§ 10.2 — EXTERIOR LIGHTING
Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 10, § 10.2
Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/104efdd3-05c4-4b77-b588-7108e7207dca
10.2 - EXTERIOR LIGHTING
A. Lighting Plan Required 1. A lighting plan is required for all nonresidential uses (including mixed-use), multi-family, and townhouse developments. Single-family, single-family attached and two-family dwellings are exempt from a required lighting plan but are subject to applicable lighting requirements. These lighting standards apply only to new lighting and to alterations to existing lighting, excluding routine maintenance. 2. A lighting plan must include the following: a. A plan showing all light pole locations, building-mounted lights, bollard lights, and all other lighting. b. Specifications for luminaires and lamp types, and poles, including photographs or drawings of proposed light fixtures. c. Pole and luminaire details including pole height, height of building-mounted lights, mounting height, and height of the luminaire. d. Elevations of the site including all structures and luminaires sufficient to determine the total cut off angle of all luminaires and their relationship to abutting parcels. e. For developments subject to site plan review, photometric plans that show the footcandle measurement at all lot lines may be required if the lot is adjacent to a residential district. f. Other information and data reasonably necessary to evaluate the required lighting plan. B. Lighting Standards 1. For townhouse and multi-family dwellings and non-residential developments, the maximum allowable footcandle at any lot line is one footcandle. 2. All luminaires must be of the cut off luminaire design. 3. To be considered a cut off luminaire, the cut off angle must be 75 degrees or less. A cut off luminaire must be designed to completely shield the light source from an observer 3.5 feet above the ground at any point along an abutting lot line. 4. Any freestanding cut off luminaire must be located at least 15 feet from any residential district lot line. 5. The maximum total height of a freestanding cut off luminaire is 20 feet in a nonresidential district, and 15 feet in a residential district. 6. All outdoor luminaires must be adequately shielded. 7. Outdoor lighting fixtures closer to the lot line than the mounting height of the fixture, measured perpendicular to the lot line, adjacent to residential areas, must have internal house-side shields. 8. Flood or spot lamps must be aimed down no higher than 45 degrees to the horizontal (halfway between straight down and straight to the side) when the source is visible from any adjacent residential property. CUT OFF LUMINAIRE  C. Exceptions to Lighting Standards 1. Luminaires used for public roadway illumination or installed by a utility to light public rights-of-way are not controlled by this Code. 2. All temporary emergency lighting required by public safety agencies, other emergency services, or construction are exempt from the requirements of this Code. 3. Because of their unique requirements for nighttime visibility and limited hours of operation, outdoor recreational fields (public or private) such as, but not limited to, football fields, soccer fields, baseball fields, softball fields, tennis courts, driving ranges, and other similar uses are exempt from the requirements of item B above and subject to the following: a. Recreational fields are permitted a total luminaire height of 65 feet in any district. Luminaires greater than 65 feet in total height may only be approved by special use permit. b. All lighting must be directed onto the field. c. The recreational field lighting must be extinguished 45 minutes following the end of the event. d. Lighting must comply with item B above to facilitate patrons leaving the facility, cleanup, nighttime maintenance, and other closing activities. 4. Holiday and seasonal lighting designs are exempt from the requirements of this Code. 5. Certain temporary uses may use lighting that does not meet the requirements of this section. When such temporary uses are allowed, approval of the lighting plan is required as part of the temporary use permit. 6. River navigation lighting used exclusively for river navigation and safety purposes are exempt from the requirements of this Code. D. Prohibited Lighting 1. Flickering or flashing lights are prohibited. 2. Searchlights, laser source lights, or any similar high intensity lights are prohibited. 3. Neon or LED lighting to outline doors, windows, architectural features, and building facades is prohibited. 4. Any light fixture that can be confused with or construed as a traffic control device is prohibited.
(Ord. No. O-87-2020, § 1, 5-19-20; Ord. No. O-143-2025, § 1, 11-25-25)
Ask a question about Knoxville law
Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.