For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-55.2 — Amendments

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Code of Ordinances § 6-55.2

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/076d9a2d-85c5-44f1-bc7f-b0282ca01495

Sec. 6-55.2. - Amendments.

Amend Chapter 1, Scope and Administration, as follows: Delete the text of Section 101.3 Scope in its entirety and substitute the following: This Code shall apply for use on a voluntary basis to the design, construction, addition, alteration, change of occupancy, relocation, replacement, repair, equipment, building site, maintenance, removal and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures and to the site on which the building is located. Additions, alterations or repairs to any structure shall conform to the requirements for a new structure without requiring the existing structure to comply with all of the requirements of this Code, unless otherwise stated. Additions, alterations or repairs shall not cause an existing structure to become unsafe or adversely affect the performance of the building. Quality control of materials and workmanship is not within the scope of this Code except as related to the purposes stated herein. Occupancy classifications shall be determined in accordance with the International Building Code. Amend Section 103 to rename the section "Duties and Powers of the Building Official." Delete the text of Section 107.1 Fees in its entirety and substitute the following: The fees for work shall be as identified in the Fee Schedule, as adopted by City Council resolution. Delete the text of Section 110 Means of Appeals in its entirety and substitute the following: 110.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code, there shall be and is hereby created a Construction Appeals Board (hereinafter referred to as the "board"). The board shall be appointed by the Mayor and shall hold office at his or her pleasure. The board may adopt rules of procedure for conducting business. 110.2 Limitations on authority. A person shall have the right to appeal a decision of the building official to the board. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply or an equally good or better form of construction is proposed. The board shall have no authority to waive requirements of this code. 110.3 Application. The application for appeal shall be filed on a form obtained from the building official within thirty (30) days from the calendar date the decision is rendered by the building official. Application for appeal must be filed within ten (10) days prior to the monthly meeting date. In the case of a building or structure that, in the opinion of the building official, is unsafe or dangerous, the building official may, in the order, limit the time for such appeals to a shorter period. 110.4 Qualifications. The board shall consist of nine (9) members appointed by the Mayor and who are qualified by experience and training to pass on matters pertaining to building construction and are not employees of the jurisdiction. This board shall consist of the following: 1. (1) State Registered Architect 2. (1) Contractor with a Building Contractor's License 3. (1) Person with experience, training and full knowledge of fire service and/or knowledge of the applicable fire prevention codes as adopted by the City who shall have had at least 10 years' experience within the field represented 4. Consumer Representative 5. State Licensed Mechanical Engineer 6. Licensed Mechanical Contractor 7. Licensed Plumbing Contractor 8. State Licensed Electrical Engineer 9. Licensed Electrical Contractor 110.5 Terms. Board members shall be appointed to staggered terms of five (5) years each, provided that members may be appointed to terms shorter than five (5) years when necessary to provide for staggered terms. Vacancies shall be filled for an unexpired term in the manner in which original appointments are required to be made. Board members may continue to serve until reappointed or replaced. Official misconduct, neglect of duty, or continued absence of any member from required meetings of the Board shall, at the discretion of the Mayor, render any such member subject to immediate removal from office. 110.6 Quorum and Voting. A simple majority of the board shall constitute a quorum. In varying any provision of this code, the affirmative votes of the majority present, but not less than three affirmative votes, shall be required. If the board's vote results in a tie, the motion shall fail. In the event of a tied vote, the board shall not be required to continue the item for consideration at a future meeting. A board member shall not act in a case in which said member has a personal, financial, or other interest and shall recuse himself or herself from all participation when the matter is formally presented to the Board for consideration. Any board member who has been recused shall immediately leave the room or shall be seated with the other members of the public who are present. The recused board member shall not give testimony in favor or in opposition of any application being considered by the board. Once the matter has been concluded, the member shall be reseated with the board. 110.7 Secretary of the Board. The building official or designee shall act as secretary of the Board and shall make a detailed record of all of its proceedings, which shall set forth the reasons for its decision, the vote of each member, the absence of a member, and any failure of a member to vote. Amend Chapter 3 Jurisdictional Requirements and Life Cycle Assessment as follows: Delete Table 302.1 Requirements Determined by The Jurisdiction in its entirety and substitute with the following: _____ TABLE 302.1 REQUIREMENTS DETERMINED BY THE JURISDICTION Section | Section Title or Description and Directives | Jurisdictional Requirements CHAPTER 1. SCOPE | | 101.3 Exception 1.1 | Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories in height above grade plane with a separate means of egress, their accessory structures, and the site or lot upon which these buildings are located, shall comply with ICC 700. | Yes 101.3 Exception 1.2 | Group R-3 residential buildings, their accessory structures, and the site or lot upon which these buildings are located, shall comply with ICC 700. | Yes 101.3 Exception 1.3 | Group R-2 and R-4 residential buildings four stories or less in height above grade plane, their accessory structures, and the site or lot upon which these buildings are located, shall comply with ICC 700. | Yes CHAPTER 4. SITE DEVELOPMENT AND LAND USE | | 402.2.1 | Flood hazard area preservation, general | Yes 402.2.2 | Flood hazard area preservation, specific | Yes 402.3 | Surface water protection | Yes 402.5 | Conservation area | Yes 402.7 | Agricultural land | Yes 402.8 | Greenfield sites | Yes 407.4.1 | High-occupancy vehicle parking | Yes 407.4.2 | Low-emission, hybrid and electric vehicle parking | Yes 409.1 | Light pollution control | Yes CHAPTER 5. MATERIAL RESOURCE CONSERVATION AND EFFICIENCY | | 503.1 | Minimum percentage of waste material diverted from landfills | 50% CHAPTER 6. ENERGY CONSERVATION, EFFICIENCY AND CO 2 e EMISSION REDUCTION | | 302.1, 302.1.1, 602.1 | zEPI of Jurisdictional Choice - The jurisdiction shall indicate a zEPI of 46 or less in each occupancy for which it intends to require enhanced energy performance. | No requirement 604.1 | Automated demand response infrastructure | Yes CHAPTER 7. WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY | | 702.7 | Municipal reclaimed water | No CHAPTER 8. INDOOR ENVIRONMENTAL QUALITY AND COMFORT | | 804.2 | Post-Construction Pre-Occupancy Baseline IAQ Testing | Yes 807.1 | Sound transmission and sound levels | Yes CHAPTER 10. EXISTING BUILDINGS | | 1007.2 | Evaluation of existing buildings | Yes 1007.3 | Post Certificate of Occupancy zEPI, energy demand, and CO 2 e emissions reporting | Yes

(Ord. No. O-27-2014, § 1, 2-4-14; Ord. No. O-151-2014, § 1, 6-24-14; Ord. O-19-2016, § 1, 2-2-16; Ord. No. O-42-2018, § 1, 3-27-18; Ord. No. O-38-2022, § 1, 3-22-22; Ord. No. O-125-2024, § 2, 10-29-24)

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.