Sec. 12-32. - Permit procedures.
Application for a development permit shall be made to the ordinance administrator on forms furnished by the department prior to any development activity. The development permit may include, but is not limited to, the following: plans in duplicate drawn to scale, showing the nature, location, dimensions, and elevations of the area in question; existing or proposed structures, earthen fill placement, storage of materials or equipment, and drainage facilities. Specifically, the following information is required: (1) Application stage. a. Elevation in relation to mean sea level of the proposed lowest floor, including basement, of all buildings where base flood elevations are available, or to the required height above the highest adjacent grade when applicable under this chapter. b. Elevation in relation to mean sea level to which any non-residential building will be floodproofed, where base flood elevations are available, or to the required height above the highest adjacent grade when applicable under this chapter. c. A FEMA floodproofing certificate from a Tennessee-registered professional engineer or architect that the proposed nonresidential floodproofed building will meet the floodproofing criteria in article II, section 12-32(2). d. Description of the extent to which any watercourse will be altered or relocated as a result of proposed development. e. In order to determine if improvements or damage meet the substantial improvement or substantial damage criteria, the applicant shall provide to the ordinance administrator a detailed cost to repair all damages and/or cost of improvements which includes the complete costs associated with all types of work necessary to repair or improve a building. These include the costs of all materials, labor, and other items necessary to perform the proposed work. These must be in the form of: 1. An itemized costs of materials, and labor, or estimates of materials and labor that are prepared by licensed contractors or professional construction cost estimators; 2. Building valuation tables published by building code organizations and cost-estimating manuals and tools available from professional building cost-estimating services; 3. A qualified estimate of costs that is prepared by the local official using professional judgement and knowledge of local and regional construction costs; or 4. A detailed cost estimate provided and prepared by the building owner. This must include as much supporting documentation as possible (such as pricing information from lumber companies, plumbing and electrical suppliers, etc.). In addition, the estimate must include the value of labor, including the value of the owner's labor. (2) Construction stage. Within AE and shaded X zones, where base flood elevation data is available, any lowest floor certification made relative to mean sea level shall be prepared by, or under the direct supervision of, a Tennessee-registered land surveyor and certified by same. The ordinance administrator shall record the elevation of the lowest floor on the development permit. The elevation of the lowest floor shall be determined as the measurement of the lowest floor of the building relative to the highest adjacent grade. When floodproofing is utilized for a non- residential building, said certification shall be prepared by, or under the direct supervision of, a Tennessee-registered professional engineer or architect and certified by same. For all new construction and substantial improvements, the permit holder shall provide to the ordinance administrator an as-built certification of the lowest floor elevation or floodproofing level upon the completion of the lowest floor or floodproofing. Within approximate A zones, where flood elevation data is not available, the elevation of the lowest floor shall be determined as the measurement of the lowest floor of the building relative to the highest adjacent grade. The ordinance administrator shall record the elevation of the lowest floor on the development permit. Any lowest floor certification made relative to mean sea level shall be prepared by, or under the direct supervision of a Tennessee-registered land surveyor and certified by same. When floodproofing is utilized for a non-residential building, said certification shall be prepared by, or under the direct supervision of, a Tennessee-registered professional engineer or architect and certified by same. Any work undertaken prior to submission of the certification shall be at the permit holder's risk. The ordinance administrator shall review the above-referenced certification data. Deficiencies detected by such review shall be corrected by the permit holder immediately and prior to further work being allowed to proceed. Failure to submit the certification or failure to make said corrections required hereby, shall be cause to issue a stop-work order for the project. (3) Finished construction. Upon completion of construction, a FEMA elevation certificate which depicts all finished construction elevations is required to be submitted to the ordinance administrator. If the project includes a floodproofing measure, a FEMA floodproofing certificate is required to be submitted by the permit holder to the ordinance administrator. An operation and maintenance plan must be provided along with the floodproofing certificate.
(Ord. No. O-112-2013, § 1, 6-25-13; Ord. No. O-170-2020, § 3, 11-17-20)
Ask a question about Knoxville law
Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.