When requested by the person furnishing a report, the portions of a report which might disclose trade secrets of secret processes shall not be made available for inspection by the public but shall be made available upon written request to governmental agencies for uses related to this chapter, the NPDES permit, state disposal system permit and/or the pretreatment programs; provided, however, that such portions of a report shall be available for use by the state or any state agency in judicial review or enforcement proceedings involving the person furnishing the report. Wastewater constituents and characteristics will not be recognized as confidential information. (d) Information accepted by the city as confidential shall not be transmitted to any government agency or to the general public by the city until and unless a ten-day notification is given to the user. (20) Pretreatment of off-site generated wastes. No industrial user may accept or treat liquid wastes from any other site for the purpose of pretreatment and discharge to the public sewer system. (21) Dilution. Except where expressly authorized by an applicable pretreatment standard, no industrial user shall increase the use of process water or in any way attempt to dilute a discharge as a partial or complete substitution for adequate treatment to achieve compliance with such standard. (22) Discharge of hazardous waste prohibition and notification. The discharge of any hazardous waste, as defined at 40 CFR 261, is prohibited. Any user who accidentally discharges any hazardous waste shall notify the POTW immediately. Also, the user shall notify the EPA regional waste management division director, the POTW, and state hazardous waste authorities, in writing, within 30 days, of any discharge into the POTW of a substance which, if otherwise disposed of, would be a hazardous waste under 40 CFR Part 261. Such notification must include the name of the hazardous waste as set forth in 40 CFR Part 261, the EPA hazardous waste number, and the type of discharge (continuous, batch, or other). (23) Reporting requirements. (a) Baseline monitoring reports. (1) Within either 180 days after the effective date of a categorical pretreatment standard, or the final administrative decision on a category determination under Tennessee Rule 0400-40-14-.06(1)(d), whichever is later, existing categorical industrial users currently discharging to or scheduled to discharge to the POTW shall submit to the director a report which contains the information listed in paragraph B, below. At least 90 days prior to commencement of their discharge, new sources, and sources that become categorical industrial users subsequent to the promulgation of an applicable categorical standard, shall submit to [the superintendent] a report which contains the information listed in paragraph B, below. A new source shall report the method of pretreatment it intends to use to meet applicable categorical standards. A new source also shall give estimates of its anticipated flow and quantity of pollutants to be discharged. (2) Users described above shall submit the information set forth below. (i) All information required in section 18-211(8). (ii) Measurement of pollutants. a. The user shall provide the information required in section 18-211(8). b. The user shall take a minimum of one representative sample to compile that data necessary to comply with the requirements of this paragraph. c. Samples should be taken immediately downstream from pretreatment facilities if such exist or immediately downstream from the regulated process if no pretreatment exists. If other wastewaters are mixed with the regulated wastewater prior to pretreatment the user should measure the flows and concentrations necessary to allow use of the combined wastestream formula in Tennessee Rule 0400-40-14-.06(5) to evaluate compliance with the pretreatment standards. Where an alternate concentration or mass limit has been calculated in accordance with Tennessee Rule 0400-40-14-.06(5) this adjusted limit along with supporting data shall be submitted to the control authority; d. Sampling and analysis shall be performed in accordance with section 18-211(17); e. The director may allow the submission of a baseline report which utilizes only historical data so long as the data provides information sufficient to determine the need for industrial pretreatment measures; f. The baseline report shall indicate the time, date and place of sampling and methods of analysis, and shall certify that such sampling and analysis is representative of normal work cycles and expected pollutant discharges to the POTW. (iii) Compliance certification. A statement, reviewed by the user's authorized representative as defined in section 18-203(4) and certified by a qualified professional, indicating whether pretreatment standards are being met on a consistent basis, and, if not, whether additional operation and maintenance (O&M) and/or additional pretreatment is required to meet the pretreatment standards and requirements. (iv) Compliance schedule. If additional pretreatment and/or O&M will be required to meet the pretreatment standards, the shortest schedule by which the user will provide such additional pretreatment and/or O&M must be provided. The completion date in this schedule shall not be later than the compliance date established for the applicable pretreatment standard. A compliance schedule pursuant to this section must meet the requirements set out in this chapter. (v) Compliance schedule progress reports. The following conditions shall apply to the compliance schedule required by 18-211(a)(2)(iv) of this chapter: a. The schedule shall contain progress increments in the form of dates for the commencement and completion of major events leading to the construction and operation of additional pretreatment required for the user to meet the applicable pretreatment standards (such events include, but are not limited to, hiring an engineer, completing preliminary and final plans, executing contracts for major components, commencing and completing construction, and beginning and conducting routine operation); b. No increment referred to above shall exceed nine months; c. The user shall submit a progress report to [the superintendent] no later than 14 days following each date in the schedule and the final date of compliance including, as a minimum, whether or not it complied with the increment of progress, the reason for any delay, and, if appropriate, the steps being taken by the user to return to the established schedule; and d. In no event shall more than nine months elapse between such progress reports to the director. (vi) Signature and report certification. All baseline monitoring reports must be certified in accordance with section 18-211(23)(a)(2) of this chapter and signed by an authorized representative as defined in section 18-203(4). (b) Periodic compliance reports. (1) All significant industrial users must, at a frequency determined by the director, submit no less than twice per year (June and December [or on dates specified by the city]) reports indicating the nature, concentration of pollutants in the discharge which are limited by pretreatment standards and the measured or estimated average and maximum daily flows for the reporting period. In cases where the pretreatment standard requires compliance with a best management practice (BMP) or pollution prevention alternative, the user must submit documentation required by the director or the pretreatment standard necessary to determine the compliance status of the user. (2) All periodic compliance reports must be signed and certified in accordance with section 18-211(23)(c) of this chapter. (3) All wastewater samples must be representative of the user's discharge. Wastewater monitoring and flow measurement facilities shall be properly operated, kept clean, and maintained in good working order at all times. The failure of a user to keep its monitoring facility in good working order shall not be grounds for the user to claim that sample results are unrepresentative of its discharge. (4) If a user subject to the reporting requirement in this section monitors any regulated pollutant at the appropriate sampling location more frequently than required by the director, using the procedures prescribed in section 18-211(17) of this chapter, the results of this monitoring shall be included in the report. (c) Certification statements. Certification of permit applications and user reports—The following certification statement is required to be signed and submitted by users submitting permit applications in accordance with this chapter; users submitting baseline monitoring reports [40 CFR 403.12 (I)]; users submitting reports on compliance with the categorical pretreatment standard deadlines [40 CFR 403.12(d)]; users submitting periodic compliance reports [40 CFR 403.12(e) and (h)]. The following certification statement must be signed by an authorized representative as defined in section 18-203(4): I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
(Ord. No. 2020-32, 2-9-2021)
Ask a question about Franklin law
Corpus searches the Franklin sections it holds and shows the ones that match, with their citations. Free, no sign-in.
