For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11.7 — ACCESS AND DRIVEWAY DESIGN

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 11, § 11.7

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/1e8ce088-082f-4265-be3d-f83c40106ec8

11.7 - ACCESS AND DRIVEWAY DESIGN

These regulations are applicable in zoning districts without access and driveway requirements specific to the zoning district. If the district specifically requires access and driveway design, those requirements control. The Department of Engineering is authorized to develop and implement such policies and procedures as may be necessary and desirable to control the design and construction of driveways that are consistent with this Code. A. The number of driveways on a given street or access easement is based on the following: 1. Typical developments per Table 11-5: Maximum Number of Driveways for Lot Frontages: Table 11-5: Maximum Number of Driveways for Lot Frontages | Lot Frontage | Maximum Number of Driveways Less than 150 feet | 1 For single-family dwellings with lot frontages greater than 75', a circular driveway is allowed 150 feet—450 feet | 2 Greater than 450 feet—600 feet | 3 Greater than 600 feet—750 feet | 4 Greater than 750 feet | Determined by Department of Engineering 2. Gas stations and establishments where services are normally provided to customers without leaving their vehicles may have two driveways. 3. Projects required to prepare a Traffic Impact Study are considered individually based on the recommendation of the study and the approval of the Department of Engineering. 4. Boulevard driveways (with raised median separation), one way driveways, and right-in/right-out driveway pairs will be considered one driveway 5. The Department of Engineering may impose other access and driveway requirements as necessary based on specific site conditions. B. The minimum distance between a driveway and the intersecting street is described in Table 11-6: Corner Clearance Requirements. Table 11-6: Corner Clearance Requirements | | | Classification of Intersecting Street | Classification of Street to be Accessed | | Classification of Intersecting Street | Arterial | Collector | Local Arterial | 200' | 150' | 100' Collector | 150' | 100' | 50' Local | 100' | 50' | 50' CORNER CLEARANCE ![Figure: AppB-11-7B.png](https://figures.74-208-44-221.nip.io/knoxville/497059/cebaa0ad5bfd67c329455834a82eec839bc7b6f6d8b49f04a4f84cfeacc4756e-AppB-11-7B.png) 1. If the required distance cannot be met due to lot size or other constraint as verified by the Department of Engineering, the driveway must be located as far as possible from the intersecting street. 2. All driveways in a development must be separated by a minimum distance equal to the width of the wider driveway. 3. No curb cut may encroach on the frontage of adjacent property without the written consent of the owner for such encroachment, except where a joint use driveway with the adjacent property is established at the request of both owners. C. Table 11-7: Driveway Width and Curb Cut Length Standards provides minimum and maximum driveway widths and curb cut lengths. Table 11-7: Driveway Width and Curb Cut Length Standards | | | | | Driveway Dimensions | | Length of Curb Cut | Lot Frontage (feet) | Min. | Max. | Min. | Max. Single-Family, Single-Family Attached, Two-Family, & Townhouse: By Lot Width | | | | 50 feet or less | 10' | 18' | 15' | 24' > 50—74 | 10' | 20' | 15' | 26' Greater than 74 | 10' | 25' | 15' | 32' A circular driveway can be no wider than 18' | | | | Other Development | | | | Land Use: Uses serving a substantial number of large trucks (5/day or 25/week) | 20' | 40' | 60' | 90' Land Use: All other | 20' | 30' | 25' | 60' 1. Gas stations may have driveways up to 40 feet wide. 2. Boulevard driveways (with raised median separation), one way driveways, and right-in/right-out driveway pairs are not subject to Table 11-7 and will be reviewed on a case-by-case basis by the Department of Engineering. 3. Access to cell towers, electrical substations, pump stations, etc., defer to the Department of Engineering's Utility Driveway standards. 4. Major traffic generators will be considered as individual cases and are not subject to Table 11-7. A major traffic generator is defined as any facility that is required by this Article to provide 400 or more parking spaces. 5. On state roads, adjustments to the dimensions in Table 11-7 may be granted based on Tennessee Department of Transportation specifications. D. When a change in use, redevelopment, or alteration of any land or building makes any or all of the driveways unnecessary or noncompliant, the owner of the property must, at their expense, replace all necessary curbs, gutters, sidewalks, and landscape to a condition consistent with current City of Knoxville standards.

(Ord. No. O-87-2020, § 1, 5-19-20; Ord. No. O-96-2022, § 1, 7-26-22; Ord. No. O-143-2025, § 1, 11-25-25)

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.