For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21-301 — Universal design and construction requirements

Municipal Code of the City of Franklin, Tennessee (Codified through Ordinance No. 2026-13, adopted June 23, 2026 (Supp. No. 30)) · Franklin Municipal Code § 21-301

Corpus is an independent public-information project, not the official City of Franklin website. Stable reference: corpuslaw.us/code/ee6f0a18-e356-4f22-ba17-905ce5e139df

Sec. 21-301. - Universal design and construction requirements.

If a person receives financial assistance from city, state or federal funds administered by the City of Franklin for the new construction of affordable, workforce and/or moderately priced housing, that person shall construct the units in accordance with all other city codes and the following requirements; (a) At least one entrance shall have a 36-inch door. (b) All interior doors shall be no less than 32 inches wide, except for a door that provides access to a closet of fewer than 15 square feet in area. (c) Each hallway shall have a width of at least 36 inches and shall be level with ramped or beveled changes at each door threshold. (d) All bathrooms shall have the walls reinforced around the toilet for potential installations of grab bars. Walls around the shower and tub shall be reinforced for potential installation of grab bars or a pre-manufactured tub and shower surround may be used which includes grab bar(s) certified to meet the ADA requirement to bear a 250-pound load. Wall reinforcements shall comply with the standards set forth in requirement 6, Reinforced Walls for Grab Bars of the Fair Housing Act Design and Construction Guidelines; Federal Register/Volume 56 No.44/Wednesday, March 6 1991/Rules and Regulations, incorporated herein for all purposes as Attachment 1. (e) Each electrical panel, light switch or thermostat shall be mounted no higher than 48 inches above the floor. Each electrical plug or other receptacle shall be at least 15 inches from the floor. (f) An electrical panel located outside the dwelling unit must be between 18 inches and 42 inches above the ground and served by an accessible route. (g) All hardware installed to open/close doors and operate plumbing fixtures shall be lever handles.

(Ord. No. 2009-22, § I, 5-12-2009)

Ask a question about Franklin law

Corpus searches the Franklin sections it holds and shows the ones that match, with their citations. Free, no sign-in.