Sec. 18-307. - Required protective device.
Where the nature of use of the water supplied to a premises by the water system is such that it is deemed: (1) Impractical to provide an effective air-gap separation; (2) The owner or occupant of the premises cannot, or is not willing to, demonstrate to the director or his designated representative that the water use and protective features of the plumbing are such as to pose no threat to the safety or potability of the water; (3) The nature and mode of operation within a premises are such that frequent alterations are made to the plumbing; or (4) There is a likelihood that protective measures may be subverted, altered, or disconnected, then the director shall require the use of an approved protective device on the service line serving the premises to assure that any contamination that may originate in the customer's premises is contained therein. The protective devices shall be a reduced pressure zone type backflow preventer approved by the Tennessee Department of Environment and Conservation as to manufacture, model, and size. The method of installation of backflow protective devices shall be approved by the director prior to installation and shall comply with the criteria set forth by the Tennessee Department of Environment and Conservation. The installation shall be at the expense of the owner or occupant of the premises. Personnel of the Franklin Water System shall have the right to inspect and test the device on an annual basis or whenever deemed necessary by the director. Water service shall not be disrupted to test the device without the knowledge of the occupant of the premises. Where the use of water is critical to the continuance of normal operations or protection of life, property, or equipment, duplicate units shall be provided to avoid the necessity of discontinuing water service to test or repair the protective device. Where it is found that only one unit has been installed and the continuance of service is critical, the director shall notify, in writing, the occupant of the premises of plans to discontinue water service and arrange for a mutually acceptable time to test or repair the device. The director shall require the occupant or owner of the premises to make all repairs indicated promptly and to keep any protective device working properly. The expense of such repairs shall be borne by the owner or occupant of the premises. Repairs shall be made by qualified personnel acceptable to the director. The failure to maintain a backflow prevention device in proper working order shall be grounds for discontinuing water service to a premises. The removal, bypassing, or altering of a protective device, or the installation thereof, so as to render a device ineffective shall constitute grounds for discontinuance of water service. Water service to such premises shall not be restored until the customer has corrected or eliminated such conditions or defects to the satisfaction of the director.
(1976 Code, § 8-307; Ord. No. 2001-56, 4- -2002)
Ask a question about Franklin law
Corpus searches the Franklin sections it holds and shows the ones that match, with their citations. Free, no sign-in.